• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6146-1RQ01-1LY5 SIMATIC MP 377
    Awaiting product image

    Siemens 6AV6146-1RQ01-1LY5 SIMATIC MP 377

    € 3.495,00

    Reset
    Clear
    SKU: 6AV6146-1RQ01-1LY5 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6146-1RQ01-1LY5 is a Multi Panel belonging to the SIMATIC MP 377 series, part of Siemens' SIMATIC HMI product line. This panel is a high-performance operator interface device designed for demanding industrial visualization and control tasks. It runs the Windows CE operating system and is engineered for use with Siemens WinCC flexible runtime software.

    The MP 377 panel features a 15-inch TFT widescreen display with a resolution of 1024 x 768 pixels and 64,000 colors, providing clear and detailed process visualization. It is equipped with a resistive touch screen as well as function keys, offering flexible operator input options. Communication interfaces include PROFIBUS DP, PROFINET (Ethernet), USB ports, and an MPI interface, enabling seamless integration into a wide range of automation architectures. The panel includes 12 MB of user memory for project data and supports CF card slots for extended storage. Its robust industrial-grade housing is rated IP65 on the front face, protecting against dust and water ingress.

    The SIMATIC MP 377 is widely deployed in manufacturing, process industries, automotive production, and energy management applications. Its combination of a large display, versatile communication options, and compatibility with Siemens S7-300 and S7-400 PLCs makes it suitable for complex SCADA and HMI applications requiring detailed process overviews. The panel is also used in water treatment, chemical processing, and machine tool environments where reliable long-term operation is essential.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels
    Display Colors 64,000 colors
    Display Type TFT
    Touch Technology Resistive touch screen
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 60 W
    Operating System Windows CE 6.0
    User Memory 12 MB
    Communication Interface PROFIBUS DP, PROFINET (Ethernet), MPI, USB
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC MP 377

    Common Error Codes & System Events

    Event ID: 10000
    Connection to PLC lost or communication timeout detected between the HMI panel and the configured controller.
    Check PROFIBUS/PROFINET cabling and connector integrity. Verify PLC is powered and running. Confirm communication parameters (address, baud rate) match in WinCC flexible project.
    Event ID: 10001
    Connection to PLC established after a previous communication failure.
    Informational event. No corrective action required. Monitor for recurring disconnections which may indicate network instability.
    Event ID: 20000
    Tag read error — the HMI was unable to read a configured tag from the controller.
    Verify the tag address exists in the PLC program and has not been modified. Check that the data block or memory area referenced is accessible and correctly configured in WinCC flexible.
    Event ID: 40000
    Project download error — a fault occurred during project transfer to the panel.
    Ensure the correct transfer channel is selected and the panel is in transfer mode. Check USB or Ethernet cable connection. Verify WinCC flexible version compatibility with the panel firmware.
    Event ID: 70010
    Backup/restore error — an error occurred during data backup or restore operation via CF card or USB.
    Check that the CF card or USB storage device is properly inserted and has sufficient free space. Verify the storage medium is not write-protected or corrupted.
    Event ID: 50000
    Alarm logging error — the HMI was unable to write alarm records to the configured data storage location.
    Check available storage space on the CF card or internal memory. Verify alarm logging configuration in WinCC flexible and ensure the target path is valid and accessible.
    Event ID: 60000
    Recipe data error — a fault occurred when reading or writing recipe data.
    Verify recipe configuration in WinCC flexible. Ensure the target storage medium is available and not full. Check that recipe tag addresses are correctly mapped to the PLC.

    Frequently Asked Questions

    Which PLC families is the SIMATIC MP 377 compatible with?

    The MP 377 is compatible with Siemens S7-300, S7-400, S7-1200, and S7-1500 PLCs via MPI, PROFIBUS DP, or PROFINET interfaces. It can also communicate with third-party controllers using supported drivers in WinCC flexible.

    What software is required to program and configure the MP 377?

    The panel is configured using Siemens WinCC flexible 2008 or later. Projects are created on a PC and transferred to the panel via Ethernet, USB, or MPI/PROFIBUS connection.

    What is the input voltage requirement for the 6AV6146-1RQ01-1LY5?

    The panel requires a 24 V DC power supply. Ensure the supply is capable of providing sufficient current to meet the panel's maximum power consumption of approximately 60 W.

    Can the MP 377 panel be used outdoors?

    The MP 377 is rated IP65 on the front face, providing protection against dust and water jets, but it is not designed for direct outdoor exposure to sunlight or extreme weather without additional protective enclosure measures.

    What storage expansion options are available on the MP 377?

    The MP 377 supports CompactFlash (CF) cards for extended project and data storage, as well as USB ports for connecting USB storage devices or peripherals.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector. Check that the supply current is sufficient. Inspect the panel for any visible damage to the power input terminals.

    Ensure the 24 V DC supply is stable and within tolerance. If the supply is correct and the display remains blank, the internal power supply board or backlight inverter may be faulty and require replacement.

    Touch screen does not respond or responds inaccurately

    Attempt to operate the panel using the physical function keys to determine if the issue is isolated to the touch screen. Check for physical damage or contamination on the screen surface.

    Perform a touch screen recalibration through the panel's Start Center or Control Panel settings. Clean the screen surface with a soft, dry cloth. If recalibration does not resolve the issue, the touch screen overlay may need to be replaced.

    Panel cannot establish communication with the PLC

    Verify the communication cable connections on both the panel and PLC sides. Check the configured communication parameters (IP address, PROFIBUS address, baud rate) in the WinCC flexible project against the PLC settings.

    Correct any mismatched communication parameters and re-download the project. Replace faulty cables or connectors. Ensure the PLC is in RUN mode and that the network is free of address conflicts.

    Project transfer fails from engineering PC to panel

    Confirm the panel is in Transfer mode via the Start Center. Check the connection type selected in WinCC flexible matches the physical connection being used (USB, Ethernet, or MPI).

    Restart the panel into Transfer mode and retry the download. Verify firewall settings on the engineering PC are not blocking the transfer. Ensure WinCC flexible runtime version on the panel is compatible with the project version.

    Panel reboots unexpectedly or freezes during operation

    Check the 24 V DC supply for voltage drops or instability under load. Review the system event log on the panel for recorded fault events prior to the reboot. Check for overheating by verifying ambient temperature and ventilation around the panel.

    Stabilize the power supply and ensure adequate ventilation. If the issue persists, back up the project and perform a factory reset of the panel, then re-download the project. Persistent instability may indicate a hardware fault requiring panel repair or replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart