• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • PLC
    • 6ES7951-0KF00-0AA0 SIMATIC S7 Memory Card
    Awaiting product image

    6ES7951-0KF00-0AA0 SIMATIC S7 Memory Card

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6ES7951-0KF00-0AA0 Category: PLC
    • Description
    • Additional information

    The Siemens SIMATIC S7 6ES7951-0KF00-0AA0 is a Flash EPROM memory card designed for use with SIMATIC S7-300 programmable logic controllers. It belongs to the SIMATIC S7 memory card family and serves as a load memory module, storing the user program, data blocks, and configuration data for the CPU. The card plugs directly into the designated memory card slot on compatible S7-300 CPU modules.

    The 6ES7951-0KF00-0AA0 is a 64 KB Flash EPROM card, providing non-volatile storage that retains data without a backup battery. The card supports the standard SIMATIC S7 memory card interface and is compatible with a range of S7-300 CPUs that accept this card form factor. Data written to the card is retained even when power is removed, making it suitable for reliable program storage in industrial environments.

    This memory card is widely used in manufacturing automation, process control, and machine tool applications where S7-300 PLCs are deployed. It is particularly suited for applications requiring reliable, battery-free program retention, such as conveyor systems, packaging machinery, and process plant control panels. The card also facilitates easy program transfer and CPU replacement in the field without requiring a programming device.

    Technical Specifications

    Memory Type Flash EPROM
    Memory Capacity 64 KB
    Series/Product Family SIMATIC S7-300
    Interface SIMATIC S7 memory card slot
    Data Retention Non-volatile (no backup battery required)
    Operating Temperature 0 °C to +60 °C
    Storage Temperature -40 °C to +85 °C
    Mounting Direct plug-in to CPU memory card slot
    Certifications CE, UL
    Form Factor SIMATIC S7 memory card (plug-in module)

    Common Diagnostic Codes

    Fault Code 1
    Memory card not recognized by CPU
    Remove and re-insert the memory card. Verify the card is fully seated in the slot. Check for physical damage to the card contacts.
    Fault Code 2
    Memory card write error during program download
    Ensure the memory card is not write-protected. Try erasing the card using STEP 7 before re-downloading the program.
    Fault Code 3
    Program on memory card incompatible with CPU type
    Verify the program was compiled for the correct CPU type and firmware version. Re-download the correct program using STEP 7.
    Fault Code 4
    Memory card capacity exceeded
    Check the size of the user program and data blocks. Reduce program size or use a higher-capacity memory card.
    Fault Code 5
    Memory card read error during CPU startup
    Replace the memory card. If the error persists, check the CPU memory card slot for damage or contamination.
    Fault Code 6
    Memory card erase failure
    Attempt the erase operation again using STEP 7. If the card cannot be erased, it may be faulty and should be replaced.

    Frequently Asked Questions

    Which S7-300 CPUs are compatible with the 6ES7951-0KF00-0AA0 memory card?

    The 6ES7951-0KF00-0AA0 is compatible with S7-300 CPUs that accept the standard SIMATIC S7 Flash EPROM memory card format. Refer to the specific CPU manual to confirm memory card compatibility before installation.

    Does the 6ES7951-0KF00-0AA0 require a backup battery to retain data?

    No, this Flash EPROM memory card retains data without a backup battery. Data is stored non-volatilely and is preserved even when power is removed from the system.

    Can the 6ES7951-0KF00-0AA0 be erased and reprogrammed?

    Yes, the card can be erased and reprogrammed using the STEP 7 programming software. The erase and write operations are performed via the CPU with the card inserted in the memory card slot.

    What is the storage capacity of the 6ES7951-0KF00-0AA0?

    The 6ES7951-0KF00-0AA0 provides 64 KB of Flash EPROM storage for user programs, data blocks, and configuration data.

    Can this memory card be used to transfer programs between CPUs?

    Yes, the memory card can be used to transfer programs from one S7-300 CPU to another compatible CPU, enabling field replacement and program deployment without a programming device.

    Troubleshooting

    CPU does not recognize the memory card after insertion

    Check that the card is fully and correctly seated in the memory card slot. Inspect the card edge contacts for contamination or physical damage.

    Clean the card contacts with isopropyl alcohol and re-insert the card firmly. If the CPU still does not recognize the card, test with a known-good card to determine whether the fault lies with the card or the CPU slot.

    Program download to memory card fails in STEP 7

    Verify the card is not write-protected and that the correct CPU is online. Check available card capacity against the program size.

    Erase the memory card using the STEP 7 'Delete' function before attempting a new download. Ensure the program size does not exceed 64 KB.

    CPU enters STOP mode immediately after startup with memory card inserted

    The program stored on the memory card may be incompatible with the CPU firmware version, or the card data may be corrupted.

    Erase the memory card and re-download the correct program using STEP 7. Verify the program is compiled for the correct CPU type and firmware version.

    Memory card cannot be erased using STEP 7

    The card may have reached its write/erase cycle limit or may be physically damaged. Check STEP 7 diagnostics for specific error messages during the erase operation.

    Replace the memory card with a new 6ES7951-0KF00-0AA0 or equivalent. Flash EPROM cards have a finite number of erase cycles and may need replacement after extended use.

    Data on memory card is lost after power cycle

    Flash EPROM cards should retain data without power. If data is lost, the card may be faulty or the write operation during download may not have completed successfully.

    Re-download the program to the card and confirm successful completion in STEP 7. If data loss persists, replace the memory card.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Sold out

      Siemens Simatic 6GK5208-0BA10-2AA3

      Read more
    • Placeholder

      Siemens Simatic S7 6ES7331-7PF00-0AB0

      € 407,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens Simatic ET200 6ES7132-0BH11-0XB0

      € 478,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart