Siemens 6AV6641-0AA11-0AX0 TP177A
€ 345,00 – € 699,00Price range: € 345,00 through € 699,00
The Siemens 6AV6641-0AA11-0AX0 is a TP177A touch panel HMI device belonging to the SIMATIC HMI 177 series, manufactured by Siemens. It is a compact operator panel designed for machine-level visualization and control tasks in industrial automation environments. This unit features a 5.7-inch STN color display and is operated via a resistive touch screen interface.
The TP177A supports communication via MPI and PROFIBUS-DP interfaces, enabling direct integration with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs. It is configured using WinCC flexible Compact engineering software. The panel operates on a 24 V DC supply and is rated IP65 on the front face, providing protection against dust and water ingress in demanding industrial environments. Internal memory supports the storage of project data, recipes, and alarm logs.
The TP177A is widely deployed in machine building, packaging machinery, conveyor systems, and general factory automation where a compact and cost-effective HMI solution is required. Its PROFIBUS-DP connectivity makes it suitable for integration into distributed automation architectures. The panel's compact form factor and standard panel cutout dimensions allow straightforward installation into control cabinet doors and operator stations.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN color |
| Display Colors | 256 colors |
| Display Resolution | 320 x 240 px (QVGA) |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| Power Consumption | Max. 6 W |
| Communication Interface | MPI, PROFIBUS-DP (RS-485) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Engineering Software | WinCC flexible Compact |
Common Error Codes & System Events
- Event ID: 10000
- Configuration error detected during startup; project data on the panel may be corrupt or incompatible.
Re-transfer the project from WinCC flexible Compact to the panel. Ensure the software version matches the panel firmware version. - Event ID: 10001
- Communication connection to the PLC has been lost or cannot be established.
Check MPI or PROFIBUS-DP cable connections and termination resistors. Verify PLC address settings and baud rate configuration in the project. - Event ID: 20000
- System memory is low; available memory for runtime operation is insufficient.
Reduce the project size by removing unused screens, tags, or archive data. Transfer the optimized project to the panel. - Event ID: 40000
- Tag update error; a configured tag cannot be read from or written to the connected controller.
Verify the tag address in WinCC flexible matches the actual PLC data block or memory address. Check PLC program for address conflicts. - Event ID: 50000
- Recipe data error; recipe records cannot be read or written correctly.
Check recipe configuration in WinCC flexible. Re-transfer the project and verify available internal memory for recipe storage. - Event ID: 70000
- Operating system or firmware error detected on the panel.
Perform a panel reset using the Start Center. If the fault persists, update the panel firmware using ProSave or WinCC flexible. - Event ID: 110000
- Alarm buffer overflow; the number of pending alarms exceeds the configured buffer size.
Acknowledge and clear active alarms. Increase the alarm buffer size in the WinCC flexible project configuration if required.
Frequently Asked Questions
Which PLCs are compatible with the TP177A (6AV6641-0AA11-0AX0)?
The TP177A is compatible with Siemens SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS-DP communication interfaces. It can also communicate with S7-200 via the PPI protocol.
What software is used to configure and program the TP177A?
The TP177A is configured using Siemens WinCC flexible Compact engineering software. Projects are transferred to the panel via MPI cable or a USB-to-MPI adapter.
What is the supply voltage for the TP177A?
The TP177A requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range to avoid panel faults.
What is the front panel protection rating of the TP177A?
The front face of the TP177A is rated IP65, providing full protection against dust ingress and protection against low-pressure water jets. The rear of the unit is rated IP20.
Can the TP177A display be used with a stylus or gloved hand?
The TP177A uses a resistive touch screen technology, which can be operated with a stylus or a gloved hand, making it suitable for environments where bare finger operation is not practical.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel power connector. Check that the supply is within tolerance and that the connector is fully seated.
Correct any supply voltage issues. If the supply is confirmed good, check the internal fuse on the panel PCB. A blank display with correct supply may indicate a failed backlight or internal power board requiring unit repair or replacement.
Touch screen does not respond or responds inaccurately
Check whether the touch screen is physically damaged or contaminated. Attempt a touch screen recalibration via the panel's Start Center menu.
Clean the touch screen surface with a soft, dry cloth. Perform a touch screen calibration from the Start Center. If inaccuracy persists after calibration, the resistive touch overlay may be worn and require replacement.
Panel fails to establish communication with the PLC
Verify the MPI or PROFIBUS-DP cable connections at both the panel and PLC ends. Check bus termination resistors are correctly placed at both ends of the network segment.
Replace or reseat the communication cable. Confirm that the panel's MPI/PROFIBUS address and baud rate in the WinCC flexible project match the PLC network settings. Ensure no address conflicts exist on the bus.
Panel repeatedly restarts or enters a boot loop
This may indicate a corrupt project file or a firmware issue. Attempt to access the Start Center by holding the touch screen during power-up.
From the Start Center, delete the existing project and re-transfer a valid project from WinCC flexible Compact. If the boot loop continues without a project loaded, update the panel firmware using ProSave.
Alarms are not displayed or alarm history is missing
Check the alarm configuration in the WinCC flexible project. Verify that the alarm buffer size is sufficient and that the correct PLC bit addresses are mapped to alarm triggers.
Increase the alarm buffer size in the project settings and re-transfer the project. Confirm PLC alarm bit addresses are correct and that the PLC program is setting the expected bits during fault conditions.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page