• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV3617-1JC20-0AX1 OP17
    Siemens 6AV3617-1JC20-0AX1 OP17

    Siemens 6AV3617-1JC20-0AX1 OP17

    € 662,00 – € 820,00Price range: € 662,00 through € 820,00

    Reset
    Clear
    SKU: 6AV3617-1JC20-0AX1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens OP17 (part number 6AV3617-1JC20-0AX1) is a compact operator panel belonging to the SIMATIC HMI family. It is designed for machine-level human-machine interface applications, providing text-based display and keyboard input for process visualization and control. The OP17 is a member of the SIMATIC OP series, intended for use with Siemens SIMATIC S5 and S7 programmable logic controllers.

    The 6AV3617-1JC20-0AX1 features a 4-line LCD text display capable of showing up to 20 characters per line, with a membrane keypad for operator input including function keys and system keys. It supports multiple communication interfaces including MPI, PROFIBUS-DP, and point-to-point serial connections, enabling flexible integration into existing automation networks. The panel operates on 24 V DC supply voltage and is designed for panel mounting with a protection rating of IP65 on the front face. Configuration is performed using the ProTool software package.

    The OP17 is widely used in manufacturing, packaging, and process automation environments where a cost-effective, robust text-based operator interface is required. It is suitable for machine tools, conveyor systems, and general industrial machinery where operators need to monitor process values, acknowledge alarms, and adjust setpoints. Its compact form factor and panel-flush mounting make it appropriate for integration into control cabinets and machine panels with limited space.

    Technical Specifications

    Display Type LCD text display
    Display Lines 4 lines
    Characters per Line 20 characters
    Keyboard Membrane keypad with function keys and system keys
    Input Voltage 24 V DC
    Communication Interface MPI, PROFIBUS-DP, RS-232/RS-422/RS-485 (point-to-point)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting, flush
    Certifications CE, UL
    Configuration Software ProTool

    Common Error Codes & System Events

    System Error 1
    Communication error between OP17 and connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check communication cable connections and termination resistors. Verify MPI or PROFIBUS address settings on both the OP17 and the PLC. Ensure baud rate settings match on all network nodes.
    System Error 2
    Project data error or missing configuration. The panel has detected corrupted or absent project data in memory.
    Re-download the project from ProTool to the OP17. Check the transfer cable and connection during download. If the error persists, perform a memory reset and re-transfer the project.
    System Error 6
    Internal memory error detected on the operator panel.
    Perform a complete memory reset via the panel's system menu. Re-download the project configuration. If the fault recurs, the internal memory may be faulty and the unit should be repaired or replaced.
    System Error 10
    Timeout error during communication with the PLC. The OP17 did not receive a response from the controller within the expected time window.
    Check network cabling for breaks or poor connections. Verify PLC is in RUN mode and responding on the network. Reduce network load or increase the communication timeout setting in the project configuration.
    System Error 14
    Tag or variable address not found in the PLC. The OP17 is attempting to access a data address that does not exist or is out of range in the connected controller.
    Review the project configuration in ProTool and verify all variable addresses match the actual PLC data block and memory addresses. Correct any mismatched addresses and re-download the project.
    System Error 20
    Transfer mode active. The panel is waiting for a project download and normal operation is suspended.
    Initiate a project transfer from ProTool on the connected PC, or exit transfer mode via the panel keypad if no download is intended. Ensure the correct COM port and transfer settings are selected in ProTool.
    System Error 40
    Operating system error or firmware fault detected on the OP17.
    Cycle power to the panel. If the error persists, update or re-flash the panel firmware using the appropriate Siemens tool. Contact Siemens technical support if the fault cannot be cleared.

    Frequently Asked Questions

    Which PLCs are compatible with the Siemens OP17 (6AV3617-1JC20-0AX1)?

    The OP17 is compatible with Siemens SIMATIC S7-200, S7-300, S7-400, and S5 series PLCs via MPI or PROFIBUS-DP interfaces. Point-to-point serial connections also allow integration with third-party controllers supported by ProTool drivers.

    What software is used to configure and program the OP17?

    The OP17 is configured using Siemens ProTool software. Projects are created on a PC and transferred to the panel via a serial cable connection.

    What is the supply voltage for the 6AV3617-1JC20-0AX1?

    The OP17 operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range for reliable operation.

    What is the front panel protection rating of the OP17?

    The front face of the OP17 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel mounting environments.

    Can the OP17 display graphics or only text?

    The OP17 is a text-based operator panel and does not support graphical display. It shows alphanumeric characters across 4 lines of 20 characters each.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector on the rear of the panel. Verify the supply is within tolerance and the connector is fully seated. Inspect for any visible damage to the unit.

    Restore correct 24 V DC supply voltage. If the supply is confirmed correct and the display remains blank, the internal power supply or display module may be faulty and the unit should be sent for repair or replacement.

    OP17 shows continuous communication error with PLC

    Verify the MPI or PROFIBUS-DP cable is correctly connected and terminated at both ends. Check that the OP17 node address does not conflict with other devices on the network. Confirm the PLC is powered and in RUN or STOP mode.

    Replace or reseat the communication cable. Correct any duplicate node addresses in the network configuration. Ensure termination resistors are installed only at the physical ends of the bus. Re-download the project if communication parameters have changed.

    Project download from ProTool fails or times out

    Check the serial transfer cable connection between the PC and the OP17. Verify the correct COM port is selected in ProTool and that the baud rate matches the panel settings. Confirm the OP17 is in transfer mode.

    Use a known-good Siemens transfer cable. Set the OP17 to transfer mode via the system menu before initiating the download. Try a lower baud rate if transfer errors persist. Ensure no other application is using the selected COM port on the PC.

    Operator keypad keys not responding or intermittently responding

    Inspect the membrane keypad surface for physical damage, contamination, or wear. Check for any debris beneath the keypad overlay. Test multiple keys to determine if the fault is isolated to specific keys or affects the entire keypad.

    Clean the keypad surface with a dry cloth. If specific keys are permanently unresponsive due to membrane wear or damage, the keypad membrane assembly should be replaced. For units with widespread key failure, internal PCB inspection may be required.

    Alarm messages not displaying correctly or not updating

    Verify that the alarm tag addresses in the ProTool project match the actual PLC memory addresses. Check that the PLC program is correctly writing alarm bit states. Confirm communication between the OP17 and PLC is stable.

    Correct any mismatched alarm variable addresses in the ProTool project and re-download. Ensure the PLC program logic correctly sets and resets alarm bits. If communication is intermittent, resolve network issues first before re-testing alarm display functionality.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart