Siemens 6AV5040-1BF12-1AA0 SIMATIC OP 40
€ 1.830,00
The Siemens 6AV5040-1BF12-1AA0 is an Operator Panel (OP 40) belonging to the SIMATIC HMI family, designed for human-machine interface applications in industrial automation environments. This unit provides a monochrome LCD display with a membrane keypad for operator interaction and process visualization. It is a compact, panel-mounted device intended for use with Siemens SIMATIC S5 and S7 programmable logic controllers.
The OP 40 features a built-in LCD display with a resolution suited for text and simple graphic representation, along with a full alphanumeric membrane keypad for data entry and navigation. It supports serial communication interfaces, including TTY and RS-232/RS-485, enabling connectivity to a range of Siemens PLCs and compatible controllers. The device operates on a 24 V DC supply and is built to withstand the demands of industrial environments, with a front panel protection rating of IP 65.
The SIMATIC OP 40 is widely used in manufacturing, process control, and machine automation applications where a reliable and straightforward operator interface is required. It is particularly suited for machine tools, conveyor systems, packaging machinery, and general factory automation where operators need to monitor process values, enter setpoints, and acknowledge alarms. Its robust construction and compatibility with the SIMATIC controller range make it a practical choice for retrofit and new installation projects.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Size | 5.5 inch |
| Keypad Type | Membrane keypad, alphanumeric |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 10 W |
| Communication Interface | TTY (20 mA), RS-232, RS-485 |
| IP/Protection Rating | IP 65 (front panel) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +70 °C |
| Relative Humidity | 10% to 90%, non-condensing |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC OP 40 |
| Certifications | CE, UL |
| PLC Compatibility | SIMATIC S5, SIMATIC S7 |
Common Error Codes & System Events
- System Error 1
- Communication error between the OP 40 and the connected PLC. The connection has been interrupted or cannot be established.
Check the communication cable and connector integrity. Verify the interface settings (baud rate, address) match the PLC configuration. Restart the OP 40. - System Error 2
- Configuration data error. The project data loaded on the device is corrupted or incompatible with the current firmware version.
Reload the project configuration using ProTool or the appropriate configuration software. Verify firmware and project version compatibility. - System Error 3
- Memory error detected. Internal memory checksum failure or insufficient memory for the loaded project.
Perform a memory reset and reload the project. If the error persists, the internal memory module may need replacement. - System Error 4
- Watchdog timeout. The device has detected a processor or communication watchdog fault.
Cycle power to the OP 40. If the fault recurs, check for electrical interference on the power supply and communication lines. - PLC Not Responding
- The OP 40 cannot receive a response from the connected PLC within the configured timeout period.
Verify PLC is powered and in RUN mode. Check all cable connections and interface parameters. Confirm the PLC program includes the required communication blocks. - Receive Error
- A data receive error has occurred on the serial communication interface, indicating corrupted or incomplete data frames.
Check cable shielding and grounding. Verify baud rate and parity settings on both the OP 40 and the PLC. Replace the communication cable if necessary. - Configuration Error
- The device has detected a mismatch between the loaded configuration and the connected PLC type or version.
Review the project configuration in ProTool and ensure the correct PLC type and MPI/serial address are selected. Reload the corrected project to the OP 40.
Frequently Asked Questions
Which PLCs are compatible with the SIMATIC OP 40 (6AV5040-1BF12-1AA0)?
The OP 40 is compatible with Siemens SIMATIC S5 and SIMATIC S7 series PLCs. Communication is established via TTY (20 mA current loop), RS-232, or RS-485 serial interfaces depending on the PLC and cable used.
What configuration software is used to program the OP 40?
The OP 40 is configured using Siemens ProTool software. Projects are created on a PC and then transferred to the device via a serial programming cable.
What is the supply voltage for the 6AV5040-1BF12-1AA0?
The device requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range for reliable operation.
What is the front panel protection rating of the OP 40?
The front panel of the OP 40 carries an IP 65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for most industrial panel installations.
Can the OP 40 display graphical content?
The OP 40 is primarily a text-based operator panel. It supports limited graphical elements but is mainly intended for displaying alphanumeric process values, messages, and alarm texts rather than complex graphics.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the supply is within tolerance and the connector is fully seated. Inspect the internal fuse if accessible.
Restore correct supply voltage. Replace the fuse if blown. If the display remains blank with correct supply, the backlight or internal power supply board may require replacement.
OP 40 displays 'PLC Not Responding' or communication error on startup
Verify the communication cable is correctly connected between the OP 40 and the PLC. Check that the baud rate, parity, and station address configured in the OP 40 project match the PLC settings.
Correct any mismatched communication parameters in the ProTool project and reload it to the device. Replace the communication cable if damaged. Confirm the PLC is powered and in RUN mode.
Keypad buttons do not respond or respond intermittently
Inspect the membrane keypad for physical damage, contamination, or deformation. Check the internal ribbon cable connection between the keypad and the main PCB.
Clean the keypad surface. If the ribbon cable is loose, reseat it carefully. A damaged membrane keypad will require replacement of the keypad assembly.
Configuration cannot be transferred from PC to OP 40
Verify the programming cable type and COM port settings on the PC. Confirm ProTool is set to the correct transfer interface and baud rate. Check that the OP 40 is in transfer mode.
Place the OP 40 in transfer mode via the system menu. Use the correct Siemens programming cable for the OP 40. Adjust COM port settings in ProTool to match the cable and device requirements.
Alarm messages are not displayed or are displayed incorrectly
Review the alarm configuration in the ProTool project. Check that the PLC data areas mapped to alarm bits match the actual PLC program addresses.
Correct the alarm bit addresses in the ProTool configuration to match the PLC program. Reload the updated project to the OP 40 and verify alarm triggering in the PLC program.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page