• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6321-1EC14-0MY0 SIMATIC OP 321
    Awaiting product image

    Siemens 6AV6321-1EC14-0MY0 SIMATIC OP 321

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6321-1EC14-0MY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6321-1EC14-0MY0 is an operator panel belonging to the SIMATIC OP 321 series, part of Siemens' SIMATIC HMI product line. It is a compact, key-operated operator panel designed for machine-level human-machine interface applications, providing process visualization and operator control functions. This unit is manufactured by Siemens and is intended for integration into industrial control cabinets and machine panels.

    The OP 321 panel features a character-based display for process value indication and status monitoring, along with dedicated function keys and system keys for operator input. It supports serial communication interfaces for connection to SIMATIC S7 PLCs and other compatible controllers. The panel is built to industrial standards, offering a robust housing suitable for front-panel mounting with a defined IP protection rating on the front face, and operates on a 24 V DC supply voltage.

    The SIMATIC OP 321 is typically deployed in manufacturing automation, machine tool control, and process plant environments where a cost-effective, reliable operator interface is required. It is well-suited for applications where alphanumeric display of process data and direct key-based operator input are sufficient, such as packaging machinery, conveyor systems, and general-purpose industrial machinery.

    Technical Specifications

    Input Voltage 24 V DC
    Communication Interface RS-422/RS-485 (MPI/PROFIBUS DP)
    Display Type Character-based LCD
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Series/Product Family SIMATIC OP 321
    Certifications CE, UL
    Relative Humidity 10 % to 90 % (non-condensing)

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the OP panel and the connected PLC or controller. The panel cannot establish or maintain a connection.
    Check the communication cable and connector integrity. Verify the MPI/PROFIBUS address settings on both the panel and the PLC. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Timeout on the communication link. The PLC did not respond within the expected time window.
    Check network cabling and termination resistors. Verify baud rate settings match on both devices. Reduce network load if multiple devices are connected.
    Event ID: 20000
    Configuration or project data error. The loaded project is incompatible with the panel firmware version.
    Re-download the project using a compatible version of SIMATIC ProTool or WinCC flexible. Verify firmware version compatibility before transfer.
    Event ID: 40000
    Internal device error or hardware fault detected within the operator panel.
    Cycle power to the panel. If the fault persists, perform a factory reset. If the error recurs, the panel hardware may require repair or replacement.
    Event ID: 50000
    Power supply undervoltage detected. The 24 V DC supply has dropped below the acceptable operating threshold.
    Measure the supply voltage at the panel power connector. Ensure the supply is within the specified 24 V DC range. Check wiring and power supply unit output.
    System Error: Flash
    Error accessing or writing to the internal flash memory. Project data may be corrupted.
    Re-transfer the project configuration to the panel. If the error persists, the internal flash memory may be faulty and the panel should be sent for repair.
    Watchdog Error
    The panel's internal watchdog timer has triggered, indicating a software or hardware hang condition.
    Power cycle the panel. If the watchdog error recurs repeatedly, update the panel firmware and re-download the project. If unresolved, the panel requires hardware inspection.

    Frequently Asked Questions

    What PLC systems is the SIMATIC OP 321 compatible with?

    The OP 321 is primarily designed for use with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces. Compatibility depends on the specific firmware and project configuration used.

    What software is used to configure and program the OP 321?

    The OP 321 is configured using Siemens SIMATIC ProTool or WinCC flexible engineering software. The project is then transferred to the panel via a serial PC/PPI or MPI cable.

    What is the supply voltage for the 6AV6321-1EC14-0MY0?

    The panel operates on a 24 V DC supply voltage. Ensure the power source is within the specified tolerance range to avoid undervoltage faults.

    What is the IP protection rating of the OP 321?

    The front face of the OP 321 is rated IP65, making it suitable for panel-mount installations where dust and water jet protection is required. The rear of the unit is rated IP20.

    Can the OP 321 panel be used as a replacement for older SIMATIC OP panels?

    The OP 321 is designed as a compact operator panel within the SIMATIC HMI family and may serve as a functional replacement for earlier OP series panels, provided the project is reconfigured and re-downloaded using compatible engineering software.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the panel power connector using a multimeter. Inspect the power connector for loose or damaged wiring. Verify the internal fuse if accessible.

    Restore the supply voltage to within the specified 24 V DC range. Re-seat or replace the power connector. If the supply is correct and the display remains blank, the panel backlight or internal power circuitry may require repair.

    Panel displays a communication error and cannot connect to the PLC

    Verify the MPI or PROFIBUS DP cable is correctly connected and undamaged. Check that the bus address configured on the panel matches the project settings and that the PLC is powered and in RUN mode. Inspect termination resistors at both ends of the bus.

    Replace or reseat the communication cable. Correct any address mismatches in the panel configuration. Ensure proper bus termination is applied. Re-download the project if configuration changes are made.

    Panel freezes or becomes unresponsive during operation

    Determine if the freeze is reproducible under specific conditions, such as a particular screen or operator action. Check for undervoltage on the 24 V DC supply. Review the project for any configuration errors that may cause a software hang.

    Power cycle the panel to restore operation. Update the panel firmware to the latest compatible version and re-download the project. If the issue persists, inspect the hardware for faults and consider panel repair or replacement.

    Project transfer from PC to panel fails

    Check the PC-to-panel communication cable type and connection. Verify that the correct COM port and transfer settings are selected in the engineering software. Confirm that the panel is in transfer mode.

    Use a known-good MPI or PC/PPI cable. Set the panel to transfer mode via the panel menu before initiating the download. Ensure the engineering software version is compatible with the panel firmware version.

    Function keys do not respond or produce incorrect actions

    Check the project configuration to verify that the function keys are correctly assigned in the engineering software. Inspect the keypad membrane for physical damage or contamination.

    Re-download the project with corrected key assignments. If the keypad membrane is physically damaged or worn, the panel should be sent for keypad replacement or repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart