Siemens 6AV6343-0AA34-0CB6 OP 177B
The Siemens 6AV6343-0AA34-0CB6 is an OP 177B operator panel belonging to the SIMATIC HMI family, designed for machine-level human-machine interface applications. This unit provides a monochrome display with keypad-based operation and is part of the Comfort/Mobile Panel predecessor generation used extensively in industrial automation environments. The OP 177B serves as a compact, robust operator panel for visualizing process data and controlling machinery directly at the machine level.
The 6AV6343-0AA34-0CB6 features a 5.7-inch STN monochrome display with a resolution of 320 x 240 pixels and an integrated membrane keypad for operator input. It supports communication via MPI, PROFIBUS DP, and RS-422/RS-485 interfaces, enabling integration with SIMATIC S7-200, S7-300, and S7-400 PLCs as well as third-party controllers. The panel is configured using WinCC flexible software and offers onboard flash memory for project storage, along with support for recipe management and alarm logging functions.
The OP 177B is widely deployed in manufacturing, packaging, and process industries where a cost-effective, reliable operator interface is required at the machine level. Its compatibility with the broad SIMATIC PLC portfolio makes it suitable for retrofitting existing S7-based installations as well as new machine builds. The panel's compact form factor and keypad operation make it appropriate for environments where touchscreen operation is not practical or desired.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN monochrome LCD |
| Display Resolution | 320 x 240 pixels (QVGA) |
| Display Colors | Monochrome (blue/white) |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 8 W |
| Communication Interface | MPI, PROFIBUS DP, RS-422/RS-485 |
| Configuration Software | WinCC flexible 2008 or later |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front panel) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI OP 177B |
Common Error Codes & System Events
- Event ID: 10000
- Configuration error detected on startup; the project loaded on the panel contains configuration inconsistencies.
Reload the project using WinCC flexible. Verify the project was compiled without errors before transferring. - Event ID: 20000
- Communication error with the configured PLC or controller; connection cannot be established.
Check MPI/PROFIBUS cable connections and termination resistors. Verify the PLC address and baud rate settings match the panel configuration. - Event ID: 40000
- Tag read/write error; the panel cannot access a configured PLC tag or data block.
Verify the tag address and data block exist in the PLC program. Check PLC is in RUN mode and communication link is active. - Event ID: 50000
- Flash memory write error; the panel was unable to save data (e.g. recipe or alarm log) to internal flash memory.
Check available flash memory capacity. Delete unused recipes or logs. If persistent, the internal flash memory may require service or replacement. - Event ID: 60000
- Licence or system software error; the runtime software on the panel has detected an integrity issue.
Perform a factory reset and reload the WinCC flexible runtime and project. Ensure the correct runtime version is installed for the panel firmware. - Event ID: 70000
- Power supply undervoltage detected; the 24 V DC supply voltage has dropped below the permissible operating range.
Measure the supply voltage at the panel connector. Ensure the power supply output is stable at 24 V DC and the cable cross-section is adequate for the load. - Event ID: 80000
- Operating system error or watchdog timeout; the panel runtime has stopped responding.
Perform a controlled restart of the panel. If the fault recurs, reload the runtime software and project. Check for hardware faults on the main board.
Frequently Asked Questions
Which PLCs are compatible with the OP 177B (6AV6343-0AA34-0CB6)?
The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It also supports communication with a range of third-party controllers through its RS-422/RS-485 serial interface using configurable drivers in WinCC flexible.
What software is used to configure and program the OP 177B?
The OP 177B is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are compiled in WinCC flexible and transferred to the panel via MPI, PROFIBUS, or a USB/serial connection.
What is the front panel protection rating of the OP 177B?
The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present.
Does the OP 177B support recipe management and alarm logging?
Yes, the OP 177B supports recipe management and alarm logging functions. Data is stored in the panel's internal flash memory, and the number of records is limited by available memory capacity.
What is the supply voltage required for the OP 177B?
The OP 177B requires a 24 V DC supply voltage. The power consumption is typically up to 8 W, and the supply should be a regulated SELV (Safety Extra Low Voltage) source.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel's power connector. Check that the supply is within the permissible range and that the connector is fully seated.
Restore the supply voltage to 24 V DC if it is out of range. If the supply is correct and the display remains blank, the internal power supply board or backlight inverter may be faulty and require replacement.
Panel displays 'No connection to PLC' or communication errors at startup
Verify the MPI or PROFIBUS cable is correctly connected and terminated at both ends. Check that the PLC address and baud rate configured in WinCC flexible match the actual PLC settings.
Correct any address or baud rate mismatches in the WinCC flexible project and retransfer. Replace the communication cable if damaged. Ensure PROFIBUS termination resistors are enabled only at the physical ends of the bus.
Touchscreen or keypad inputs are not responding correctly
For keypad issues, inspect the membrane keypad connector on the main board for damage or poor contact. Test each key systematically in the panel's service/test mode if available.
Reseat the keypad ribbon connector. If individual keys are unresponsive due to membrane damage, the keypad assembly should be replaced. For configuration-related input issues, reload the project from WinCC flexible.
Project transfer fails or panel cannot be reached during download
Check the transfer cable connection (MPI or serial). Verify the panel is set to 'Transfer' mode. Confirm the PC interface settings in WinCC flexible match the physical connection type and baud rate.
Set the panel to Transfer mode via the Start Center menu. Ensure the correct PC adapter (e.g. PC Adapter USB) is selected in WinCC flexible. Replace the transfer cable if communication cannot be established.
Panel restarts repeatedly or shows a watchdog/runtime error
A recurring restart typically indicates a corrupted runtime or project file, or a hardware fault on the main board. Check the event log for specific event IDs if the panel boots far enough to display them.
Perform a factory reset via the panel's Start Center (loader) menu, then reload the WinCC flexible runtime and project. If restarts continue after a clean reload, the main board may require repair or replacement.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page