• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6321-1BA23-1CY0 SIMATIC OP3
    Awaiting product image

    Siemens 6AV6321-1BA23-1CY0 SIMATIC OP3

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6321-1BA23-1CY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6321-1BA23-1CY0 is an operator panel (OP3) belonging to the SIMATIC HMI family, designed for compact machine-level operator control and monitoring tasks. This unit is a text-based operator panel capable of displaying alphanumeric information across two lines, making it suitable for straightforward process visualization and parameter input. It is manufactured by Siemens as part of the SIMATIC HMI portfolio and is intended for integration into control cabinets and machine panels.

    The OP3 features a two-line LCD display capable of showing 20 characters per line, providing clear readout of process values, alarms, and status messages. It communicates via the MPI (Multi-Point Interface) and PROFIBUS DP protocols, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs. The panel includes a membrane keypad with function keys for operator input, and configuration is performed using the ProTool software package. The unit operates on a 24 V DC supply and is built to withstand typical industrial environments.

    The SIMATIC OP3 is commonly deployed in manufacturing, packaging, and process automation applications where a cost-effective, compact HMI solution is required. It is well-suited for small to medium-sized machines where basic text-based operator interaction is sufficient, such as conveyor systems, pumping stations, and simple assembly lines. Its compact form factor and compatibility with the SIMATIC S7 PLC family make it a practical choice for retrofit and new installation projects in industrial settings.

    Technical Specifications

    Display Type LCD, text-based
    Display Lines 2 lines x 20 characters
    Input/Operating Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP
    Keypad Membrane keypad with function keys
    Configuration Software ProTool
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the OP3 and the connected PLC. The panel cannot establish or maintain a connection.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the configuration in ProTool. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Configured PLC address not found on the network. The OP3 cannot locate the target controller.
    Verify the PLC station address configured in ProTool matches the physical PLC address setting. Check network wiring and bus termination.
    Event ID: 20000
    Project download error. Transfer of the configuration project from the engineering PC to the OP3 has failed.
    Check the data transfer cable connection between the PC and OP3. Ensure ProTool is using the correct COM port and transfer settings. Retry the download.
    Event ID: 30000
    Tag read error. The OP3 is unable to read a configured process tag from the PLC.
    Verify the tag address configured in ProTool corresponds to a valid address in the PLC program. Check PLC data block or memory area availability.
    Event ID: 40000
    Alarm buffer overflow. The number of pending alarms has exceeded the panel's alarm buffer capacity.
    Acknowledge and clear existing alarms on the panel. Review the alarm configuration in ProTool to reduce unnecessary alarm triggers.
    System Error
    Internal device fault detected. The OP3 has encountered an unrecoverable internal error.
    Cycle power to the panel. If the error persists, perform a factory reset or reload the project configuration. If the fault continues, the unit may require repair or replacement.
    Transfer Mode Active
    The panel is in transfer mode awaiting a project download and is not displaying the runtime application.
    Initiate a project transfer from the ProTool engineering station, or press the appropriate key combination to exit transfer mode and return to normal operation.

    Frequently Asked Questions

    Which PLCs are compatible with the SIMATIC OP3 (6AV6321-1BA23-1CY0)?

    The OP3 is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP communication interfaces.

    What software is used to configure the OP3 panel?

    The OP3 is configured using Siemens ProTool software. WinCC flexible is not supported for this panel generation.

    What is the supply voltage for the 6AV6321-1BA23-1CY0?

    The panel operates on a 24 V DC supply voltage.

    What is the front panel protection rating of the OP3?

    The front panel of the OP3 carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.

    Can the OP3 display graphics or images?

    No, the OP3 is a text-based operator panel and can only display alphanumeric characters across its two-line LCD display. It does not support graphical content.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel's power connector. Verify polarity is correct and the supply is within the specified voltage range.

    Ensure the power supply is providing stable 24 V DC. Check wiring connections and terminal tightness. If the supply is correct and the display remains blank, the internal power circuitry or LCD may be faulty and the unit should be sent for repair.

    OP3 shows communication error and cannot connect to PLC

    Verify the MPI or PROFIBUS DP cable is properly connected and terminated at both ends. Check that the bus termination resistors are enabled only at the physical ends of the network segment.

    Correct any wiring faults and ensure proper bus termination. Confirm the PLC address in the OP3 project matches the actual PLC station address. Restart both the PLC and the OP3 after making corrections.

    Panel is stuck in transfer mode and will not run the project

    The OP3 enters transfer mode automatically if no valid project is loaded or if it was interrupted during a previous download.

    Connect the engineering PC running ProTool and perform a complete project download. Once the transfer completes successfully, the panel will restart and enter runtime mode automatically.

    Function keys do not respond to operator input

    Inspect the membrane keypad for physical damage, contamination, or deformation. Check whether the issue affects all keys or only specific ones.

    Clean the keypad surface with a dry cloth. If individual keys are unresponsive due to membrane damage, the keypad membrane assembly will need to be replaced. Contact a qualified repair technician for membrane replacement.

    Alarm messages are not displaying correctly or are truncated

    Review the alarm text configuration in ProTool. The OP3 display is limited to 20 characters per line, so alarm messages exceeding this length will be truncated.

    Edit the alarm text strings in ProTool to fit within the 20-character per line limit. Re-download the updated project to the panel and verify alarm display in runtime.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart