• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6321-1BA23-1MY0 OP 321
    Awaiting product image

    Siemens 6AV6321-1BA23-1MY0 OP 321

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6321-1BA23-1MY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6321-1BA23-1MY0 is an operator panel (OP 321) belonging to the SIMATIC HMI family, designed for human-machine interface applications in industrial automation environments. This unit provides a compact, text-based display solution for process visualization and machine control, and is part of Siemens' established line of operator panels intended for integration with SIMATIC PLCs. The 6AV6321-1BA23-1MY0 variant offers a defined set of display and communication capabilities suited to straightforward control tasks.

    The OP 321 features a multi-line LCD text display capable of showing alphanumeric characters and status information, with a membrane keypad for operator input. It supports serial communication interfaces, typically MPI and/or PROFIBUS DP, enabling direct connection to SIMATIC S7-300 and S7-400 controllers. The panel includes configurable function keys, an integrated real-time clock, and is configured using Siemens ProTool or WinCC flexible engineering software. The unit operates on a 24 V DC supply and is built to meet industrial environmental requirements.

    The OP 321 is commonly deployed in machine tool control, conveyor systems, packaging machinery, and process automation installations where a cost-effective, text-based operator interface is sufficient. Its compact form factor and compatibility with the SIMATIC S7 controller family make it well-suited for retrofit and new installation projects in manufacturing and process industries. The panel is designed for panel mounting and is appropriate for applications requiring reliable status display and basic operator input without the need for graphical visualization.

    Technical Specifications

    Series/Product Family SIMATIC HMI OP 321
    Display Type LCD text display
    Display Lines 4 lines
    Characters per Line 20 characters
    Input/Operating Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    IP Rating (Front) IP65
    Mounting Panel mounting
    Certifications CE, UL
    Configuration Software ProTool, WinCC flexible

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the configuration in the project. Restart both the panel and the PLC.
    Event ID: 10001
    PLC not responding. The operator panel has lost communication with the configured SIMATIC controller.
    Verify the PLC is powered and in RUN mode. Check the communication cable and bus address configuration. Confirm the MPI/PROFIBUS network parameters in the project settings.
    Event ID: 20000
    Configuration error detected. The project loaded on the panel is incompatible or corrupt.
    Re-download the project from the engineering PC using ProTool or WinCC flexible. Verify the correct device type is selected in the project settings before transferring.
    Event ID: 40000
    Internal device error. A hardware fault has been detected within the operator panel.
    Cycle power to the panel. If the error persists, perform a factory reset. If the fault remains, the unit requires repair or replacement.
    Event ID: 50000
    Transfer mode active. The panel is waiting for a project download from the engineering station.
    Initiate a project transfer from the engineering PC using ProTool or WinCC flexible, or press the appropriate key combination to exit transfer mode and return to normal operation.
    Event ID: 60000
    Memory error. Insufficient memory available to load or run the configured project.
    Reduce the project size by removing unused screens, variables, or messages. Re-download the optimized project to the panel.
    Event ID: 70000
    Keypad fault detected. One or more keys on the membrane keypad are not responding correctly.
    Inspect the keypad membrane for physical damage or contamination. If a key is stuck or damaged, the keypad assembly may require replacement.

    Frequently Asked Questions

    Which PLCs are compatible with the OP 321?

    The OP 321 is designed for use with Siemens SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces. It can also be used with S5 controllers via appropriate adapters in some configurations.

    What software is used to configure the OP 321?

    The OP 321 is configured using Siemens ProTool or WinCC flexible engineering software. Projects are transferred to the panel via the MPI interface or a serial PC adapter cable.

    What is the supply voltage for the 6AV6321-1BA23-1MY0?

    The panel operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI operator panels in this series.

    What is the front panel protection rating of the OP 321?

    The OP 321 provides IP65 protection at the front panel when correctly installed in a control cabinet cutout, making it suitable for environments with dust and water spray.

    Can the OP 321 display graphical content?

    No, the OP 321 is a text-based operator panel and displays alphanumeric characters only. For graphical visualization, a SIMATIC HMI panel such as the TP or MP series should be used instead.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel's power connector. Check for blown fuses in the control cabinet supply circuit. Verify the power connector is fully seated.

    Restore the 24 V DC supply to within specification. Replace any blown fuses in the supply circuit. If the supply is correct and the display remains blank, the internal power supply or display unit may be faulty and require repair or replacement.

    Panel shows communication error and cannot connect to PLC

    Check the MPI or PROFIBUS DP cable for continuity and correct termination at both ends of the bus. Verify the bus address configured on the panel matches the project settings and does not conflict with other devices on the network.

    Replace or reseat the communication cable. Correct the bus address settings on the panel and in the PLC project. Ensure bus termination resistors are enabled only at the physical ends of the network.

    Project transfer from engineering PC fails

    Verify the PC adapter cable is correctly connected to the panel's MPI port and the PC. Check that the transfer mode is active on the panel and that the correct COM port and transfer rate are selected in ProTool or WinCC flexible.

    Set the panel to transfer mode by pressing the appropriate key combination during startup. Confirm the baud rate and interface settings in the engineering software match the panel configuration. Try a different PC adapter cable if the issue persists.

    Function keys do not respond to operator input

    Inspect the membrane keypad surface for physical damage, contamination, or deformation. Test each key systematically in the panel's diagnostic or test mode if available.

    Clean the keypad surface with a dry cloth. If keys are physically damaged or the membrane is torn, replace the keypad membrane assembly. If the issue is software-related, re-download the project to ensure correct key assignments.

    Panel repeatedly restarts or enters an error loop after loading project

    Check whether the project was created for the correct panel type and firmware version. A mismatch between the project configuration and the panel hardware can cause boot failures.

    Open the project in ProTool or WinCC flexible and verify the target device is set to OP 321. Re-download the corrected project. If the panel continues to restart, perform a factory reset and re-transfer the project from scratch.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart