• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6146-3MM41-0KY2 SIMATIC MP 377
    Awaiting product image

    Siemens 6AV6146-3MM41-0KY2 SIMATIC MP 377

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6146-3MM41-0KY2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6146-3MM41-0KY2 is a Multi Panel (MP 377) belonging to the SIMATIC HMI family, designed for high-performance human-machine interface applications in industrial automation environments. This panel features a 15-inch widescreen TFT display and is part of the MP 377 series, which represents Siemens' advanced multi-panel lineup offering both visualization and control capabilities. The unit is engineered for demanding industrial settings where reliable operator interaction and process visualization are essential.

    The MP 377 15" touch panel features a 1024 x 768 pixel XGA resolution TFT display with 64,000 colors and resistive touch technology for precise operator input. It is equipped with multiple communication interfaces including PROFIBUS DP, PROFINET/Ethernet (RJ45), USB ports, and a CompactFlash card slot for extended memory and data logging. The panel runs on WinCC flexible runtime software and supports MPI, PROFIBUS, and Ethernet-based communication protocols, enabling integration with SIMATIC S7 PLCs and third-party controllers. Operating on 24 V DC supply voltage, the unit provides robust performance with a fanless design suited to continuous industrial operation.

    The SIMATIC MP 377 is widely deployed in manufacturing, process automation, water treatment, energy management, and machine tool industries where a large-format, feature-rich HMI panel is required. Its support for PROFIBUS DP and PROFINET makes it directly compatible with SIMATIC S7-300 and S7-400 PLC families, as well as S7-1500 via appropriate drivers. The panel's versatility and connectivity make it suitable for complex SCADA-level visualization tasks on standalone machines and distributed plant-wide control systems alike.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 px (XGA)
    Display Colors 64,000 colors
    Display Type TFT LCD
    Touch Technology Resistive
    Input Voltage 24 V DC
    Power Consumption Approx. 40 W
    Communication Interface PROFIBUS DP, PROFINET/Ethernet (RJ45), MPI, USB (2x), CompactFlash slot
    Operating System Windows CE 6.0
    Runtime Software WinCC flexible 2008
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC MP 377

    Common Error Codes & System Events

    Event ID: 1000000
    System startup completed. The HMI device has booted successfully and the runtime environment is active.
    No action required. This is an informational system event confirming normal startup.
    Event ID: 1000002
    Connection to PLC lost. The HMI panel cannot establish or maintain communication with the configured controller.
    Check PROFIBUS/PROFINET cabling and termination resistors. Verify PLC is powered and online. Confirm communication parameters (address, baud rate) match in WinCC flexible project.
    Event ID: 1000003
    Connection to PLC established. Communication with the configured controller has been successfully restored.
    No action required. This is an informational event confirming restored communication.
    Event ID: 1000022
    Tag read error. The HMI runtime was unable to read a configured tag from the PLC.
    Verify the tag address exists in the PLC program and the data block is not write-protected. Check for address mismatches between the HMI project and the PLC data structure.
    Event ID: 1000023
    Tag write error. The HMI runtime was unable to write a value to a configured PLC tag.
    Confirm the target PLC address is writable and not protected. Check communication status and verify the tag configuration in WinCC flexible.
    Event ID: 1000070
    Project transfer active. A project download from the engineering PC to the HMI panel is in progress.
    No action required during intentional transfers. If unexpected, check for unauthorized access to the panel's transfer interface.
    Event ID: 1000080
    Backup/restore operation in progress or failed. The panel encountered an issue during a data backup or restore procedure.
    Ensure the CompactFlash card is properly seated and has sufficient free space. Retry the backup/restore operation. Replace the CompactFlash card if errors persist.

    Frequently Asked Questions

    Which PLC families are compatible with the SIMATIC MP 377?

    The MP 377 is natively compatible with SIMATIC S7-300, S7-400, and S7-1200/1500 PLCs via PROFIBUS DP, MPI, or PROFINET/Ethernet. It also supports communication with third-party controllers through OPC or other configured drivers in WinCC flexible.

    What engineering software is required to configure the 6AV6146-3MM41-0KY2?

    This panel is configured using Siemens WinCC flexible 2008 or later. Projects can be transferred to the panel via Ethernet, USB, or PROFIBUS connection from the engineering PC.

    What is the supply voltage for this HMI panel?

    The MP 377 operates on a 24 V DC supply voltage. Ensure the power source is adequately rated and properly filtered for industrial use.

    Can the MP 377 operate without a CompactFlash card?

    The panel can operate without a CompactFlash card for basic runtime functions, but a CompactFlash card is required for data logging, recipe storage, and extended project data. It is recommended to have one installed for full functionality.

    What is the IP protection rating of the front panel?

    The front panel of the MP 377 carries an IP65 protection rating, making it suitable for installation in environments where dust and water jets may be present. The rear of the unit is rated IP20.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector. Check that the supply is within tolerance and that the power connector is fully seated. Inspect for any blown internal fuses.

    Restore the 24 V DC supply to within specification. If supply voltage is correct and the display remains blank, the internal power supply board or backlight inverter may be faulty and require replacement or professional repair.

    Touchscreen does not respond or responds inaccurately

    Attempt to recalibrate the touchscreen via the panel's Start Center or Control Panel settings. Check for physical damage, contamination, or excessive pressure marks on the touch surface.

    Perform a touchscreen recalibration through the SIMATIC HMI Start Center. Clean the screen surface with a soft, dry cloth. If calibration fails repeatedly, the resistive touch overlay may be damaged and require replacement.

    HMI cannot communicate with the PLC over PROFIBUS

    Verify the PROFIBUS cable is correctly wired and terminated at both ends with 220-ohm termination resistors. Check that the HMI PROFIBUS address matches the configuration in the WinCC flexible project and that no address conflicts exist on the bus.

    Correct any wiring or termination issues. Ensure unique PROFIBUS addresses are assigned to all devices. Reload the WinCC flexible project to the panel if configuration changes were made.

    Panel freezes or runtime crashes unexpectedly

    Check the CompactFlash card for errors or insufficient free space. Review the system event log in WinCC flexible for recurring error events. Verify the panel operating temperature is within the 0-50 °C range.

    Replace or reformat the CompactFlash card if errors are detected. Ensure adequate ventilation around the panel. Perform a firmware update if a known software issue is identified. As a last resort, perform a factory reset and reload the project.

    Project transfer from PC to panel fails

    Confirm that the transfer channel (Ethernet or USB) is correctly configured in both the WinCC flexible project settings and the panel's Start Center transfer settings. Check firewall settings on the engineering PC that may block the transfer.

    Set the panel to transfer mode via the Start Center before initiating the download. Disable any PC firewall temporarily during transfer. Verify the IP address or PROFIBUS address settings match between the PC and the panel configuration.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart