• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6321-1FC14-0CY6 SIMATIC OP 7
    Awaiting product image

    Siemens 6AV6321-1FC14-0CY6 SIMATIC OP 7

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6321-1FC14-0CY6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6321-1FC14-0CY6 is an Operator Panel (OP 7) belonging to the SIMATIC HMI family, designed for human-machine interface applications in industrial automation environments. This unit provides a compact, text-based operator interface for monitoring and controlling machine processes. It is part of the SIMATIC OP series, which is widely used across Siemens-based automation systems.

    The OP 7 features a 4-line LCD text display capable of showing alphanumeric characters, function keys for direct operator input, and an integrated membrane keypad for reliable operation in demanding environments. It communicates via the MPI (Multi-Point Interface) and PROFIBUS DP protocols, enabling seamless integration with SIMATIC S7-300 and S7-400 PLCs. The unit operates on a 24 V DC supply and is built to withstand industrial conditions, with a front panel protection rating of IP65.

    The SIMATIC OP 7 is commonly deployed in machine tool control, conveyor systems, packaging machinery, and general factory automation where a cost-effective, text-based operator interface is sufficient. Its compact form factor and robust membrane keypad make it suitable for panel mounting in control cabinets and machine enclosures. The compatibility with SIMATIC S7 controllers and the ProTool configuration software makes it a practical choice for straightforward process visualization and operator interaction tasks.

    Technical Specifications

    Display Type LCD text display
    Display Lines 4 lines
    Characters per Line 20 characters
    Input/Operating Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP
    Protection Rating (Front) IP65
    Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Series/Product Family SIMATIC OP 7
    Configuration Software ProTool
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    No connection to PLC – the OP 7 cannot establish communication with the configured controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the OP 7 configuration.
    Event ID: 10001
    Communication timeout – the connection to the PLC was interrupted during operation.
    Inspect cable integrity and connector seating. Check for electromagnetic interference sources near the communication cable.
    Event ID: 20000
    Configuration error – the project loaded on the OP 7 is incompatible or corrupt.
    Re-transfer the project from ProTool to the OP 7. Verify the project was compiled without errors before transfer.
    Event ID: 40000
    Operating system error – internal firmware or OS fault detected.
    Perform a complete power cycle. If the error persists, reload the operating system firmware via the transfer mode.
    Event ID: 50000
    Memory error – fault detected in the internal memory during self-test.
    Reset the device to factory defaults and re-transfer the project. If the fault persists, the unit may require hardware repair or replacement.
    Event ID: 60000
    Transfer mode active – the OP 7 is waiting for a project download from the configuration PC.
    Transfer the project using ProTool, or restart the device in normal operating mode if transfer is not intended.

    Frequently Asked Questions

    Which PLCs are compatible with the SIMATIC OP 7?

    The OP 7 is compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S5 series controllers using appropriate adapters and configuration.

    What software is used to configure the OP 7?

    The OP 7 is configured using Siemens ProTool software. Projects are compiled in ProTool and transferred to the panel via the MPI or serial interface.

    What is the supply voltage for the 6AV6321-1FC14-0CY6?

    The unit requires a 24 V DC supply voltage for operation.

    What is the front panel protection rating of the OP 7?

    The front panel of the OP 7 carries an IP65 protection rating, making it suitable for environments where dust and water jets may be present.

    Can the OP 7 display graphics or only text?

    The OP 7 is a text-based operator panel and displays alphanumeric characters only. It does not support graphical or bitmap image display.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the supply is within the specified range and the connector is fully seated.

    Restore correct supply voltage. If voltage is present and the display remains blank, inspect the internal fuse and consider replacing the power supply board or the unit.

    OP 7 cannot connect to the PLC

    Verify the MPI or PROFIBUS DP address configured in the OP 7 project matches the PLC address. Check cable wiring, termination resistors at both ends of the bus, and connector integrity.

    Correct address mismatches in the ProTool project and re-transfer. Replace damaged cables or connectors and ensure bus termination is properly applied at both ends.

    Project transfer from PC to OP 7 fails

    Confirm the OP 7 is in transfer mode. Check the MPI or serial cable connection between the PC and the panel. Verify the ProTool project is compiled without errors.

    Restart the OP 7 in transfer mode by holding the appropriate key combination during boot. Use a known-good transfer cable and retry the download.

    Keypad buttons not responding or responding incorrectly

    Inspect the membrane keypad for physical damage, contamination, or wear. Test each key systematically using the OP 7 built-in key test function if available.

    Clean the keypad surface with a dry cloth. If keys are damaged or non-functional, the membrane keypad assembly should be replaced by a qualified technician.

    OP 7 repeatedly resets or reboots during operation

    Monitor the 24 V DC supply for voltage dips or instability under load. Check for loose power connector contacts. Review the event log for specific error codes.

    Stabilize the power supply by using a dedicated 24 V DC source with adequate current capacity. Secure all connector contacts and address any logged fault codes accordingly.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart