• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • PLC
    • 6ES7350-2AH00-0AE0 SIMATIC S7-300 FM 350-2
    Awaiting product image

    6ES7350-2AH00-0AE0 SIMATIC S7-300 FM 350-2

    Reset

    This product is currently out of stock and unavailable.

    SKU: 6ES7350-2AH00-0AE0 Category: PLC
    • Description
    • Additional information

    The Siemens SIMATIC S7-300 FM 350-2 (part number 6ES7350-2AH00-0AE0) is a high-speed counter and positioning function module designed for use within the S7-300 programmable logic controller family. It belongs to the FM 350 series of intelligent function modules and is capable of processing encoder signals and performing counting, measuring, and positioning tasks independently of the CPU cycle time. The module offloads time-critical counting and positioning operations from the main CPU, enabling faster and more deterministic response to encoder inputs.

    The FM 350-2 supports eight independent counter channels, each capable of operating in counting, frequency measurement, or period measurement mode. It accepts 24 V DC incremental encoder signals and provides digital outputs that can be used for direct control of actuators based on counter comparator values. The module communicates with the S7-300 CPU via the internal S7-300 backplane bus and is configured and programmed using the STEP 7 software environment with the dedicated FM 350-2 configuration tool. It supports up to 500 kHz counting frequency per channel and provides hardware-based comparator outputs for real-time response.

    The FM 350-2 is widely used in packaging machinery, conveyor systems, printing presses, and material handling equipment where multiple high-speed counting or positioning tasks must be performed simultaneously. Its ability to handle eight channels independently makes it suitable for applications requiring synchronization of multiple axes or monitoring of several encoder-equipped drives at once. Industries such as automotive manufacturing, food and beverage processing, and logistics rely on this module for precise position detection and speed measurement tasks.

    Technical Specifications

    Number of Counter Channels 8
    Maximum Counting Frequency 500 kHz
    Encoder Input Voltage 24 V DC
    Encoder Signal Type 24 V DC incremental encoder (single or dual channel)
    Digital Outputs 8 (24 V DC, comparator outputs)
    Digital Inputs 8 (24 V DC, gate/latch/reset functions)
    Counter Resolution 32-bit
    Operating Modes Counting, frequency measurement, period measurement
    Bus Interface S7-300 backplane bus
    Supply Voltage 24 V DC (via backplane and front connector)
    Operating Temperature 0 °C to +60 °C
    Storage Temperature -40 °C to +70 °C
    Relative Humidity 10 % to 95 % (non-condensing)
    Dimensions (W x H x D) 40 mm x 125 mm x 120 mm
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC S7-300 FM 350

    Common Diagnostic Codes

    Fault Code 1
    Configuration error: The module configuration stored in the CPU does not match the actual module inserted in the slot.
    Re-configure the module in STEP 7 and perform a new download to the CPU. Verify the correct module is installed in the correct slot.
    Fault Code 2
    Front connector not plugged in or missing 24 V DC supply voltage at the front connector.
    Check that the front connector is properly seated and that 24 V DC is present on the supply terminals. Measure voltage at the front connector supply pins.
    Fault Code 3
    Encoder wire break or short circuit detected on one or more counter channels.
    Inspect encoder wiring for open circuits or short circuits. Verify encoder supply voltage and signal levels at the front connector terminals.
    Fault Code 4
    Counter overflow or underflow: The 32-bit counter value has exceeded its upper or lower limit.
    Review the application program to ensure counter limits and gate control are configured correctly. Adjust comparator values or enable ring counter mode if appropriate.
    Fault Code 5
    Hardware interrupt lost: A hardware interrupt triggered by a comparator event was not processed in time by the CPU.
    Reduce CPU load or increase the priority of the hardware interrupt OB (OB40). Check that the interrupt OB is present in the user program.
    Fault Code 6
    Module not ready or internal module fault detected during self-test at startup.
    Power cycle the S7-300 rack. If the fault persists, reseat the module in the rack. If the fault continues, the module may require replacement or repair.
    Fault Code 7
    Parameter assignment error: Invalid or out-of-range parameters were transferred to the module during startup.
    Review the FM 350-2 parameter settings in the STEP 7 configuration tool. Correct any invalid values and re-download the configuration to the CPU.

    Frequently Asked Questions

    How many counter channels does the FM 350-2 provide?

    The FM 350-2 provides 8 independent counter channels, each configurable for counting, frequency measurement, or period measurement mode.

    What type of encoder signals does the 6ES7350-2AH00-0AE0 accept?

    The module accepts 24 V DC incremental encoder signals. Each channel supports single-channel or dual-channel (A/B) encoder inputs with optional gate, latch, and reset inputs.

    What software is required to configure the FM 350-2?

    The module is configured using Siemens STEP 7 (version 5.x) with the dedicated FM 350-2 parameter assignment tool, which is included in the STEP 7 software package or available as a separate installation.

    Can the FM 350-2 operate independently of the S7-300 CPU cycle?

    Yes, the FM 350-2 processes encoder signals and controls its digital outputs independently of the CPU scan cycle, enabling deterministic real-time response to high-speed counting events without CPU intervention.

    What is the maximum counting frequency supported per channel?

    Each of the 8 channels supports a maximum counting frequency of 500 kHz, allowing accurate measurement of high-speed encoder signals.

    Troubleshooting

    SF (System Fault) LED on the FM 350-2 is lit after power-on

    Check the CPU diagnostic buffer in STEP 7 for module-related fault entries. Verify that the module configuration in HW Config matches the physical module and slot position.

    Re-download the hardware configuration from STEP 7 to the CPU. If the SF LED remains on, check the front connector wiring and 24 V DC supply. Replace the module if an internal hardware fault is confirmed.

    Counter values are not incrementing despite encoder movement

    Measure the encoder output signals at the front connector terminals using an oscilloscope or multimeter. Verify that the encoder supply voltage (24 V DC) is present and that the gate input is in the enabled state.

    Correct any wiring faults on the encoder signal lines. Ensure the gate input is not held in the disabled state by the application program. Verify encoder signal polarity and wiring against the FM 350-2 manual.

    Digital outputs do not switch at the expected comparator values

    Check the comparator values configured in the FM 350-2 parameter assignment tool and verify they are within the valid counter range. Confirm that the output enable parameter is set correctly in the module configuration.

    Correct the comparator threshold values in STEP 7 and re-download the configuration. Verify that the output wiring is correct and that the load connected to the output does not exceed the rated output current.

    Hardware interrupt OB (OB40) is not being called when a comparator event occurs

    Verify that OB40 is present in the STEP 7 project and has been downloaded to the CPU. Check the FM 350-2 configuration to confirm that hardware interrupt generation is enabled for the relevant channel.

    Add OB40 to the STEP 7 project if it is missing and re-download the program. Enable hardware interrupt output in the FM 350-2 parameter settings and ensure the CPU operating mode supports interrupt processing.

    Module is not recognized by the CPU after installation

    Check that the module is firmly seated in the S7-300 rack and that the rack bus connector is properly engaged. Verify the slot assignment in the STEP 7 HW Config matches the physical slot used.

    Reseat the module and bus connector. Update the HW Config in STEP 7 to reflect the correct slot and re-download. If the module is still not recognized, test the module in a different rack slot or test the rack bus connector for damage.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens Simatic S7 6ES7431-0HH00-0AB0

      € 359,00 – € 484,00Price range: € 359,00 through € 484,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens Simatic S7 6ES7331-7PF00-0AB0

      € 407,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6ES5955-3LF12 SIMATIC S5 955

      € 69,00 – € 624,00Price range: € 69,00 through € 624,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart