• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6321-1DC03-1MY0 SIMATIC OP 321
    Awaiting product image

    Siemens 6AV6321-1DC03-1MY0 SIMATIC OP 321

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6321-1DC03-1MY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6321-1DC03-1MY0 is an operator panel (OP) belonging to the SIMATIC HMI family, designed for human-machine interface applications in industrial automation environments. This unit provides a compact, key-operated interface for process visualization and machine control, enabling operators to monitor and interact with automated systems. It is part of Siemens' established SIMATIC HMI portfolio, which is widely deployed across manufacturing and process industries.

    The OP 321 panel features a monochrome display with a matrix of function keys and system keys, allowing structured navigation through configured screens and process values. It communicates with SIMATIC S7 PLCs via the MPI (Multi-Point Interface) or PROFIBUS DP protocol, enabling direct integration into existing Siemens automation networks. The unit is configured using Siemens ProTool or WinCC flexible engineering software, and supports alarm management, recipe handling, and trend display functions within its operational scope.

    This operator panel is suited for use in machine building, automotive production lines, food and beverage processing, and general factory automation where a robust, key-based HMI interface is required. Its compact form factor and compatibility with SIMATIC S7-300 and S7-400 controllers make it a practical choice for retrofit and new installation projects. The panel is designed for panel mounting in control cabinet doors and operator stations in industrial environments.

    Technical Specifications

    Display Type Monochrome LCD
    Communication Interface MPI / PROFIBUS DP
    Input/Operating Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 %, non-condensing
    IP Protection Rating (Front) IP65
    Mounting Panel mounting
    Series/Product Family SIMATIC HMI OP
    Engineering Software ProTool / WinCC flexible
    PLC Compatibility SIMATIC S7-300, S7-400
    Certifications CE, UL

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the OP panel and the connected PLC. The connection to the configured controller has been lost or cannot be established.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC is powered and the configured MPI/PROFIBUS address matches the project settings.
    Event ID: 10001
    Timeout on the communication link. The panel did not receive a response from the PLC within the expected time window.
    Check network cabling and bus termination. Reduce bus load or increase the configured communication timeout value in the project settings.
    Event ID: 20000
    Project download error. A fault occurred during transfer of the configuration project to the panel.
    Verify the PC-to-panel connection cable is intact. Ensure the correct COM port and transfer settings are selected in ProTool or WinCC flexible. Retry the download.
    Event ID: 40000
    Internal memory error. The panel has detected a fault in its internal flash or RAM memory.
    Perform a panel reset and re-download the project. If the fault persists, the internal memory may be corrupted and the unit should be sent for repair or replacement.
    Event ID: 50000
    Configuration error. The loaded project is incompatible with the panel firmware version or hardware variant.
    Check the project settings in ProTool or WinCC flexible to ensure the correct panel type and firmware version are selected. Update firmware if necessary and re-download the project.
    Event ID: 60000
    Power supply undervoltage detected. The 24 V DC supply voltage has dropped below the minimum operating threshold.
    Measure the supply voltage at the panel power connector. Ensure the power supply unit is rated for the panel load and that cable voltage drop is within acceptable limits.
    System Error: Tag Limit Exceeded
    The number of configured tags in the project exceeds the maximum supported by this panel variant.
    Review the project configuration and reduce the number of configured tags to within the supported limit for the OP 321 panel.

    Frequently Asked Questions

    Which PLCs are compatible with the Siemens 6AV6321-1DC03-1MY0?

    This panel is compatible with Siemens SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces.

    What engineering software is used to configure this operator panel?

    The panel is configured using Siemens ProTool or WinCC flexible software. The project is then transferred to the panel via a PC adapter cable.

    What is the supply voltage required for this panel?

    The panel requires a 24 V DC power supply for operation.

    What is the IP protection rating of the 6AV6321-1DC03-1MY0?

    The front face of the panel is rated IP65, making it suitable for panel door mounting in environments where dust and water spray may be present.

    Can this panel be used as a replacement for older SIMATIC OP panels?

    Yes, the OP 321 is designed to be compatible within the SIMATIC HMI OP family and can serve as a replacement in existing installations, provided the project is reconfigured for the correct panel type in the engineering software.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify polarity is correct and voltage is within the specified range.

    Correct any wiring errors or replace the external power supply if the voltage is out of range. If supply voltage is correct and the display remains blank, the internal power supply or display unit may be faulty and the panel should be inspected for repair.

    Panel displays a communication error and cannot connect to the PLC

    Verify the MPI or PROFIBUS DP cable is securely connected at both the panel and PLC ends. Check that bus termination resistors are correctly installed at both ends of the network segment.

    Replace or reseat the communication cable. Confirm that the MPI or PROFIBUS address configured in the panel project matches the address set on the PLC. Ensure no address conflicts exist on the bus.

    Project download fails or transfer is interrupted

    Check the PC-to-panel transfer cable and the COM port settings in ProTool or WinCC flexible. Ensure the panel is set to transfer mode before initiating the download.

    Replace the transfer cable if damaged. Select the correct COM port and baud rate in the engineering software. Place the panel in transfer mode via the panel's start menu and retry the download.

    Panel keys are unresponsive or register incorrect inputs

    Inspect the keypad membrane for physical damage, contamination, or wear. Check whether the issue is consistent across all keys or limited to specific ones.

    Clean the keypad surface with a dry cloth. If specific keys are permanently unresponsive, the keypad membrane assembly may need to be replaced. Contact a qualified repair technician for membrane replacement.

    Alarm messages are not displayed or are missing on the panel

    Verify that alarm tags are correctly configured in the project and that the communication link to the PLC is active. Check that the alarm view object is present on the relevant screen in the project.

    Re-check the alarm configuration in ProTool or WinCC flexible, ensuring alarm bits are mapped to the correct PLC data addresses. Re-download the corrected project to the panel and confirm PLC communication is established.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart