• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6645-0BB01-0AX0 SIMATIC MP 277
    Siemens 6AV6645-0BB01-0AX0 SIMATIC MP 277

    Siemens 6AV6645-0BB01-0AX0 SIMATIC MP 277

    € 1.200,00 – € 3.300,00Price range: € 1.200,00 through € 3.300,00

    Reset
    Clear
    SKU: 6AV6645-0BB01-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens SIMATIC MP 277 (part number 6AV6645-0BB01-0AX0) is a multi-panel human-machine interface belonging to the SIMATIC HMI Multi Panel family. It features an 8-inch widescreen TFT display and is designed for machine-level visualization and operator control in industrial automation environments. This panel runs on the Windows CE 6.0 operating system and is configured using Siemens WinCC flexible engineering software.

    The 6AV6645-0BB01-0AX0 variant is equipped with a resistive touch screen and an additional membrane keypad for operator input flexibility. It supports multiple communication interfaces including PROFIBUS DP and Ethernet (PROFINET), enabling integration with a wide range of Siemens and third-party controllers. The panel provides 12 MB of user memory for project data and includes a USB interface and a CompactFlash card slot for data storage and project transfer. The unit operates on a 24 V DC supply and carries CE and UL certifications.

    The SIMATIC MP 277 is widely deployed in machine building, automotive manufacturing, food and beverage processing, and general industrial automation. Its combination of touch and key operation makes it suitable for applications requiring both graphical visualization and direct function key access. The panel's robust construction and broad communication capability make it a reliable choice for demanding production environments where operator interface reliability is critical.

    Technical Specifications

    Display Size 8 inch (widescreen)
    Display Type TFT color LCD
    Display Resolution 800 x 480 px
    Display Colors 65,536 colors
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Power Consumption Approx. 15 W
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Communication Interface PROFIBUS DP, Ethernet (PROFINET), USB
    User Memory 12 MB
    Storage Expansion CompactFlash card slot
    Operating System Windows CE 6.0
    IP Protection Rating IP65 (front), IP20 (rear)
    Certifications CE, UL
    Mounting Panel mounting

    Common Error Codes & System Events

    Event ID: 1000
    Connection to the PLC could not be established or was interrupted.
    Check PROFIBUS or Ethernet cable connections and verify PLC address settings in the project configuration. Ensure the PLC is powered and running.
    Event ID: 1003
    Tag read error — the HMI panel cannot read a configured tag from the controller.
    Verify the tag address in WinCC flexible matches the actual PLC data block or memory address. Check communication link integrity.
    Event ID: 1004
    Tag write error — the HMI panel cannot write a value to the configured controller tag.
    Check that the target PLC address is not write-protected and that the data type matches the configured tag. Verify communication is active.
    Event ID: 10000
    System memory low — available runtime memory is insufficient for the current project.
    Reduce project complexity, remove unused screens or scripts, and restart the panel. Consider archiving data to CompactFlash card.
    Event ID: 10001
    Project transfer failed — an error occurred during project download from the engineering PC.
    Verify USB or Ethernet connection between engineering PC and panel. Ensure WinCC flexible version is compatible with the panel firmware version.
    Event ID: 20000
    Panel operating system error or runtime crash detected.
    Perform a controlled restart of the panel. If the fault persists, reload the panel firmware using ProSave or WinCC flexible and re-transfer the project.
    Event ID: 40000
    Recipe data error — recipe records could not be read from or written to storage.
    Check CompactFlash card integrity and available storage space. Re-initialize the recipe data storage if necessary.

    Frequently Asked Questions

    What communication interfaces does the 6AV6645-0BB01-0AX0 support?

    The SIMATIC MP 277 8-inch panel supports PROFIBUS DP and Ethernet (PROFINET) for PLC communication, as well as USB interfaces for project transfer and peripheral devices. A CompactFlash card slot is also available for data storage.

    Which engineering software is used to configure this HMI panel?

    The panel is configured using Siemens WinCC flexible 2008 or later. It is not compatible with the newer TIA Portal WinCC Advanced software without migration.

    Is this panel compatible with Siemens S7-300 and S7-400 PLCs?

    Yes, the SIMATIC MP 277 supports direct communication with S7-300 and S7-400 PLCs via PROFIBUS DP or Ethernet, as well as S7-200 PLCs via the appropriate communication driver.

    What is the input voltage requirement for this panel?

    The panel requires a 24 V DC power supply. It is recommended to use a regulated power supply with sufficient current capacity, typically at least 1 A.

    Can the panel be operated by touch input alone?

    Yes, the resistive touchscreen allows full operation without the membrane keypad. However, the keypad provides additional function keys that can be assigned to specific project actions for faster operator interaction.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power supply terminals. Verify the power connector is fully seated. Measure voltage at the panel input connector.

    Restore correct 24 V DC supply. If voltage is present but display remains blank, the internal backlight or power supply board may be faulty and require replacement.

    Touchscreen does not respond or responds inaccurately

    The resistive touchscreen may be miscalibrated or the touch surface may be damaged. Access the calibration utility via the Control Panel in the Windows CE Start menu.

    Recalibrate the touchscreen using the built-in calibration tool. If calibration does not resolve the issue, inspect the touch overlay for physical damage and replace if necessary.

    Panel fails to establish communication with the PLC

    Verify the PROFIBUS address or IP address configured on the panel matches the project settings. Check cable connections and network switch or PROFIBUS termination resistors.

    Correct the communication parameters in WinCC flexible and re-transfer the project. Replace the communication cable if continuity testing reveals a fault.

    Project transfer from engineering PC fails

    Confirm the USB or Ethernet connection between the PC and panel is active. Check that the panel is in Transfer mode and that the WinCC flexible version matches the panel firmware.

    Switch the panel to Transfer mode via the Start Center. Update panel firmware using ProSave if version mismatch is detected, then retry the project transfer.

    Panel restarts unexpectedly or freezes during operation

    This may indicate insufficient project memory, a corrupted project file, or a hardware fault. Check the system event log in the panel's Control Panel for recorded event IDs.

    Optimize the project to reduce memory usage. Re-transfer a clean project backup. If the issue persists, reload the panel firmware via ProSave and restore the project from a known good backup.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart