• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6343-0AA14-0CB0 OP 177B
    Awaiting product image

    Siemens 6AV6343-0AA14-0CB0 OP 177B

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6343-0AA14-0CB0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6343-0AA14-0CB0 is an OP 177B operator panel belonging to the SIMATIC HMI series, designed for machine-level human-machine interface applications. This unit provides a monochrome STN display and is part of the comfort-oriented mid-range panel lineup from Siemens, offering reliable process visualization and operator control. The OP 177B is engineered for integration into industrial control cabinets and machine fronts where robust, straightforward HMI functionality is required.

    The 6AV6343-0AA14-0CB0 features a 5.7-inch STN monochrome display with a resolution of 320 x 240 pixels (QVGA), supporting text and graphics-based visualization. The panel includes a membrane keypad with function keys, numeric keys, and system keys for operator input without requiring a touchscreen. It communicates via MPI, PROFIBUS DP, and RS-422/RS-485 interfaces, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs as well as third-party controllers. The unit operates on 24 V DC supply and is configured using Siemens WinCC flexible engineering software.

    The OP 177B is widely deployed in manufacturing automation, packaging machinery, material handling systems, and process control installations where a compact, keypad-operated HMI panel is preferred over touchscreen solutions. Its compatibility with the broad SIMATIC S7 PLC family makes it a standard choice for machine builders and system integrators working within Siemens automation architectures. The panel's robust membrane keypad design is particularly suited to environments where gloves are worn or where touchscreen operation is impractical.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN monochrome LCD
    Display Resolution 320 x 240 pixels (QVGA)
    Display Colors Monochrome (blue/white)
    Input Method Membrane keypad (function keys, numeric keys, system keys)
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 9 W
    Communication Interface MPI, PROFIBUS DP, RS-422/RS-485
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Engineering Software WinCC flexible 2005 or higher

    Common Error Codes & System Events

    Event ID: 10000
    Configuration error detected on startup — the loaded project is incompatible with the panel type or firmware version.
    Re-transfer the correct WinCC flexible project compiled for the OP 177B. Verify firmware version compatibility between the project and the panel.
    Event ID: 10001
    Communication link to the PLC cannot be established or has been lost.
    Check MPI/PROFIBUS cable connections and termination resistors. Verify the PLC address and baud rate settings match the HMI project configuration.
    Event ID: 20000
    Internal flash memory error — project data could not be read or is corrupted.
    Perform a factory reset and re-transfer the project via WinCC flexible. If the error persists, the internal flash memory may require replacement.
    Event ID: 40000
    Operator panel has detected a system software (firmware) fault.
    Update the panel firmware using ProSave or WinCC flexible. Perform a complete power cycle after the update.
    Event ID: 50000
    Tag update error — a process variable (tag) could not be read from or written to the PLC.
    Verify the tag address in the WinCC flexible project matches the actual PLC data block or memory address. Check PLC program for address conflicts.
    Event ID: 60000
    Recipe data error — recipe records could not be read from or written to the configured storage location.
    Check available memory on the panel. Verify recipe configuration in WinCC flexible. Re-transfer the project if recipe structure has changed.
    Event ID: 70000
    Alarm buffer overflow — the number of pending alarms exceeds the panel's alarm buffer capacity.
    Acknowledge and clear active alarms. Review the alarm configuration in WinCC flexible to reduce simultaneous alarm triggers or increase the buffer size setting.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 177B (6AV6343-0AA14-0CB0)?

    The OP 177B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP. It also supports communication with third-party controllers via RS-422/RS-485 using standard protocols such as Modbus RTU.

    What software is required to configure and program the OP 177B?

    The OP 177B is configured using Siemens WinCC flexible 2005 or later versions. Projects are transferred to the panel via MPI cable, PROFIBUS, or a PC/PPI cable depending on the interface used.

    What is the supply voltage for the 6AV6343-0AA14-0CB0?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to avoid operational faults.

    Does the OP 177B support touchscreen input?

    No, the OP 177B uses a membrane keypad for operator input and does not have a touchscreen. Operator interaction is performed via dedicated function keys, numeric keys, and system keys.

    What is the front panel protection rating of the OP 177B?

    The front panel of the OP 177B carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for blown internal fuse or wiring fault at the supply terminals.

    Restore correct 24 V DC supply within specified tolerance. Replace the internal fuse if blown. If the display backlight has failed, the backlight unit or the panel itself may require replacement.

    Panel displays 'No connection to PLC' or communication error on startup

    Check the MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Verify bus termination is correctly applied at both ends of the network segment. Confirm the PLC address and baud rate in the HMI project match the physical network settings.

    Correct any wiring faults, replace damaged cables, and ensure bus termination resistors are properly installed. Adjust the PLC address and baud rate in the WinCC flexible project and re-transfer if necessary.

    Project transfer from PC to panel fails

    Verify the transfer cable type and connection (MPI or PC/PPI cable). Check that the panel is set to transfer mode (accessible via the Start Center or Control Panel on the device). Confirm the COM port settings in WinCC flexible match the physical connection.

    Set the panel to transfer mode via the Start Center. Use a compatible Siemens MPI or PC/PPI cable. Adjust COM port and baud rate settings in WinCC flexible to match the cable and panel configuration.

    Function keys do not respond or produce incorrect actions

    Check the keypad membrane for physical damage or contamination beneath the keys. Verify the function key assignments in the WinCC flexible project are correctly configured and the project has been fully transferred.

    Clean the keypad surface and inspect for membrane damage. If keys are physically damaged, the membrane keypad assembly requires replacement. Re-transfer the project if key assignments appear incorrect in software.

    Panel repeatedly restarts or enters a boot loop

    This may indicate a corrupted project file or a firmware fault. Attempt to access the Start Center during boot by pressing the appropriate key combination. Check if the panel can boot without a loaded project.

    Perform a factory reset via the Start Center or using ProSave. Re-flash the panel firmware using ProSave, then re-transfer the WinCC flexible project. If the issue persists after firmware update and project re-transfer, the panel hardware may be faulty.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart