• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • Drive
    • 6SE7031-2EP85-0AA0 SIMOVERT MASTERDRIVES
    Awaiting product image

    6SE7031-2EP85-0AA0 SIMOVERT MASTERDRIVES

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6SE7031-2EP85-0AA0 Category: Drive
    • Description
    • Additional information

    The Siemens SIMOVERT MASTERDRIVES 6SE7031-2EP85-0AA0 is a vector control AC drive unit belonging to the SIMOVERT MASTERDRIVES MC (Motion Control) and VC (Vector Control) series. This unit is designed for demanding variable-speed drive applications requiring precise speed and torque control of three-phase induction and synchronous motors. The 6SE7031-2EP85-0AA0 is a compact inverter unit intended for cabinet or panel mounting in industrial environments.

    The 6SE7031-2EP85-0AA0 operates on a three-phase 380–480 V AC supply and delivers a continuous output current of 90 A, corresponding to a power rating of approximately 45 kW. It supports multiple control modes including sensorless vector control and closed-loop field-oriented control with encoder feedback. The unit features a CUVC or compatible control board with serial communication interfaces including USS protocol over RS-485, and optionally PROFIBUS-DP via plug-in communication boards. Parameterization and diagnostics are accessible via the PMU operator panel or an external PC tool (DriveMonitor/STARTER). The drive incorporates integrated DC bus connection capability, enabling energy exchange between multiple drive units in a common DC bus configuration.

    The SIMOVERT MASTERDRIVES series is widely deployed in machine tools, rolling mills, paper and printing machinery, textile production lines, cranes and hoists, and conveyor systems. The 6SE7031-2EP85-0AA0 is particularly suited to applications demanding high dynamic response, precise torque control, and coordinated multi-axis operation. Its modular architecture and common DC bus support make it a practical choice for multi-drive installations where regenerative energy recovery and coordinated motion are required.

    Technical Specifications

    Input Voltage 380–480 V AC (3-phase)
    Output Current (Continuous) 90 A
    Power Rating 45 kW
    Control Type Vector Control (sensorless and closed-loop field-oriented)
    DC Bus Voltage 510–650 V DC
    Switching Frequency 2.5–16 kHz (adjustable)
    Communication Interface USS (RS-485); PROFIBUS-DP (optional via plug-in board)
    Feedback Interface Incremental encoder (HTL/TTL) via optional encoder board
    Operating Temperature 0 °C to +40 °C (derated up to +50 °C)
    Storage Temperature -25 °C to +70 °C
    Relative Humidity ≤ 95 % (non-condensing)
    IP/Protection Rating IP20
    Mounting Cabinet/panel mounting
    Series/Product Family SIMOVERT MASTERDRIVES
    Certifications CE, UL

    Common Fault Codes

    F001
    Overcurrent: Output current has exceeded the permissible limit, typically caused by a short circuit, motor fault, or excessively fast acceleration ramp.
    Check motor wiring for short circuits, verify motor data parameters, and extend the acceleration ramp time (P462/P464). Inspect output IGBTs.
    F002
    Overvoltage: DC bus voltage has exceeded the maximum permissible level, often due to regenerative energy during deceleration.
    Extend the deceleration ramp time (P464), check the braking resistor or chopper module, and verify supply voltage levels.
    F003
    Undervoltage: DC bus voltage has dropped below the minimum threshold, indicating a supply voltage dip or phase loss.
    Check the incoming supply voltage and all three input phases. Verify line fuses and input contactor operation.
    F004
    Drive Overtemperature: The heatsink or internal temperature has exceeded the permissible limit.
    Check cooling fan operation, clean heatsink fins, verify ambient temperature is within specification, and check that ventilation clearances are maintained.
    F008
    Motor Overtemperature: The motor thermal model or PTC/KTY sensor has detected excessive motor temperature.
    Check motor load conditions, verify motor cooling, and check PTC/KTY sensor wiring and parameter settings (P381/P382).
    F011
    Line Phase Failure: One or more input supply phases are missing or have an unacceptable voltage imbalance.
    Check all three input supply phases, line fuses, and input contactor contacts. Measure phase-to-phase voltages at the drive input terminals.
    F015
    Motor Phase Failure: An open circuit has been detected in one of the motor output phases.
    Check motor cable connections at the drive output terminals and at the motor terminal box. Verify motor winding continuity with a multimeter.
    F025
    EEPROM/Parameter Fault: A checksum error or data corruption has been detected in the parameter memory.
    Perform a factory reset (P970 = 1) and re-enter all drive parameters. If the fault persists, the control board (CUVC) may require replacement.

    Frequently Asked Questions

    What is the continuous output current and power rating of the 6SE7031-2EP85-0AA0?

    The 6SE7031-2EP85-0AA0 provides a continuous output current of 90 A, corresponding to a motor power rating of approximately 45 kW at 380–480 V AC.

    What communication protocols does the SIMOVERT MASTERDRIVES 6SE7031-2EP85-0AA0 support?

    The unit natively supports the USS protocol over RS-485. PROFIBUS-DP communication can be added by installing an optional CBP2 plug-in communication board into the control board slot.

    Can this drive be connected to a common DC bus with other SIMOVERT MASTERDRIVES units?

    Yes, the 6SE7031-2EP85-0AA0 supports common DC bus operation, allowing multiple inverter units to share a DC bus supplied by a central rectifier or infeed unit, enabling energy exchange between drives.

    What encoder types are supported for closed-loop vector control?

    The drive supports incremental encoders with HTL and TTL signal levels via an optional encoder evaluation board (e.g., SBP or equivalent) installed on the control board.

    Which parameterization tools are compatible with this drive?

    The drive can be parameterized using the integrated PMU operator panel, or via a PC running Siemens DriveMonitor or STARTER software connected through the serial interface.

    Troubleshooting

    Drive displays F001 overcurrent fault immediately on start

    Check for short circuits in the motor cable or motor windings using an insulation resistance tester. Verify that motor nameplate data has been correctly entered into the drive parameters.

    Repair or replace faulty motor cable or motor. Correct motor data parameters (P100–P115). If the fault persists with no motor connected, the output IGBT module may be damaged and require replacement.

    Drive powers up but display shows no output and the motor does not run

    Check that the enable signal (terminal 28 or equivalent) and the run command are correctly applied. Verify that no fault or alarm is active and that the drive is in the correct operating mode.

    Apply the correct enable and setpoint signals per the wiring diagram. Clear any active faults by cycling power or issuing a fault reset command. Confirm parameter P100 (control mode) and P554 (source of enable) are set correctly.

    Heatsink overtemperature fault (F004) occurs under normal load conditions

    Inspect the cooling fan for operation and airflow obstruction. Measure ambient temperature inside the cabinet. Check that the heatsink fins are not clogged with dust or debris.

    Clean the heatsink fins and replace the cooling fan if it is not running. Ensure cabinet ventilation is adequate and ambient temperature does not exceed 40 °C. Derate the drive if operating above 40 °C.

    PROFIBUS communication loss between drive and PLC

    Check the PROFIBUS cable connections at the CBP2 board and at the PLC. Verify bus termination resistors are correctly installed at both ends of the PROFIBUS segment. Check the drive's PROFIBUS address parameter.

    Reseat the CBP2 communication board. Correct the PROFIBUS node address (P918) to match the PLC configuration. Ensure proper bus termination and cable shielding. Replace the CBP2 board if the fault persists.

    Drive trips on F002 overvoltage during deceleration

    The DC bus voltage is rising above the trip threshold during motor deceleration, indicating insufficient braking capacity. Check whether a braking chopper and resistor are installed and functioning.

    Extend the deceleration ramp time in parameter P464. If fast deceleration is required, install or verify the operation of a braking chopper module and correctly sized braking resistor. Check braking resistor connections and resistance value.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Lenze EPM-T831 EPM-T831

      € 128,00
      Read more
    • Placeholder

      Lenze E94AZPS0074N Lenze 9400 HighLine

      € 129,00
      Read more
    • Placeholder

      Lenze E94AZPM0324 Lenze 9400 HighLine

      € 130,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart