Siemens 6AV6642-6EA10-0UH0 MP 177
€ 686,00
The Siemens Multi Panel MP 177, part number 6AV6642-6EA10-0UH0, is a compact operator panel belonging to the SIMATIC HMI Multi Panel family. It features a 5.7-inch display and is designed for machine-level visualization and operator control in industrial automation environments. This panel is part of Siemens' established HMI portfolio, configured and programmed using WinCC flexible software.
The MP 177 is equipped with a resistive touch screen and function keys, providing flexible operator input options. It supports MPI and PROFIBUS DP communication interfaces for integration with Siemens SIMATIC S7 PLCs, as well as serial interfaces for third-party controller connectivity. The panel operates on 24 V DC supply voltage and is built to withstand industrial conditions, with a front panel protection rating of IP65. It includes onboard flash memory for project storage and supports external memory cards for data logging and recipe management.
The MP 177 is widely deployed in machine building, packaging machinery, printing equipment, and general factory automation applications. Its compact form factor and dual input method — touch and keys — make it suitable for environments where operators require both graphical visualization and tactile key input. The panel's compatibility with the SIMATIC S7 controller family makes it a common choice for OEMs building machines around Siemens automation platforms.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Colors | 256 colors (STN) |
| Touch Technology | Resistive touch screen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 9 W |
| Communication Interface | MPI, PROFIBUS DP, RS-422/485, USB |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC HMI Multi Panel |
| Configuration Software | WinCC flexible 2008 or later |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between HMI panel and PLC. Connection to the configured controller cannot be established or has been lost.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode. - Event ID: 10001
- Connection to PLC interrupted during runtime. The panel lost communication with the configured controller.
Inspect the communication cable for damage. Check bus termination and cable shielding. Verify network address conflicts are not present on the MPI or PROFIBUS segment. - Event ID: 20000
- Project download error. Transfer of the HMI project from the engineering PC to the panel failed.
Ensure the panel is set to Transfer mode. Verify the communication settings in WinCC flexible match the physical connection (MPI address, baud rate). Check the USB or MPI cable integrity. - Event ID: 40000
- System memory low. The available memory for runtime operation is insufficient.
Reduce the project size by removing unused screens, graphics, or data logs. Archive and clear data log files stored on the panel. Consider using an external memory card for data storage. - Event ID: 50000
- Recipe data error. A recipe record could not be read or written correctly.
Check the recipe configuration in WinCC flexible for correct data type assignments. Verify the memory card is properly inserted and not write-protected. Re-download the project if recipe configuration has changed. - Event ID: 70000
- Illegal system state detected. The panel runtime encountered an unexpected internal error.
Perform a controlled restart of the HMI panel. If the error persists after restart, re-download the project from WinCC flexible. Check for firmware compatibility between the panel and the project version. - Event ID: 80000
- Firmware update error. A firmware update process was interrupted or failed to complete.
Retry the firmware update using the ProSave tool with the correct firmware version for the MP 177. Ensure stable power supply during the update process. Do not interrupt the update once started.
Frequently Asked Questions
Which communication interfaces does the MP 177 (6AV6642-6EA10-0UH0) support?
The MP 177 supports MPI and PROFIBUS DP for direct connection to Siemens SIMATIC S7 PLCs, as well as RS-422/485 serial interfaces for third-party controllers. A USB interface is also available for project transfer and peripheral devices.
Which software is used to configure and program the MP 177?
The MP 177 is configured using Siemens WinCC flexible 2008 or a compatible version. Projects are downloaded to the panel via USB or MPI connection using the WinCC flexible engineering software or the standalone ProSave utility.
Is the MP 177 compatible with SIMATIC S7-300 and S7-400 PLCs?
Yes, the MP 177 is designed for direct integration with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP. It can also communicate with S7-200 PLCs via the RS-485 serial interface using the appropriate driver.
What is the front panel protection rating of the MP 177?
The front panel of the MP 177 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets. The rear of the unit is rated IP20.
Can the MP 177 store recipes and data logs?
Yes, the MP 177 supports recipe management and data logging functions. Data can be stored in the panel's internal flash memory or on an external memory card inserted into the card slot.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the panel's power connector. Check that the supply is within the specified tolerance. Inspect the panel for any visible damage to the connector or internal components.
Ensure the 24 V DC supply is stable and within tolerance. If the supply is correct and the display remains blank, the internal power supply or backlight may have failed. The unit should be sent for repair or the backlight assembly replaced by a qualified technician.
HMI panel cannot establish communication with the PLC
Verify the MPI or PROFIBUS DP address configured in the HMI project matches the physical PLC address. Check cable connections, bus termination resistors at both ends of the segment, and cable shielding continuity.
Correct any address mismatches in the WinCC flexible project and re-download. Replace damaged communication cables. Ensure only one termination resistor is active at each end of the bus segment. Confirm the PLC is powered and in RUN mode.
Touchscreen does not respond or responds inaccurately
Check whether the touch area is physically damaged or contaminated. Attempt to recalibrate the touchscreen through the panel's Start Center or Control Panel settings. Determine if the issue is limited to specific screen areas.
Clean the touch surface with a soft, dry cloth. Perform a touchscreen recalibration via the panel's system settings. If calibration does not resolve the issue, the resistive touch overlay may be worn or damaged and requires replacement.
Project transfer from PC to panel fails
Confirm the panel is in Transfer mode (accessible from the Start Center). Check the USB or MPI cable connection between the PC and the panel. Verify that the communication parameters in WinCC flexible match the physical interface settings.
Set the panel to Transfer mode before initiating the download. Use a known-good USB or MPI cable. Ensure the correct COM port or MPI address is selected in WinCC flexible. Disable any firewall or antivirus software that may be blocking the transfer on the PC.
Panel repeatedly restarts or crashes during runtime
Check the 24 V DC supply for voltage drops or ripple, which can cause unexpected resets. Review the project for memory overload conditions. Check the panel's operating temperature and ensure adequate ventilation around the unit.
Stabilize the power supply and ensure it is adequately rated for the panel's power consumption. Optimize the project to reduce memory usage. Ensure the panel is installed within the specified operating temperature range of 0 °C to +50 °C and that ventilation slots are not obstructed.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page