Siemens 6AV6642-0AA11-0AX0 TP177A
€ 499,00 – € 796,13Price range: € 499,00 through € 796,13
The Siemens 6AV6642-0AA11-0AX0 is a TP177A series touch panel HMI belonging to the SIMATIC HMI family, designed for machine-level operator control and monitoring. This unit provides a compact and cost-effective human-machine interface solution for integration into automation systems. It is part of the 177 series, which bridges the gap between entry-level and mid-range HMI panels in the Siemens portfolio.
The TP177A features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA) and resistive touch operation. It supports communication via PROFIBUS DP and MPI interfaces, enabling direct connection to Siemens S7-200, S7-300, and S7-400 PLCs. The panel is configured using WinCC flexible 2008 Compact or higher, and operates on a 24 V DC supply. It includes 256 KB of user memory for project data and supports recipe management and alarm logging functions.
The TP177A is widely deployed in manufacturing, packaging, and process automation environments where a reliable and straightforward operator interface is required. It is commonly found on standalone machines, conveyor systems, and small-to-medium automation cells. Its compact form factor and PROFIBUS/MPI connectivity make it particularly suitable for integration into existing Siemens S7-based control architectures.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN color |
| Display Resolution | 320 x 240 pixels (QVGA) |
| Display Colors | 256 colors |
| Touch Technology | Resistive |
| Input Voltage | 24 V DC |
| Power Consumption | 6 W (typical) |
| Communication Interface | PROFIBUS DP, MPI |
| User Memory | 256 KB |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Configuration Software | WinCC flexible 2008 Compact or higher |
Common Error Codes & System Events
- Event ID: 10000
- Configuration error detected during startup; project data could not be loaded correctly.
Re-transfer the project from WinCC flexible to the panel. Verify project compatibility with the firmware version installed on the device. - Event ID: 10001
- Communication connection to the PLC has been interrupted or cannot be established.
Check PROFIBUS/MPI cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. - Event ID: 20000
- System memory is insufficient to load the current project.
Reduce project size by removing unused screens, images, or variables. Ensure project memory does not exceed the 256 KB user memory limit. - Event ID: 40000
- Firmware update error; update process was interrupted or failed.
Repeat the firmware update procedure using ProSave or WinCC flexible. Ensure stable power supply during the update process. - Event ID: 50000
- Tag or variable address in the project is invalid or cannot be resolved.
Open the project in WinCC flexible and verify all variable addresses correspond to valid PLC data areas. Correct any mismatched or undefined tags. - Event ID: 60000
- Recipe data transfer error; data could not be read from or written to the PLC.
Check recipe configuration and ensure the target PLC data block addresses are accessible and correctly defined in the project. - Event ID: 70000
- Alarm buffer overflow; the number of pending alarms exceeds the buffer capacity.
Acknowledge and clear active alarms. Review alarm configuration to reduce simultaneous alarm triggers or increase acknowledgment frequency.
Frequently Asked Questions
Which PLCs are compatible with the TP177A (6AV6642-0AA11-0AX0)?
The TP177A supports communication with Siemens S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It is not natively compatible with S7-1200 or S7-1500 PLCs.
What software is used to configure and program the TP177A?
The TP177A is configured using Siemens WinCC flexible 2008 Compact or higher. Projects are transferred to the panel via MPI cable or USB-to-MPI adapter using the ProSave tool or directly from WinCC flexible.
What is the display resolution and color depth of the TP177A?
The TP177A features a 5.7-inch STN display with a resolution of 320 x 240 pixels (QVGA) and supports 256 colors.
What is the supply voltage required for the TP177A?
The TP177A requires a 24 V DC power supply. Ensure the supply is within the permissible voltage tolerance range as specified in the device manual.
What is the front panel protection rating of the TP177A?
The front panel of the TP177A carries an IP65 protection rating, making it suitable for panel-mounted installations where dust and water ingress protection is required.
Troubleshooting
Display remains blank after power on
Measure 24 V DC at the power supply terminals of the panel. Check that the supply voltage is within the specified tolerance. Inspect the internal fuse if accessible.
Restore correct 24 V DC supply voltage. If the supply is correct and the display remains blank, the backlight or internal power board may be faulty and the unit should be sent for repair or the backlight replaced.
HMI shows 'No connection to PLC' or communication error on startup
Verify the MPI or PROFIBUS DP cable is securely connected at both the HMI and PLC ends. Check bus termination resistors are correctly placed at both ends of the network. Confirm the PLC address in the HMI project matches the actual PLC configuration.
Correct any wiring or termination issues. Update the PLC address in the WinCC flexible project if mismatched, then re-transfer the project to the panel.
Touchscreen does not respond or responds inaccurately
Attempt to recalibrate the touchscreen via the Control Panel in the panel's Start Center. Check for physical damage or contamination on the touch surface.
Perform a touchscreen recalibration through the device's Start Center menu. Clean the screen surface with a soft cloth. If calibration does not resolve the issue, the resistive touch overlay may need replacement.
Project transfer from WinCC flexible fails
Check the MPI/USB adapter driver installation on the PC. Verify the correct COM port and transfer settings are selected in WinCC flexible. Ensure the panel is in Transfer mode.
Set the panel to Transfer mode via the Start Center. Reinstall or update the PC adapter USB driver. Confirm the correct interface and baud rate settings in WinCC flexible before retrying the transfer.
Panel repeatedly restarts or enters a boot loop
This may indicate a corrupted project file or a firmware mismatch. Attempt to access the Start Center during boot by pressing the touch area when prompted.
Use ProSave to perform a clean firmware update and then re-transfer the project. If the issue persists, perform a factory reset via the Start Center and reload both firmware and project from scratch.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page