• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6146-3MM40-0KY0 MP 377
    Awaiting product image

    Siemens 6AV6146-3MM40-0KY0 MP 377

    € 2.995,00

    Reset
    Clear
    SKU: 6AV6146-3MM40-0KY0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6146-3MM40-0KY0 is a Multi Panel (MP 377) belonging to the SIMATIC HMI family, designed for high-performance human-machine interface applications in industrial automation environments. This panel features a 15-inch widescreen TFT display and operates as a standalone visualization unit capable of handling complex process visualization tasks. It is part of Siemens' SIMATIC HMI MP 377 series, which represents a robust and versatile class of operator panels.

    The MP 377 (6AV6146-3MM40-0KY0) is equipped with a resistive touch screen and an integrated membrane keyboard, providing flexible operator input options. It supports multiple communication interfaces including PROFIBUS DP, PROFINET (Ethernet), and MPI, enabling seamless integration into a wide range of automation networks. The panel runs on Microsoft Windows CE and is configured using Siemens WinCC flexible engineering software. It offers 12 MB user memory for project data and supports USB ports for peripheral connectivity and data transfer. The operating voltage is 24 V DC, and the unit carries CE and UL certifications.

    The SIMATIC MP 377 is widely deployed in manufacturing, process industries, water and wastewater treatment, and energy management applications. Its combination of a large display, touch and key input, and broad communication capability makes it suitable for complex SCADA-level visualization at the machine or plant level. It is commonly integrated with Siemens S7-300 and S7-400 PLC systems as well as third-party controllers via standard protocols.

    Technical Specifications

    Display Size 15 inch
    Display Type TFT widescreen
    Display Colors 64,000 colors (16-bit)
    Touch Technology Resistive touch screen
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 40 W
    User Memory 12 MB
    Operating System Windows CE 6.0
    Communication Interface PROFIBUS DP, PROFINET (Ethernet RJ45), MPI, USB
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the HMI panel and the connected PLC or controller. Connection to the configured controller cannot be established or has been lost.
    Check PROFIBUS/MPI/PROFINET cabling and connectors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Tag read error. The HMI panel is unable to read a configured tag from the PLC.
    Verify the tag address in WinCC flexible matches the actual PLC data block or memory address. Check for PLC program changes that may have altered the address.
    Event ID: 10002
    Tag write error. The HMI panel is unable to write a value to a configured PLC tag.
    Check that the target PLC memory area is not write-protected. Verify the tag address and data type configuration in WinCC flexible.
    Event ID: 20000
    Project download error. A project transfer from the engineering PC to the HMI panel has failed.
    Ensure the transfer cable or network connection is intact. Verify that the HMI panel is in transfer mode and that the correct communication channel is selected in WinCC flexible.
    Event ID: 40000
    System memory low. Available memory for runtime operation is critically low.
    Reduce the project size by optimizing graphics, reducing the number of tags, or archiving historical data. Consider clearing the panel memory and reloading the project.
    Event ID: 50000
    Alarm buffer overflow. The alarm buffer has reached its maximum capacity and older alarms are being overwritten.
    Acknowledge and clear pending alarms. Configure alarm archiving to an external storage medium such as a USB drive or network share.
    Event ID: 70000
    Recipe data error. An error occurred during reading or writing of recipe data.
    Check the recipe configuration in WinCC flexible. Verify that the recipe data records are not corrupted and that sufficient memory is available for recipe storage.

    Frequently Asked Questions

    What engineering software is required to configure the MP 377 (6AV6146-3MM40-0KY0)?

    The MP 377 is configured using Siemens WinCC flexible 2008 or later. Projects are transferred to the panel via Ethernet, USB, or MPI/PROFIBUS connection.

    Which PLC systems are compatible with the SIMATIC MP 377?

    The MP 377 is compatible with Siemens S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, or PROFINET. It also supports third-party controllers through standard serial and Ethernet protocols.

    What is the display size and input method of the 6AV6146-3MM40-0KY0?

    This variant features a 15-inch widescreen TFT display with a resistive touch screen and an integrated membrane keyboard for operator input.

    What is the supply voltage for the MP 377 panel?

    The MP 377 operates on a 24 V DC supply voltage, which is standard for SIMATIC HMI panels in industrial cabinet installations.

    Can the MP 377 be used as a standalone SCADA visualization unit?

    Yes, the MP 377 supports complex process visualization with alarm management, trending, recipe handling, and data archiving, making it suitable for standalone machine-level or plant-level SCADA visualization.

    Troubleshooting

    Display remains blank after power on

    Measure 24 V DC supply voltage at the panel's power connector. Check that the supply polarity is correct and that the supply current capacity is sufficient (minimum 2 A recommended).

    Correct any wiring or polarity issues. If the supply voltage is correct but the display remains blank, the internal power supply or backlight inverter may be faulty and the panel should be sent for repair or replacement.

    Touch screen does not respond or responds inaccurately

    Attempt to recalibrate the touch screen through the Windows CE control panel or the SIMATIC HMI Start Center. Check for physical damage or contamination on the touch surface.

    Perform a touch screen recalibration. Clean the screen surface with a soft, dry cloth. If calibration does not resolve the issue, the touch screen digitizer may need replacement.

    HMI panel cannot communicate with the PLC

    Verify the communication cable connections on both the HMI and PLC sides. Check the configured PLC address, communication protocol, and baud rate in the WinCC flexible project against the actual PLC settings.

    Correct any address or protocol mismatches in the project configuration and reload the project. Replace the communication cable if continuity testing reveals a fault. Ensure the PROFIBUS terminating resistors are correctly set if using PROFIBUS DP.

    Panel repeatedly reboots or freezes during operation

    Check the 24 V DC supply for voltage drops or ripple under load. Review the Windows CE event log for application errors. Verify that the project is not exceeding the panel's memory or CPU resources.

    Stabilize the power supply and ensure adequate current capacity. Optimize the WinCC flexible project to reduce resource usage. If the issue persists, perform a factory reset of the panel and reload the project from a known-good backup.

    Project transfer from PC to panel fails

    Confirm that the panel is set to transfer mode via the SIMATIC HMI Start Center. Check the Ethernet or USB connection between the PC and the panel. Verify that the correct transfer channel is selected in WinCC flexible.

    Switch the panel to transfer mode manually. Replace the transfer cable if faulty. Ensure that any firewall or antivirus software on the PC is not blocking the WinCC flexible transfer process. Retry the transfer after confirming all settings match.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart