Siemens 6AV5030-1EL20-0BA0 SIMATIC HMI TP 270
€ 1.525,00
The Siemens 6AV5030-1EL20-0BA0 is a Touch Panel operator interface belonging to the SIMATIC HMI TP 270 series, manufactured by Siemens. It is a panel-mounted human-machine interface designed for machine-level visualization and operator control in industrial automation environments. The unit integrates a color TFT touchscreen display with a built-in processor, providing a standalone HMI solution configurable via SIMATIC WinCC flexible software.
The TP 270 features a 10.4-inch TFT color display with a resolution of 640 x 480 pixels (VGA) and supports 256 colors. It is equipped with a resistive touch interface and offers communication via MPI, PROFIBUS DP, and serial interfaces, enabling direct connection to SIMATIC S7 PLCs as well as third-party controllers. The panel operates on a 24 V DC supply and includes onboard flash memory for project storage, with support for external memory cards for project backup and transfer. The unit runs on Windows CE and supports recipe management, alarm logging, and trend display functions.
The SIMATIC TP 270 10" is widely deployed in machine tool, packaging, food and beverage, and general manufacturing applications where a robust, mid-range HMI with color visualization is required. Its compatibility with the SIMATIC S7-200, S7-300, and S7-400 controller families makes it a standard choice for Siemens-based automation systems. The panel's industrial-grade construction and IP65 front protection rating make it suitable for installation in control cabinet doors and operator panels in demanding production environments.
Technical Specifications
| Display Size | 10.4 inch |
|---|---|
| Display Resolution | 640 x 480 pixels (VGA) |
| Display Colors | 256 colors |
| Display Type | TFT color LCD |
| Touch Technology | Resistive |
| Input/Operating Voltage | 24 V DC |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90%, non-condensing |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Communication Interface | MPI, PROFIBUS DP, RS-232, RS-422/485 |
| Operating System | Windows CE |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC HMI TP 270 |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between HMI panel and PLC. Connection to the configured controller cannot be established.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the HMI project configuration. - Event ID: 10001
- Connection to PLC lost during runtime operation.
Inspect communication cables for damage or loose connectors. Verify PLC is powered and running. Check for address conflicts on the network. - Event ID: 20000
- Project download error. Transfer of the HMI project from the engineering PC to the panel failed.
Ensure the panel is in Transfer mode. Verify the communication cable and PC interface settings. Check available flash memory on the panel. - Event ID: 40000
- Tag read/write error. A configured variable could not be read from or written to the PLC.
Verify the PLC data block and address referenced in the HMI project exist and are accessible. Check PLC program for address changes. - Event ID: 50000
- Insufficient memory for project or runtime data. Panel flash or RAM is nearly full.
Delete unused projects or log files from the panel memory. Reduce the size of the HMI project or use an external memory card. - Event ID: 60000
- System error during panel startup or runtime. Internal software fault detected.
Perform a panel restart. If the error persists, reload the HMI project via WinCC flexible and update the panel firmware to the latest compatible version. - Event ID: 70000
- Recipe data error. Recipe records could not be read or written correctly.
Check recipe configuration in WinCC flexible. Verify sufficient memory is available and that recipe data files are not corrupted. Re-transfer the project if necessary.
Frequently Asked Questions
Which engineering software is used to configure the TP 270 10"?
The SIMATIC TP 270 is configured using Siemens SIMATIC WinCC flexible software. Projects are downloaded to the panel via MPI, PROFIBUS DP, or a serial PC/PPI cable.
Which Siemens PLCs are compatible with the 6AV5030-1EL20-0BA0?
The panel is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It also supports connections to third-party controllers via serial communication protocols.
What is the supply voltage for this HMI panel?
The panel operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to avoid operational issues.
What is the front protection rating of the TP 270?
The front panel carries an IP65 protection rating, making it resistant to dust ingress and water jets, suitable for installation in control cabinet doors in industrial environments.
Can the HMI project be backed up using a memory card?
Yes, the TP 270 supports external memory cards for project backup and transfer. This allows projects to be copied between panels without requiring a PC connection.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the panel power connector. Check for correct polarity. Inspect internal fuse if accessible.
Restore correct 24 V DC supply voltage. If the backlight has failed, the backlight unit or the entire panel may require replacement, as the backlight is not a field-replaceable component on this model.
Touchscreen does not respond or responds inaccurately
Determine whether the issue is a complete lack of response or positional inaccuracy. Check for physical damage or contamination on the touch surface.
Perform a touchscreen recalibration via the panel's Start Center or Control Panel menu. Clean the touch surface with a soft, dry cloth. If recalibration does not resolve the issue, the touch foil may require replacement.
Panel fails to communicate with the PLC
Verify the MPI or PROFIBUS DP address configured in the HMI project matches the physical PLC address. Check cable connections, termination resistors at both ends of the bus, and baud rate settings.
Correct any address or baud rate mismatches in the WinCC flexible project and re-download. Replace damaged communication cables and ensure proper bus termination is applied at both ends of the network.
HMI project cannot be transferred from PC to panel
Confirm the panel is set to Transfer mode via the Start Center. Check the communication interface selected in WinCC flexible matches the physical connection (MPI, PROFIBUS, or serial).
Switch the panel to Transfer mode manually. Verify PC interface adapter settings and cable integrity. Ensure the WinCC flexible version is compatible with the panel firmware version; update firmware if necessary.
Panel displays 'Updating operating system' loop or fails to boot
This may indicate corrupted firmware or an incomplete previous firmware update. Check if a memory card with incorrect data is inserted.
Remove any inserted memory card and attempt a restart. If the panel remains in a boot loop, perform a firmware recovery using the Siemens ProSave tool via a serial or MPI connection to reload the operating system image.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page