• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV3617-1JC00-0AX1 OP17
    Siemens 6AV3617-1JC00-0AX1 OP17

    Siemens 6AV3617-1JC00-0AX1 OP17

    € 662,00 – € 799,00Price range: € 662,00 through € 799,00

    Reset
    Clear
    SKU: 6AV3617-1JC00-0AX1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens OP17 (part number 6AV3617-1JC00-0AX1) is a compact operator panel belonging to the SIMATIC HMI family. It is designed for machine-level human-machine interface applications, providing operators with a text-based display and keypad input for monitoring and controlling industrial processes. The OP17 is a member of the OP series of operator panels, which are widely used in conjunction with Siemens SIMATIC PLCs.

    The 6AV3617-1JC00-0AX1 features a 4-line LCD text display capable of showing up to 20 characters per line, allowing clear presentation of process values, messages, and status information. It is equipped with a membrane keypad including function keys, system keys, and numeric input keys for direct operator interaction. The panel communicates via the MPI (Multi-Point Interface) and PROFIBUS DP protocols, enabling seamless integration with S7-200, S7-300, and S7-400 PLCs. Configuration is performed using Siemens ProTool software, and the unit operates on a 24 V DC supply.

    The OP17 is commonly deployed in manufacturing, packaging, material handling, and process automation environments where a cost-effective, robust text-based HMI is required. Its compact form factor and panel-mount design make it suitable for integration into control cabinets and machine panels with limited space. The unit is well-suited for applications requiring straightforward process visualization, alarm management, and parameter input without the need for graphical display capabilities.

    Technical Specifications

    Display Type LCD text display
    Display Lines 4 lines
    Characters per Line 20 characters
    Input/Operating Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Mounting Panel mount
    Configuration Software Siemens ProTool
    PLC Compatibility SIMATIC S7-200, S7-300, S7-400
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 40000
    Communication error between the OP17 and the connected PLC. The panel cannot establish or maintain a connection to the controller.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address and baud rate settings match the OP17 configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 40001
    Timeout error on the MPI or PROFIBUS DP bus. The OP17 has lost communication with the PLC within the configured timeout period.
    Inspect bus cabling for breaks or poor connections. Verify bus termination at both ends of the network. Check for address conflicts on the bus.
    Event ID: 10000
    Configuration data error. The project data stored in the OP17 is corrupted or incompatible with the current firmware version.
    Re-download the project configuration from ProTool to the OP17. Ensure the ProTool project version is compatible with the panel firmware.
    Event ID: 10001
    No project loaded. The OP17 has started without a valid configuration project in memory.
    Transfer a valid ProTool project to the OP17 via the MPI interface or serial download cable.
    Event ID: 20000
    Operating voltage out of range. The 24 V DC supply voltage has dropped below or exceeded the permissible limits.
    Measure the supply voltage at the OP17 power connector. Ensure the power supply provides a stable 24 V DC within the specified tolerance range.
    Event ID: 30000
    Internal memory error. A fault has been detected in the panel's internal RAM or flash memory.
    Perform a factory reset of the OP17 and re-download the project. If the error persists, the panel may require repair or replacement of internal memory components.
    Event ID: 50000
    Tag update error. One or more process tags cannot be read from or written to the connected PLC.
    Verify that the PLC data block addresses referenced in the ProTool project exist and are accessible. Check PLC program for correct data block definitions.

    Frequently Asked Questions

    What communication protocols does the OP17 (6AV3617-1JC00-0AX1) support?

    The OP17 supports MPI (Multi-Point Interface) and PROFIBUS DP for communication with Siemens SIMATIC PLCs including the S7-200, S7-300, and S7-400 series.

    What software is used to configure the Siemens OP17?

    The OP17 is configured using Siemens ProTool configuration software. The project is then downloaded to the panel via the MPI interface or a serial download cable.

    What is the supply voltage for the 6AV3617-1JC00-0AX1?

    The OP17 operates on a 24 V DC supply voltage.

    What is the front panel protection rating of the OP17?

    The OP17 has an IP65 protection rating on the front panel, making it resistant to dust and water jets, suitable for installation in control cabinet doors exposed to industrial environments.

    Can the OP17 display graphical content?

    No, the OP17 is a text-based operator panel with a 4-line by 20-character LCD display. It does not support graphical or bitmap image display; it is intended for alphanumeric text and status messages only.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the internal fuse if accessible. Inspect the display contrast setting, which may have been set to minimum.

    Ensure the power supply is providing stable 24 V DC. Adjust the display contrast using the contrast control keys during startup. If the display remains blank with correct voltage, the panel may require internal repair or display replacement.

    OP17 shows persistent communication error and cannot connect to PLC

    Verify MPI or PROFIBUS DP cable integrity and connector seating. Check that the bus termination resistors are correctly installed at both ends of the network. Confirm the PLC address and baud rate in the ProTool project match the physical PLC settings.

    Replace or re-seat the communication cable. Correct address and baud rate settings in the ProTool project and re-download. Enable bus termination on the OP17 if it is at the end of the bus segment.

    Keypad buttons are unresponsive or intermittently fail

    Inspect the membrane keypad for physical damage, contamination, or wear. Test individual keys to identify whether the fault is isolated to specific keys or affects the entire keypad.

    Clean the keypad surface with a dry cloth. If individual keys are mechanically damaged or the membrane is worn through, the keypad membrane assembly will need to be replaced as a spare part.

    Project download from ProTool fails or is interrupted

    Check the serial or MPI download cable connection between the PC and the OP17. Verify that the correct COM port and transfer settings are selected in ProTool. Ensure the OP17 is in transfer mode before initiating the download.

    Replace the download cable if damaged. Set the OP17 to transfer mode by navigating to the system menu. Confirm ProTool communication settings match the panel interface and retry the download.

    Alarm messages are not displayed on the OP17

    Verify that alarm tags in the ProTool project are correctly mapped to the corresponding PLC data addresses. Check that the PLC program is writing the correct bit values to trigger alarms.

    Review and correct the alarm tag configuration in ProTool, ensuring data block addresses and bit offsets match the PLC program. Re-download the updated project to the OP17 and test alarm triggering from the PLC.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart