• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6343-0AA34-0MB6 OP 177B
    Awaiting product image

    Siemens 6AV6343-0AA34-0MB6 OP 177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6343-0AA34-0MB6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6343-0AA34-0MB6 is an Operator Panel (OP 177B) belonging to the SIMATIC HMI series, designed for machine-level visualization and operator control tasks. This unit provides a monochrome display interface for process monitoring and control in industrial automation environments. It is part of Siemens' established SIMATIC HMI portfolio and is configured for use with SIMATIC S7 and other compatible controller families.

    The OP 177B features a 5.7-inch STN monochrome display with a resolution of 320 x 240 pixels and supports both touch and key-based operation through its integrated membrane keypad. It includes MPI/PROFIBUS DP and RS-422/RS-485 communication interfaces, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel is configured with 512 KB user memory for project data and runs on the WinCC flexible runtime environment, supporting alarm management, recipe handling, and trend display functions.

    The OP 177B is widely deployed in machine building, packaging, food and beverage processing, and general manufacturing applications where a compact, robust operator interface is required. Its panel-mount design and IP65 front protection rating make it suitable for integration into control cabinets and machine enclosures exposed to dust and water spray. The combination of keypad and touch operation provides flexibility for environments where gloved operation or harsh conditions are a consideration.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN monochrome
    Display Resolution 320 x 240 pixels (QVGA)
    Touch Technology Resistive touch + membrane keypad
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 8 W
    Communication Interface MPI/PROFIBUS DP, RS-422/RS-485
    User Memory 512 KB
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mount
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI OP 177B

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI/PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to the PLC was interrupted during runtime operation.
    Inspect physical cabling for damage or loose connectors. Check for address conflicts on the MPI/PROFIBUS network. Restart both the HMI and PLC if the connection does not recover automatically.
    Event ID: 20000
    Project download error. The project could not be transferred to the HMI panel successfully.
    Verify the PC-to-HMI transfer cable is correctly connected. Confirm the panel is in transfer mode before initiating download. Check WinCC flexible project for compilation errors before transfer.
    Event ID: 40000
    System memory low. Available runtime memory is insufficient for the current project.
    Reduce the number of active alarms, recipes, or trend buffers in the project. Optimize the project in WinCC flexible to reduce memory usage and re-download.
    Event ID: 50000
    Internal device error or hardware fault detected on the panel.
    Perform a panel reset by cycling power. If the error persists, back up the project and perform a factory reset. Contact Siemens technical support or arrange for unit repair if the fault remains.
    Event ID: 60000
    Configuration error detected. The loaded project is incompatible with the current firmware version of the panel.
    Update the panel firmware to the version required by the WinCC flexible project, or recompile the project using a compatible version of WinCC flexible and re-download.
    Event ID: 70000
    Alarm buffer overflow. The number of pending alarms has exceeded the configured buffer limit.
    Acknowledge and clear active alarms on the panel. Review alarm configuration in WinCC flexible to increase buffer size or implement alarm suppression logic in the PLC program.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 177B (6AV6343-0AA34-0MB6)?

    The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports a range of third-party controllers through RS-422/RS-485 serial communication using appropriate drivers in WinCC flexible.

    What software is required to program and configure this HMI panel?

    The OP 177B is configured using Siemens WinCC flexible software. The project is compiled in WinCC flexible and downloaded to the panel via a PC adapter cable or MPI/PROFIBUS connection.

    What is the supply voltage for the 6AV6343-0AA34-0MB6?

    The panel operates on 24 V DC. Ensure the power supply is within the specified tolerance range to avoid operational issues.

    Does the OP 177B support recipe and alarm management functions?

    Yes, the OP 177B supports recipe management, alarm logging, and trend display functions within the WinCC flexible runtime environment, subject to the available user memory of 512 KB.

    What is the front panel protection rating of this unit?

    The front panel of the OP 177B carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for integration into machine enclosures.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for blown internal fuses or damaged power input wiring.

    Ensure the supply voltage is stable at 24 V DC within the specified tolerance. Replace any blown fuses and inspect the power connector for corrosion or loose contacts. If the internal power supply is faulty, the unit will require repair or replacement.

    HMI panel fails to communicate with the connected SIMATIC PLC

    Verify the MPI or PROFIBUS DP cable is correctly wired and terminated at both ends. Check the network address and baud rate configured in the HMI project against the PLC settings.

    Correct any address conflicts or baud rate mismatches in the WinCC flexible project and re-download. Replace the communication cable if continuity testing reveals a fault. Ensure termination resistors are active only at the physical ends of the network.

    Touchscreen does not respond or responds inaccurately to input

    Check whether the membrane keypad functions correctly as an alternative input method. Inspect the touchscreen surface for physical damage, contamination, or excessive wear.

    Clean the touchscreen surface with a soft, dry cloth. Perform a touchscreen recalibration through the panel's system settings menu. If the touch layer is physically damaged, the panel will require professional repair or display replacement.

    Project download fails or transfer is interrupted

    Confirm the panel is set to transfer mode before initiating the download from WinCC flexible. Check the PC adapter cable connection and driver installation on the engineering PC.

    Restart the panel in transfer mode and retry the download. Reinstall the PC adapter driver if communication is not established. Verify the WinCC flexible project compiles without errors before attempting transfer.

    Panel displays repeated or persistent alarm messages after startup

    Review the PLC program logic to determine whether the alarm trigger conditions are genuinely active or caused by a configuration error. Check the alarm buffer in WinCC flexible for overflow conditions.

    Acknowledge and clear alarms from the panel. Investigate and resolve the underlying process condition triggering the alarms in the PLC program. If alarms are spurious, review and correct the alarm tag configuration in the WinCC flexible project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart