Siemens 6ES7626-1AG02-0AE3 SIMATIC C7-626
€ 1.899,00
The Siemens SIMATIC C7-626, part number 6ES7626-1AG02-0AE3, is a compact combined controller and operator panel unit belonging to the SIMATIC C7 product family. It integrates a SIMATIC S7-300 compatible CPU with an operator panel into a single housing, eliminating the need for separate PLC and HMI components. This all-in-one design is intended for space-constrained control cabinet installations where both control logic and local operator interaction are required.
The C7-626 features a built-in monochrome STN LCD display with touch or membrane key operation, and incorporates an integrated S7-300 CPU with onboard digital I/O. It supports MPI (Multi-Point Interface) communication for integration into SIMATIC networks and can be programmed using STEP 7 software for the PLC portion and ProTool or WinCC flexible for the HMI configuration. The unit includes integrated flash memory for program and data storage, and supports expansion via standard S7-300 I/O modules through the integrated backplane bus interface.
The SIMATIC C7-626 is commonly deployed in machine-level automation tasks across manufacturing, packaging, and process industries where a compact footprint is essential. It is well suited for standalone machine control panels, small to medium automation cells, and retrofit applications where combining the HMI and PLC into one unit reduces wiring complexity and cabinet space. Its compatibility with the S7-300 ecosystem makes it straightforward to integrate into existing SIMATIC installations.
Technical Specifications
| Series/Product Family | SIMATIC C7 |
|---|---|
| Display Type | Monochrome STN LCD |
| Communication Interface | MPI (Multi-Point Interface) |
| Integrated CPU | S7-300 compatible CPU |
| Onboard Digital Inputs | 16 |
| Onboard Digital Outputs | 16 |
| Input/Operating Voltage | 24 V DC |
| Operating Temperature | 0 °C to +55 °C |
| Storage Temperature | -20 °C to +70 °C |
| Relative Humidity | 10 % to 90 % (non-condensing) |
| IP Rating (Front) | IP65 |
| Programming Software | STEP 7 / ProTool / WinCC flexible |
| Mounting | Panel mounting |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 10000
- MPI communication fault detected between C7 unit and connected devices on the MPI network.
Check MPI cable connections and termination resistors. Verify MPI address settings are unique and correct. Restart the C7 unit and connected devices. - Event ID: 10001
- Configuration error: the loaded HMI project does not match the connected PLC program or tag configuration.
Re-download the HMI project using ProTool or WinCC flexible ensuring tag names and addresses match the STEP 7 program. Verify the correct project version is loaded. - Event ID: 10002
- Tag update timeout: a configured tag could not be updated within the defined cycle time.
Check MPI network load and reduce the number of tags or increase the update cycle time in the HMI project configuration. - Event ID: 10003
- Operating system error or internal CPU exception detected.
Perform a memory reset (MRES) on the CPU. Reload the STEP 7 program and HMI project. If the fault persists, the unit may require repair or replacement. - Event ID: 10004
- Battery low or backup battery failure. Retentive data and real-time clock may be lost on power cycle.
Replace the internal backup battery with the correct Siemens replacement type. After replacement, reload retentive data and reset the real-time clock. - Event ID: 10005
- I/O access error: the CPU cannot access configured onboard or expansion I/O modules.
Check wiring to onboard I/O terminals and verify that any connected S7-300 expansion modules are correctly seated and addressed. Review the hardware configuration in STEP 7. - Event ID: 10006
- STOP mode: CPU has transitioned to STOP state due to a programming error or hardware fault.
Connect STEP 7 programming software via MPI, read the diagnostic buffer to identify the cause, correct the program error or hardware fault, and restart the CPU.
Frequently Asked Questions
What programming software is required for the SIMATIC C7-626?
The PLC portion is programmed using Siemens STEP 7, while the HMI portion is configured using ProTool or WinCC flexible. Both software packages must be used together to fully configure the C7-626.
Is the C7-626 compatible with S7-300 expansion I/O modules?
Yes, the C7-626 integrates an S7-300 compatible CPU and supports expansion with standard S7-300 signal modules via its integrated backplane bus interface.
What communication interfaces does the 6ES7626-1AG02-0AE3 support?
The unit supports MPI (Multi-Point Interface) as its primary communication interface, allowing integration into SIMATIC S7 networks and connection to programming devices.
What is the supply voltage for the C7-626?
The C7-626 operates on a 24 V DC supply voltage, which must be provided externally to the unit.
Can the C7-626 be used as a standalone controller without an external PLC?
Yes, the C7-626 integrates both the CPU and HMI into a single unit, allowing it to function as a standalone controller with onboard I/O and local operator interface without requiring a separate PLC.
Troubleshooting
Display remains blank after power is applied
Measure 24 V DC at the power supply terminals of the C7 unit. Check the internal fuse and verify the power supply is within specification.
Ensure the 24 V DC supply is stable and within the permitted voltage range. Replace the internal fuse if blown. If the display remains blank with correct supply voltage, the display or internal power board may require repair.
CPU remains in STOP mode and will not transition to RUN
Connect STEP 7 via MPI and read the diagnostic buffer to identify the specific fault causing the STOP condition. Check for configuration mismatches between the hardware configuration and the physical modules installed.
Correct any program errors identified in the diagnostic buffer. Ensure the hardware configuration in STEP 7 matches the actual physical setup. Perform a memory reset (MRES) and reload the program if necessary.
HMI tags show no value or display question marks
Verify MPI communication is active between the HMI and CPU portions. Check that the tag addresses in the HMI project correspond to the correct data areas in the STEP 7 program.
Re-download the HMI project using ProTool or WinCC flexible. Confirm tag addresses and data types match the STEP 7 program. Check MPI cable integrity and network termination.
Retentive data is lost after power cycle
Check the status of the internal backup battery. A low or failed battery will cause loss of retentive memory and real-time clock data on power removal.
Replace the internal backup battery with the Siemens-specified replacement. After replacement, reload any required retentive data values and reset the real-time clock via STEP 7 or the HMI.
MPI communication errors or inability to connect programming device
Check MPI cable connections, verify correct MPI address assignment on the C7 unit, and confirm that bus termination resistors are correctly placed at both ends of the MPI segment.
Set a unique MPI address on the C7 unit, ensure termination is active only at the physical ends of the bus, and use a known-good MPI cable. Reduce the MPI bus length or number of nodes if communication remains unstable.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page