Siemens 6AV6146-3MM41-1KY2 SIMATIC MP 377
€ 1.995,00
The Siemens 6AV6146-3MM41-1KY2 is a Multi Panel (MP 377) belonging to the SIMATIC HMI family, designed for high-performance human-machine interface applications in industrial automation environments. This panel features a 15-inch widescreen TFT display and is part of the MP 377 series, which represents Siemens' advanced multi-panel platform offering both visualization and control capabilities. It is a Windows CE-based operator panel intended for demanding process visualization tasks.
The MP 377 15" Touch (6AV6146-3MM41-1KY2) is equipped with a resistive touchscreen and delivers a display resolution of 1024 x 768 pixels with 64,000 colors. It features multiple communication interfaces including PROFIBUS DP, PROFINET/Ethernet (RJ45), USB ports, and a CF card slot for extended memory and data storage. The panel runs on Windows CE 6.0 and is compatible with WinCC flexible and TIA Portal (WinCC RT Advanced) engineering software, supporting a wide range of Siemens and third-party PLC connections.
The SIMATIC MP 377 is widely deployed in industries such as automotive manufacturing, food and beverage processing, chemical plants, and water treatment facilities. Its large display area and multi-touch capability make it suitable for complex process visualization, recipe management, alarm logging, and trend display on machines and production lines where operators require detailed real-time data. The robust industrial housing and wide operating temperature range ensure reliable operation in harsh factory floor environments.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Colors | 64,000 colors |
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Operating System | Windows CE 6.0 |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 60 W |
| Communication Interface | PROFIBUS DP, PROFINET (Ethernet RJ45), USB 2.0 (x2), CF card slot |
| Engineering Software | WinCC flexible 2008 / WinCC RT Advanced (TIA Portal) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI MP 377 |
Common Error Codes & System Events
- Event ID: 040000
- Configuration error detected during startup; the project loaded on the panel contains configuration faults.
Check the WinCC flexible or WinCC RT Advanced project for configuration errors, recompile and re-download the project to the panel. - Event ID: 070000
- Communication error between the HMI panel and the connected PLC or controller.
Verify PROFIBUS or PROFINET connection cables and connectors, check PLC address settings, and confirm the communication driver configuration in the project. - Event ID: 080000
- Tag read/write error; the HMI panel cannot access a configured PLC tag.
Check that the PLC is in RUN mode, verify tag addresses in the project configuration, and ensure the communication link is active. - Event ID: 110000
- Alarm buffer overflow; the number of pending alarms exceeds the buffer capacity.
Acknowledge and clear existing alarms, review alarm configuration to reduce unnecessary alarm triggers, and consider increasing the alarm buffer size in the project settings. - Event ID: 130000
- Data record transfer error; a recipe or data record could not be read or written correctly.
Check the recipe configuration, verify available storage space on the CF card or internal memory, and re-attempt the data record transfer. - Event ID: 160000
- Printer communication error; the panel cannot communicate with the configured printer.
Check printer connection and driver settings, verify printer configuration in the WinCC project, and ensure the printer is powered on and online. - Event ID: 050000
- Illegal system activity detected; an internal system fault has occurred on the panel.
Perform a controlled restart of the panel. If the fault persists, reload the project and consider restoring the panel to factory defaults via the Control Panel.
Frequently Asked Questions
Which engineering software is compatible with the 6AV6146-3MM41-1KY2?
This panel is compatible with WinCC flexible 2008 SP3 or later, as well as WinCC RT Advanced within the TIA Portal engineering framework. Projects must be compiled and downloaded via these tools.
What communication interfaces are available on the MP 377 15" Touch?
The panel provides a PROFIBUS DP interface, one or two PROFINET/Ethernet RJ45 ports, USB 2.0 host ports, and a CompactFlash (CF) card slot for data storage and project transfer.
What is the supply voltage for the SIMATIC MP 377?
The MP 377 operates on 24 V DC supply voltage. Ensure a stable, regulated 24 V DC power supply is used to prevent operational issues.
Is the MP 377 compatible with third-party PLCs?
Yes, the MP 377 supports communication drivers for a range of third-party PLCs including Allen-Bradley, Mitsubishi, Omron, and Modbus-compatible controllers, configurable through WinCC flexible or TIA Portal.
How is the MP 377 panel mounted?
The panel is designed for portrait or landscape panel mounting into a control cabinet cutout. The front face provides IP65 protection when correctly installed with the supplied mounting clamps.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel's power connector. Check that the supply is within the specified tolerance and that the power connector is firmly seated.
Correct any supply voltage issues. If voltage is correct, check the internal backlight fuse. If the backlight has failed, the panel may require backlight or display assembly replacement.
Touchscreen does not respond or responds inaccurately
Check for physical damage or contamination on the touchscreen surface. Attempt to recalibrate the touch input via the Windows CE Control Panel touch calibration utility.
Clean the touchscreen surface with a soft, dry cloth. Perform a touch recalibration. If the problem persists after recalibration, the resistive touch overlay may need to be replaced.
Panel fails to communicate with the PLC via PROFIBUS or PROFINET
Verify the physical cable connections and check for correct PROFIBUS address or IP address configuration on both the panel and the PLC. Use diagnostic tools in WinCC to check the connection status.
Correct any address mismatches, replace damaged cables, and ensure the correct communication driver is selected in the project. Restart both the panel and PLC after making changes.
Project download from engineering PC fails or times out
Check the Ethernet or USB connection between the engineering PC and the panel. Verify that the panel is in transfer mode and that the correct transfer channel is selected in WinCC flexible or TIA Portal.
Switch the panel to transfer mode via the Start Center, ensure firewall settings on the PC are not blocking the connection, and retry the download. Use a direct Ethernet connection rather than a network switch if possible.
Panel restarts unexpectedly or freezes during operation
Check the 24 V DC supply for voltage dips or instability using a multimeter or oscilloscope. Review the alarm and event logs on the panel for any recorded system events prior to the restart.
Stabilize the power supply, ensure adequate ventilation around the panel to prevent overheating, and verify that the project does not contain script errors or excessive polling cycles that could overload the processor.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page