Siemens 6AV3017-1NE30-0AX0 SIMATIC OP 17
€ 353,00 – € 399,00Price range: € 353,00 through € 399,00
The Siemens 6AV3017-1NE30-0AX0 is an Operator Panel (OP 17) belonging to the SIMATIC HMI family, designed for operator control and monitoring tasks in industrial automation environments. This unit provides a compact, text-based interface for machine-level visualization and process control. It is part of Siemens' established OP series of operator panels, intended for integration with SIMATIC S5 and S7 programmable logic controllers.
The OP 17 features a backlit LCD display capable of showing text and simple graphics, with a matrix keyboard for operator input including function keys, numeric keys, and system keys. It supports communication via the MPI (Multi-Point Interface) and PROFIBUS-DP protocols, enabling direct connection to SIMATIC S7-200, S7-300, and S7-400 PLCs, as well as S5 controllers via appropriate adapters. The panel is configured using ProTool software and supports alarm management, recipe handling, and password-protected access levels. The unit operates on a 24 V DC supply and is rated for front-panel mounting with an IP65 protection rating on the front face.
The SIMATIC OP 17 is widely deployed in machine building, manufacturing automation, and process control applications where a robust, text-based operator interface is sufficient. It is commonly found on packaging machinery, conveyor systems, injection molding machines, and general-purpose industrial equipment. Its compact form factor and compatibility with the broad SIMATIC PLC portfolio make it a practical choice for retrofit and new installations in space-constrained control panels.
Technical Specifications
| Display Type | LCD, backlit |
|---|---|
| Display Lines | 8 lines of text |
| Characters per Line | 40 characters |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 8 W |
| Communication Interface | MPI, PROFIBUS-DP |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90%, non-condensing |
| Mounting | Panel mounting |
| Configuration Software | ProTool |
| Series/Product Family | SIMATIC OP 17 |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the OP 17 and the connected PLC. The panel cannot establish or maintain a connection.
Check MPI/PROFIBUS cable connections and termination resistors. Verify the PLC address and baud rate settings match the OP 17 configuration. Ensure the PLC is in RUN mode. - Event ID: 10001
- Timeout error on the MPI or PROFIBUS-DP interface. No response received from the configured PLC within the expected time.
Check physical wiring and bus termination. Verify the configured station address and communication parameters in ProTool match the PLC settings. - Event ID: 20000
- Configuration error detected. The project loaded on the OP 17 is incompatible or corrupted.
Re-download the project from ProTool to the OP 17. Verify the project was compiled without errors before transfer. - Event ID: 20001
- Memory error. Insufficient memory available to load or run the configured project.
Reduce the project size in ProTool by removing unused screens, alarms, or recipes. Re-download the project after optimization. - Event ID: 40000
- Operating system error or internal firmware fault detected on the OP 17.
Perform a cold restart of the panel. If the error persists, reload the operating system firmware using ProTool and re-download the project. - Event ID: 50000
- Alarm buffer overflow. The number of pending alarms exceeds the buffer capacity of the panel.
Acknowledge and clear existing alarms on the panel. Review the alarm configuration in ProTool to reduce simultaneous alarm triggers if this occurs frequently. - Event ID: 60000
- Recipe data error. A recipe transfer between the OP 17 and the PLC has failed or the recipe data is inconsistent.
Check the recipe configuration in ProTool for correct data block assignments. Re-transfer the recipe data and verify PLC data block availability.
Frequently Asked Questions
Which PLCs are compatible with the SIMATIC OP 17 (6AV3017-1NE30-0AX0)?
The OP 17 is compatible with SIMATIC S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS-DP. It can also connect to SIMATIC S5 controllers using appropriate interface adapters.
What software is used to configure and program the OP 17?
The OP 17 is configured using Siemens ProTool software. Projects are compiled in ProTool and downloaded to the panel via the MPI interface.
What is the supply voltage required for the 6AV3017-1NE30-0AX0?
The OP 17 requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range and adequately rated for the panel's power consumption.
What is the front panel protection rating of the OP 17?
The front face of the OP 17 carries an IP65 protection rating, making it suitable for panel-mount installations where dust and water spray protection is required.
Can the OP 17 handle alarm management and recipe functions?
Yes, the OP 17 supports alarm logging, alarm acknowledgment, and basic recipe management. These functions are configured within the ProTool project and communicated to the PLC via the configured interface.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for blown internal fuses or wiring faults.
Ensure the 24 V DC supply is within tolerance and correctly wired to the panel terminals. If the supply is correct and the display remains blank, the internal power supply or backlight may require replacement.
OP 17 displays a persistent communication error and cannot connect to the PLC
Verify the MPI or PROFIBUS-DP cable is correctly connected and terminated at both ends. Check that the station address and baud rate configured in ProTool match the PLC settings.
Correct any wiring or termination faults. Adjust the communication parameters in ProTool to match the PLC configuration and re-download the project. Replace the communication cable if it is damaged.
Function keys or numeric keys do not respond to input
Inspect the keypad membrane for physical damage, contamination, or wear. Test individual keys in the panel's built-in key test mode if available.
Clean the keypad surface if contamination is present. If individual keys are unresponsive due to membrane damage, the keypad membrane assembly will need to be replaced.
Project download from ProTool fails or is interrupted
Check the MPI cable connection between the programming device and the OP 17. Verify the ProTool project has been compiled without errors and that the correct panel type is selected in the project settings.
Replace the MPI programming cable if faulty. Recompile the ProTool project ensuring the correct OP 17 variant is selected, then retry the download. Ensure no other devices are actively communicating on the MPI bus during transfer.
Panel restarts unexpectedly or enters a boot loop
Check the 24 V DC supply for voltage dips or instability under load. Inspect the project for configuration errors that may cause a runtime fault on startup.
Stabilize the power supply by using a dedicated, adequately rated 24 V DC source. Re-download the operating system and project via ProTool. If the issue persists, the internal hardware may require inspection or replacement.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page