Siemens 6AV5030-1EL20-0AA0 SIMATIC WinCC flexible
€ 1.830,00
The Siemens 6AV5030-1EL20-0AA0 is a software license for SIMATIC WinCC flexible 2008 Standard, part of Siemens' SIMATIC HMI software portfolio. WinCC flexible is a scalable engineering and runtime software platform designed for configuring and operating HMI panels and PC-based visualization systems within the SIMATIC automation environment. This particular SKU represents the Standard edition, which provides a comprehensive set of tools for developing operator interfaces across a wide range of panel types.
WinCC flexible 2008 Standard supports engineering for the full range of SIMATIC HMI panels including Micro Panels, Mobile Panels, Operator Panels, Multi Panels, and PC-based systems. The software provides a project-oriented engineering environment with features such as faceplates, library management, multi-language project support, and integrated simulation for offline testing without physical hardware. It supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS, and Ethernet interfaces, and includes tools for alarm management, trend displays, recipe management, and user administration.
WinCC flexible Standard is widely used in manufacturing, process automation, machine building, and plant engineering applications where a mid-range HMI engineering tool is required. It is suitable for machine-level visualization projects that require more capability than the Compact edition but do not require the full Advanced feature set. Industries such as automotive, food and beverage, packaging, and general factory automation commonly deploy this software for configuring operator panels on production lines and standalone machines.
Technical Specifications
| Software Edition | Standard |
|---|---|
| Software Version | WinCC flexible 2008 |
| License Type | Single license (full version) |
| Compatible HMI Panels | SIMATIC Micro Panels, OP/TP series, Mobile Panels, Multi Panels |
| PLC Compatibility | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces Supported | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Operating System | Windows XP Professional, Windows Vista, Windows 7 |
| Series/Product Family | SIMATIC WinCC flexible 2008 |
| Simulation | Integrated offline simulator included |
| Language Support | Multi-language project engineering supported |
| Recipe Management | Supported |
| Alarm Management | Supported |
| Certifications | CE |
Common Error Codes & System Events
- Event ID: 1000020
- Connection to PLC lost or communication timeout occurred between WinCC flexible runtime and the configured controller.
Check physical network or fieldbus connections, verify PLC is powered and running, confirm communication parameters (IP address, MPI address, baud rate) match the project configuration. - Event ID: 1000022
- Tag read/write error — a configured tag could not be read from or written to the PLC.
Verify the tag address exists in the PLC program, check data type consistency between HMI tag and PLC variable, and confirm the PLC is in RUN mode. - Event ID: 1000040
- License not found or license validation failed for WinCC flexible runtime.
Ensure the correct WinCC flexible runtime license is installed on the target device. Use the Automation License Manager to verify and transfer the license. - Event ID: 1000060
- Project transfer failed — download of the HMI project to the target panel was unsuccessful.
Check the transfer cable or network connection, confirm the panel is in Transfer mode, verify the correct communication channel is selected in the transfer settings. - Event ID: 1000080
- Insufficient memory on target HMI device — project size exceeds available flash or RAM on the panel.
Reduce project size by optimizing graphics, removing unused elements, or compressing images. Consider upgrading to a panel with greater memory capacity. - Event ID: 1000100
- Script runtime error — a configured VB script or function within the project encountered an execution error.
Review the script logic in the WinCC flexible engineering environment, check for division by zero, null references, or unsupported functions, and test using the integrated simulator. - Event ID: 1000120
- Alarm buffer overflow — the number of pending alarms exceeded the configured alarm buffer size.
Increase the alarm buffer size in the project settings, ensure alarms are being acknowledged and cleared by the operator, and review alarm configuration for excessive triggering conditions.
Frequently Asked Questions
Which SIMATIC HMI panels can be configured using WinCC flexible 2008 Standard?
WinCC flexible 2008 Standard supports engineering for SIMATIC Micro Panels, OP/TP Operator and Touch Panels, Mobile Panels, and Multi Panels. It does not support configuration of SIMATIC Basic Panels, which require TIA Portal with WinCC Basic.
Is WinCC flexible 2008 compatible with the TIA Portal engineering environment?
No, WinCC flexible 2008 is a standalone engineering tool and is not integrated into TIA Portal. Siemens introduced TIA Portal as the successor platform; projects created in WinCC flexible can be migrated to TIA Portal WinCC using the migration tool provided by Siemens.
What PLCs can communicate with an HMI project created in WinCC flexible Standard?
WinCC flexible Standard supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet. Third-party PLC communication is also possible via OPC or specific driver packages.
Does WinCC flexible 2008 Standard include a runtime license for PC-based visualization?
The engineering software license (6AV5030-1EL20-0AA0) covers project configuration only. A separate WinCC flexible Runtime license is required to run projects on a PC-based system; panel-based HMI devices include their own runtime environment.
Can WinCC flexible projects be simulated without a physical HMI panel?
Yes, WinCC flexible 2008 includes an integrated simulator that allows offline testing of HMI projects on the engineering PC without requiring a physical panel or PLC connection.
Troubleshooting
WinCC flexible software fails to install or installation aborts with an error
Check Windows event logs for the specific installation error code. Verify that the operating system version is supported (Windows XP Professional SP3, Windows Vista, or Windows 7) and that the Automation License Manager is installed correctly.
Ensure all prerequisites listed in the WinCC flexible readme are installed, including the correct .NET Framework version and Microsoft SQL Server components. Run the installer as Administrator and disable antivirus software temporarily during installation.
Project cannot be transferred to the HMI panel — transfer connection fails
Confirm the panel is set to Transfer mode (accessible via the panel's Start Center or Control Panel). Check the selected transfer channel in WinCC flexible matches the physical connection (Ethernet, USB, or serial MPI/PROFIBUS).
Verify IP address or MPI address settings match between the engineering PC and the panel. For Ethernet transfers, ensure both devices are on the same subnet. For USB transfers, confirm the correct USB driver for the panel is installed on the PC.
Runtime communication alarm appears on the HMI panel indicating PLC connection lost
Check the physical connection between the HMI panel and the PLC (cable integrity, switch/hub status). Verify PLC is powered and in RUN mode. Compare the communication parameters configured in the HMI project against the actual PLC settings.
Correct any mismatched parameters such as IP address, MPI node address, or PROFIBUS baud rate in the WinCC flexible project and retransfer. Replace faulty cables or connectors as needed.
Alarm or tag values are not updating on the HMI display during runtime
Use the WinCC flexible simulator or the panel's diagnostic functions to check tag communication status. Verify the PLC data block or memory address referenced by the HMI tag exists and is accessible.
Correct tag addresses in the WinCC flexible project to match the actual PLC program. Ensure the PLC program is writing to the expected data areas and that no access protection is blocking the HMI connection.
WinCC flexible engineering software reports 'No valid license found' on startup
Open the Siemens Automation License Manager and check whether a valid WinCC flexible Standard license is present and not expired or transferred away from this PC.
Transfer a valid license to the engineering PC using the Automation License Manager. If the license was stored on a USB dongle or another machine, reconnect the dongle or transfer the license back. Contact Siemens support if the license has been corrupted.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page