• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6146-4MM40-2KY2 SIMATIC MP 377
    Awaiting product image

    Siemens 6AV6146-4MM40-2KY2 SIMATIC MP 377

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6146-4MM40-2KY2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6146-4MM40-2KY2 is a Multi Panel belonging to the SIMATIC MP 377 series, part of Siemens' SIMATIC HMI product line. This panel operates as a high-performance operator interface device designed for demanding industrial visualization and control tasks. It features a 15-inch widescreen TFT display and is built to integrate seamlessly within Siemens automation environments.

    The MP 377 15" Touch features a 15-inch TFT display with a resolution of 1024 x 768 pixels and 64,000 colors, combined with a resistive touchscreen interface for operator input. It is equipped with a 1 GHz processor and 128 MB RAM along with 128 MB flash memory, enabling smooth execution of complex HMI projects. Communication interfaces include PROFIBUS DP, PROFINET/Ethernet (RJ45), USB ports, and a CF card slot for data storage and project transfer. The panel operates on a 24 V DC supply and supports MPI/PROFIBUS DP connectivity for direct integration with Siemens S7 PLCs.

    The SIMATIC MP 377 15" Touch is widely used in manufacturing, process automation, machine building, and plant engineering applications where a large, high-resolution display is required for operator interaction. Its robust construction and wide operating temperature range make it suitable for installation in industrial control cabinets and harsh production environments. Industries such as automotive, food and beverage, chemical processing, and packaging machinery commonly deploy this panel for supervisory control and data visualization tasks.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Colors 64,000 colors
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Processor 1 GHz
    RAM 128 MB
    Flash Memory 128 MB
    Communication Interface PROFIBUS DP, PROFINET/Ethernet (RJ45), MPI, USB
    Memory Card Slot CompactFlash (CF) card
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    IP/Protection Rating IP65 (front panel)
    Certifications CE, UL, cULus
    Mounting Panel mounting

    Common Error Codes & System Events

    Event ID: 1000
    System startup completed. The HMI device has successfully booted and the runtime environment is initialized.
    No action required. This is an informational event confirming normal startup.
    Event ID: 10000
    Connection to PLC lost. The HMI panel cannot establish or has lost communication with the configured PLC.
    Check PROFIBUS/PROFINET cabling and connector integrity. Verify PLC is powered and running. Confirm station address and network settings in the HMI project configuration.
    Event ID: 10001
    Connection to PLC established. Communication between the HMI panel and the PLC has been successfully restored.
    No action required. This is an informational event confirming restored communication.
    Event ID: 20000
    Tag read error. The HMI runtime was unable to read a configured tag from the PLC.
    Verify the tag address exists in the PLC program. Check data block numbers and variable addresses in WinCC flexible or TIA Portal project. Ensure PLC program is not in STOP mode.
    Event ID: 40000
    Project transfer active. A project download to the HMI device is in progress.
    No action required during intentional transfers. If unexpected, check for unauthorized access to the panel network connection.
    Event ID: 70010
    Internal flash memory error. A read or write operation to the internal flash memory has failed.
    Restart the HMI device. If the error persists, back up the project and perform a factory reset. Replace the unit if the flash memory is physically damaged.
    Event ID: 110000
    Backup/restore operation failed. An error occurred during project backup or restore via CF card or USB.
    Check the CF card or USB storage device for errors and sufficient free space. Reformat the storage medium if necessary and retry the operation.

    Frequently Asked Questions

    What PLC systems is the SIMATIC MP 377 15" Touch compatible with?

    The MP 377 is compatible with Siemens S7-300, S7-400, S7-1200, and S7-1500 PLCs via MPI, PROFIBUS DP, or PROFINET/Ethernet. It can also communicate with third-party controllers using standard protocols such as Modbus TCP or OPC.

    What software is used to configure and program the 6AV6146-4MM40-2KY2?

    This panel is configured using Siemens WinCC flexible 2008 or SIMATIC WinCC (TIA Portal). Projects created in WinCC flexible can be transferred to the panel via Ethernet, USB, or CF card.

    What is the supply voltage for the MP 377 15" Touch?

    The panel requires a 24 V DC power supply. It is recommended to use a regulated SELV power supply meeting IEC 60364-4-41 requirements.

    Does the MP 377 support remote access or VNC functionality?

    Yes, the SIMATIC MP 377 supports Sm@rtAccess and Sm@rtService functions, allowing remote monitoring and control via VNC-compatible clients over an Ethernet network.

    What is the IP protection rating of the front panel?

    The front panel of the MP 377 15" Touch carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for installation in industrial enclosures.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check that the voltage is within the acceptable range. Inspect the internal fuse if accessible.

    Ensure the power supply is providing stable 24 V DC. Replace the power supply if voltage is out of range. If the backlight has failed, the panel may require backlight or display assembly replacement.

    Touchscreen does not respond or responds inaccurately

    Attempt to recalibrate the touchscreen via the Control Panel in the Start menu of the panel OS. Check for physical damage or contamination on the touch surface.

    Perform a touchscreen recalibration through the SIMATIC HMI Control Panel. Clean the screen surface with a soft, dry cloth. If calibration fails repeatedly, the touchscreen overlay may need replacement.

    HMI cannot communicate with the PLC over PROFIBUS

    Check the PROFIBUS cable connections and termination resistors at both ends of the network segment. Verify the PROFIBUS station address configured on the HMI matches the project settings.

    Reseat the PROFIBUS connector and ensure correct bus termination is applied. Confirm the station address in the HMI Control Panel under PROFIBUS settings matches the WinCC flexible project configuration. Replace the PROFIBUS cable if continuity testing reveals a fault.

    Panel freezes or restarts unexpectedly during operation

    Check the supply voltage for ripple or voltage drops under load. Review the system event log in WinCC flexible Runtime for recurring error event IDs. Check for overheating by measuring ambient temperature around the panel.

    Stabilize the 24 V DC power supply and ensure adequate ventilation around the panel. Update the HMI firmware to the latest compatible version. If the issue persists, back up the project and perform a factory reset, then reload the project.

    CF card is not recognized by the panel

    Inspect the CF card slot for debris or bent contacts. Test the CF card in a separate card reader to verify it is not corrupted or faulty.

    Clean the CF card slot contacts carefully. Reformat the CF card to FAT32 using a PC and retry. Replace the CF card if it is found to be defective. Ensure the card capacity and type are compatible with the MP 377 specifications.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart