• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6321-1DC14-0MY0 SIMATIC OP 321
    Awaiting product image

    Siemens 6AV6321-1DC14-0MY0 SIMATIC OP 321

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6321-1DC14-0MY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6321-1DC14-0MY0 is an operator panel (OP) belonging to the SIMATIC HMI family, designed for machine-level human-machine interface applications. This unit provides a compact, key-operated interface for process visualization and operator control in industrial environments. It is part of Siemens' established SIMATIC HMI panel portfolio, offering reliable communication with SIMATIC PLCs and other compatible controllers.

    The OP 321 features a monochrome LCD display with a fixed set of function keys and system keys for navigation and control input. It supports MPI and PROFIBUS DP communication interfaces, enabling direct integration with SIMATIC S7-300 and S7-400 PLC families. The panel is configured using Siemens ProTool or WinCC flexible engineering software, and supports text-based visualization with alarm and event logging capabilities. The unit is built for panel mounting with an IP65-rated front face, suitable for industrial cabinet installation.

    This operator panel is commonly used in manufacturing, process automation, and machine tool applications where a cost-effective, robust text-based HMI is required. It is well suited for controlling conveyor systems, packaging machinery, and general-purpose industrial machines where graphical display is not required but reliable operator interaction is essential. Its compatibility with the SIMATIC S7 controller family makes it a practical choice for facilities already operating within the Siemens automation ecosystem.

    Technical Specifications

    Display Type Monochrome LCD
    Communication Interface MPI, PROFIBUS DP
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Mounting Panel mounting
    Configuration Software ProTool, WinCC flexible
    PLC Compatibility SIMATIC S7-300, S7-400
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP panel and the connected PLC. The panel cannot establish or maintain a connection.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the panel configuration. Ensure the PLC is in RUN mode.
    Event ID: 10001
    Configured PLC address not found on the network. The panel cannot locate the target controller.
    Verify the PLC station address in the project configuration matches the physical PLC address setting. Check network cabling and bus termination.
    Event ID: 20000
    Project download error. Transfer of the configuration project to the panel has failed.
    Check the transfer cable connection. Ensure the panel is in transfer mode before initiating download. Verify compatibility between the ProTool/WinCC flexible version and the panel firmware.
    Event ID: 30000
    Panel operating system or firmware error detected during startup.
    Perform a panel reset. If the fault persists, reload the panel firmware using the appropriate Siemens service tool and re-download the project.
    Event ID: 40000
    Alarm buffer overflow. The number of pending alarms has exceeded the panel's storage capacity.
    Acknowledge and clear existing alarms on the panel. Review the alarm configuration in the project to reduce unnecessary alarm generation.
    Event ID: 50000
    Recipe data error. Recipe records cannot be read or written correctly.
    Check the recipe configuration in the project. Verify that the data block addresses in the PLC match those defined in the panel project. Re-download the project if necessary.

    Frequently Asked Questions

    Which PLCs are compatible with the 6AV6321-1DC14-0MY0 operator panel?

    This panel is compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with SIMATIC S5 controllers using appropriate adapters and configuration.

    What software is used to configure this operator panel?

    The panel is configured using Siemens ProTool or WinCC flexible engineering software. The project is then transferred to the panel via the MPI interface or a dedicated PC adapter cable.

    What is the supply voltage for this panel?

    The panel operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI devices and compatible with typical industrial control cabinet power supplies.

    What is the front protection rating of this panel?

    The front face of the panel carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for installation in industrial control panels.

    Can this panel be used as a replacement for older SIMATIC OP panels?

    Yes, the OP 321 is designed as a compatible replacement within the SIMATIC HMI operator panel family. Project migration from older OP panels may require adaptation using WinCC flexible or ProTool migration tools.

    Troubleshooting

    Panel display remains blank after power on

    Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify the supply is within the specified voltage range and that the connector is fully seated.

    Restore the correct 24 V DC supply. If voltage is correct and the display remains blank, the internal power supply or backlight may be faulty and the panel should be sent for repair or replacement.

    Panel shows 'No connection to PLC' message

    Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the PLC address configured in the panel project matches the actual PLC station address.

    Correct any address mismatches in the project configuration and re-download. Replace the communication cable if damaged. Ensure bus termination resistors are correctly placed at both ends of the network segment.

    Project download fails or transfer does not start

    Confirm the panel is set to transfer mode before initiating the download from the PC. Check the PC adapter cable connection and verify the correct COM port or USB adapter is selected in the software.

    Switch the panel to transfer mode via the panel menu. Re-seat the transfer cable and retry the download. If using a USB-to-MPI adapter, ensure the correct driver is installed on the PC.

    Function keys do not respond or produce incorrect actions

    Check the panel project configuration to verify that function key assignments are correctly defined. Test individual keys to determine if the issue is with a single key or all keys.

    Re-download the project with corrected key assignments if a configuration error is found. If a key is physically unresponsive, the keypad membrane may be worn or damaged and requires hardware replacement.

    Panel restarts repeatedly or enters a boot loop

    This may indicate a corrupted project file or a firmware issue. Observe whether the panel reaches the operating screen before restarting, which can help distinguish between a project error and a firmware fault.

    Attempt to re-download the project from the engineering PC. If the panel cannot be reached, perform a factory reset and reload the firmware using the Siemens service utility before re-downloading the project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart