Siemens 6AV3688-3AA03-0AX0 OP 73micro
€ 502,00
The Siemens OP 73micro (part number 6AV3688-3AA03-0AX0) is a compact operator panel belonging to the SIMATIC HMI Micro Panel family. It is designed for simple machine-level operator control and monitoring tasks, providing a cost-effective interface solution for basic automation applications. The unit is a text-based display panel without touchscreen functionality, intended for use with Siemens SIMATIC S7-200 PLCs.
The OP 73micro features a monochrome LCD display capable of showing two lines of text, with a resolution of 4 x 20 characters. It is equipped with a membrane keypad for operator input, including function keys and navigation keys. The panel communicates via a PPI/MPI interface, allowing direct connection to S7-200 controllers. It operates on a 24 V DC supply and is rated IP65 on the front face, making it suitable for panel-mount installations in industrial environments.
The OP 73micro is typically deployed in small machinery, conveyor systems, packaging equipment, and simple process control applications where basic text-based status display and operator input are sufficient. Its compact dimensions and low cost make it well suited for OEM machine builders who require a straightforward HMI solution without the overhead of a graphical panel. The panel is commonly found in industries such as food and beverage, material handling, and general manufacturing.
Technical Specifications
| Display Type | Monochrome LCD |
|---|---|
| Display Format | 4 x 20 characters (2 lines visible) |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | PPI / MPI (RS-485) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10 % to 90 % (non-condensing) |
| Mounting | Panel mount |
| Certifications | CE, UL |
| Compatible Controllers | SIMATIC S7-200 |
| Input Keys | Membrane keypad with function and navigation keys |
| Series/Product Family | SIMATIC HMI Micro Panel |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the OP 73micro and the connected PLC. The panel cannot establish or maintain a connection to the S7-200 controller.
Check the RS-485 cable connections and termination resistors. Verify the PPI communication parameters (baud rate, station address) match the PLC configuration. Ensure the PLC is powered and in RUN mode. - Event ID: 10001
- Timeout error during communication with the PLC. The panel sent a request but did not receive a response within the expected time.
Check cable integrity and connector pins. Reduce cable length or verify shielding. Confirm PLC program is running and not in STOP mode. - Event ID: 20000
- Configuration error detected. The project loaded on the panel is incompatible with the connected PLC or the panel firmware version.
Re-download the project using SIMATIC WinCC flexible or ProTool. Verify the project was compiled for the correct panel type and firmware version. - Event ID: 20001
- Project download failed or project memory is corrupted.
Perform a factory reset on the panel and re-download the project. Check available memory and ensure the project file is not corrupted. - Event ID: 30000
- Undervoltage detected on the 24 V DC supply line.
Measure the supply voltage at the panel connector. Ensure the power supply provides a stable 24 V DC within the specified tolerance. Replace the power supply if necessary. - Event ID: 40000
- Tag or variable address not found in the PLC. The panel is attempting to read or write a data address that does not exist in the PLC program.
Verify the variable addresses configured in the HMI project match the actual data block or memory addresses in the PLC program. Recompile and download the project after corrections.
Frequently Asked Questions
Which PLCs are compatible with the OP 73micro (6AV3688-3AA03-0AX0)?
The OP 73micro is designed for use exclusively with Siemens SIMATIC S7-200 PLCs via the PPI/MPI (RS-485) interface. It is not compatible with S7-300, S7-400, or S7-1200 controllers without additional configuration considerations.
What software is used to configure and program the OP 73micro?
The OP 73micro is configured using Siemens SIMATIC WinCC flexible Micro or the older ProTool/Lite engineering software. Projects are downloaded to the panel via the RS-485 programming cable.
What is the front panel protection rating of the OP 73micro?
The front face of the OP 73micro is rated IP65, making it resistant to dust ingress and low-pressure water jets, suitable for panel-mount installations in industrial environments.
Can the OP 73micro display graphical content or images?
No, the OP 73micro is a text-based operator panel only. It displays alphanumeric characters and does not support graphical content, bitmaps, or trend displays.
What is the supply voltage required for the OP 73micro?
The OP 73micro requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range to guarantee reliable operation.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the panel power connector using a multimeter. Verify the power supply is functional and within tolerance.
If supply voltage is correct, perform a panel reset by holding the appropriate key combination during power-up. If the display remains blank, the internal LCD or power regulation circuit may be faulty and the panel should be sent for repair or replacement.
Panel shows communication error and cannot connect to S7-200 PLC
Inspect the RS-485 cable between the panel and the PLC for damage, loose connectors, or incorrect wiring. Verify that the PPI baud rate and station address settings on the panel match those configured in the PLC.
Replace or reseat the communication cable. Correct any mismatched communication parameters in the HMI project and re-download. Ensure termination resistors are correctly placed at both ends of the RS-485 bus if multiple devices are connected.
Operator keys do not respond or are intermittently unresponsive
Inspect the membrane keypad surface for physical damage, contamination, or deformation. Test each key systematically using a diagnostic screen if available in the project.
Clean the keypad surface with a dry cloth. If keys remain unresponsive, the membrane keypad assembly may be worn or damaged and requires replacement. Contact a repair specialist for keypad replacement on this panel.
Project download fails from engineering PC to the panel
Verify the correct programming cable is being used (PC-PPI cable or USB-PPI adapter). Check that the COM port settings in WinCC flexible match the cable and that the panel is in transfer mode.
Set the panel to transfer mode manually via the panel menu. Reinstall the USB-PPI driver if using a USB adapter. Try a different USB port or cable. Ensure the WinCC flexible project is compiled without errors before attempting the download.
Displayed values are incorrect or do not update
Check the variable address mapping in the WinCC flexible project against the actual PLC data addresses. Verify the PLC program is writing to the correct memory locations.
Correct any address mismatches in the HMI project configuration and re-download the project to the panel. Confirm the PLC program logic is executing correctly and updating the relevant data registers.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page