Siemens 6AV6341-1EC04-0BY0 OP 77B
€ 1.995,00
The Siemens 6AV6341-1EC04-0BY0 is an OP 77B operator panel belonging to the SIMATIC HMI Basic Panels product family. It is designed for straightforward machine-level operator control and monitoring tasks, providing a compact and cost-effective human-machine interface solution. This unit features a monochrome display and membrane keypad, making it suitable for applications where a simple, robust interface is required.
The OP 77B panel communicates via MPI and PROFIBUS DP interfaces, enabling direct integration with SIMATIC S7-200, S7-300, and S7-400 PLCs without additional hardware. It is configured using WinCC flexible software, which allows the creation of screens, alarms, and recipes. The panel operates on 24 V DC supply voltage and is rated IP65 on the front face, providing protection against dust and water ingress in industrial environments. Onboard memory supports the storage of project data, alarm logs, and recipe data.
The OP 77B is widely deployed in machine building, conveyor systems, packaging machinery, and general factory automation where a simple text or basic graphic display is sufficient. Its compact panel-mount form factor and compatibility with the broad SIMATIC S7 PLC range make it a practical choice for OEMs and system integrators. The rugged membrane keypad and sealed front face allow reliable operation in dusty or humid production environments.
Technical Specifications
| Display Type | Monochrome STN LCD |
|---|---|
| Display Size | 4 inch |
| Display Resolution | 320 x 240 pixels |
| Display Colors | Monochrome (blue/white) |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 6 W |
| Communication Interface | MPI, PROFIBUS DP |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Mounting | Panel mounting |
| Configuration Software | WinCC flexible 2005 or higher |
| Series/Product Family | SIMATIC HMI Basic Panels / OP 77B |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the HMI panel and the connected PLC. The panel cannot establish or maintain a connection to the configured controller.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the project configuration. Ensure the PLC is powered and in RUN mode. - Event ID: 10001
- Connection to PLC interrupted during runtime. The panel lost communication with the controller after an initial successful connection.
Inspect cable integrity and connector seating. Check for electromagnetic interference sources near the communication cable. Verify PLC is still operational and has not faulted. - Event ID: 20000
- Project download error. The project could not be transferred successfully from the configuration PC to the panel.
Verify the PC-to-panel connection cable is functional. Ensure WinCC flexible version is compatible with the panel firmware. Check available memory on the panel and delete old projects if necessary. - Event ID: 40000
- System memory low. The panel's available memory for runtime data, alarms, or recipes is running low.
Reduce the number of stored alarm entries or recipe data sets. Optimize the project to reduce memory usage and re-download the project. - Event ID: 50000
- Panel firmware version mismatch. The firmware on the panel is incompatible with the downloaded project.
Update the panel firmware using ProSave or WinCC flexible to a version compatible with the project. Re-download the project after firmware update. - Event ID: 60000
- Tag read/write error. A configured tag could not be read from or written to the connected PLC.
Verify the tag address in the project matches the actual PLC data block or memory address. Check PLC program to ensure the address is accessible and not write-protected. - Event ID: 70000
- Recipe data error. An error occurred during reading or writing of recipe data.
Check recipe configuration in WinCC flexible. Verify that the recipe tag addresses are valid and accessible in the PLC. Re-download the project if the recipe structure has been modified.
Frequently Asked Questions
Which PLCs are compatible with the OP 77B panel?
The OP 77B is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 via the PPI protocol.
What software is used to configure the OP 77B?
The OP 77B is configured using Siemens WinCC flexible 2005 or later versions. Projects are downloaded to the panel via an MPI connection or a dedicated PC/PPI cable for S7-200 applications.
What is the supply voltage for the 6AV6341-1EC04-0BY0?
The panel requires a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to guarantee reliable operation.
What is the front panel protection rating of the OP 77B?
The front face of the OP 77B is rated IP65, providing full protection against dust ingress and protection against low-pressure water jets. The rear of the unit is rated IP20.
Can the OP 77B display graphical images or only text?
The OP 77B supports basic graphics in addition to text, as it has a 320 x 240 pixel monochrome LCD. However, it is primarily intended for simple operator interfaces rather than complex graphical visualizations.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify that the supply is within the acceptable voltage range and that the connector is properly seated.
Restore correct 24 V DC supply voltage. If voltage is correct and display remains blank, the internal power supply or backlight may have failed, requiring panel repair or replacement.
Panel shows 'No connection to PLC' message at runtime
Verify MPI or PROFIBUS DP cable connections at both the panel and PLC ends. Check that bus termination resistors are correctly placed at both ends of the network segment. Confirm the PLC station address and baud rate match the project settings.
Correct any wiring faults, replace damaged cables, and ensure proper bus termination. Adjust the PLC address and baud rate in the WinCC flexible project if they do not match the physical network configuration, then re-download the project.
Project download fails from PC to panel
Check the PC-to-panel communication cable for continuity and correct pinout. Verify that WinCC flexible is set to the correct transfer mode and that the panel is in transfer mode (accessible via the panel's Start Center menu).
Replace the communication cable if faulty. Place the panel in transfer mode manually via the Start Center. Ensure the WinCC flexible project version is compatible with the installed panel firmware, updating firmware via ProSave if necessary.
Membrane keypad buttons are unresponsive
Inspect the keypad membrane for physical damage, contamination, or deformation. Attempt a panel restart to rule out a software lockup. Check whether the issue is limited to specific keys or affects all keys.
Clean the keypad surface if contaminated. If specific keys are permanently unresponsive due to membrane wear or damage, the keypad membrane assembly requires replacement. If all keys are unresponsive after restart, the panel may require service.
Alarm messages are not displayed on the panel
Verify that alarm tags are correctly configured in the WinCC flexible project and that the corresponding PLC bit addresses are correct. Check that the alarm view object is present and correctly configured on the relevant screen.
Correct tag addresses in the project configuration and re-download the project to the panel. Ensure the PLC program is setting the correct alarm bits and that the alarm class is enabled in the project settings.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page