• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7613-0AE10-0CG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7613-0AE10-0CG0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7613-0AE10-0CG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7613-0AE10-0CG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC architecture, providing a compact and rugged computing platform for process visualization and control.

    The SIMATIC Panel PC 670 6AV7613-0AE10-0CG0 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation. It is based on an Intel processor platform and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is designed for panel mounting with a robust aluminum front bezel rated to IP65 on the front face.

    This Panel PC is widely used in manufacturing automation, process industries, and machine building where a full PC-based HMI solution is required. It is suitable for applications such as SCADA visualization, data logging, recipe management, and integration with Siemens SIMATIC S7 PLC systems. Industries including automotive, food and beverage, chemical processing, and packaging commonly deploy this unit for its combination of industrial robustness and standard PC flexibility.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 60 W
    Communication Interface Ethernet RJ45, USB, RS-232 (COM ports)
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    IP/Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100000
    Loss of connection to the PLC or communication partner. The HMI runtime cannot establish or maintain a connection to the configured controller.
    Check Ethernet or serial cable connections, verify PLC IP address configuration, and confirm the PLC is in RUN mode. Check firewall settings on the Panel PC.
    Event ID: 110000
    Tag read/write error. A configured tag could not be read from or written to the connected controller.
    Verify the tag address configuration in the HMI project matches the PLC data block structure. Check communication link integrity and PLC program.
    Event ID: 040000
    System memory low. The Panel PC operating system is reporting insufficient available RAM or virtual memory.
    Close unnecessary background applications, increase virtual memory settings in Windows, or consider upgrading RAM if the hardware supports it.
    Event ID: 070000
    Project download error. A project transfer from the engineering station to the Panel PC failed.
    Verify network connectivity between the engineering PC and the Panel PC, ensure the correct transfer channel is configured, and check that sufficient storage space is available on the Panel PC.
    Event ID: 080000
    Runtime software fault. The SIMATIC WinCC Runtime or HMI runtime application has encountered an internal error and terminated unexpectedly.
    Restart the runtime application. If the fault persists, reinstall the runtime software and restore the HMI project from a backup.
    Event ID: 050000
    Storage medium error. The internal hard disk or CompactFlash card is reporting read/write errors or is not detected.
    Check the storage medium connection internally. Run a disk check utility. Replace the hard disk or CompactFlash card if errors persist.
    Event ID: 060000
    Operating system startup failure. Windows fails to boot correctly, possibly due to corrupted system files.
    Attempt a Windows repair using the recovery console. If unsuccessful, perform a full OS reinstallation using the Siemens restore CD or recovery partition.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 6AV7613-0AE10-0CG0 run?

    This Panel PC is designed to run Microsoft Windows XP Professional or Windows 2000, and is compatible with SIMATIC WinCC and WinCC flexible runtime software.

    What is the display size and resolution of this unit?

    The 6AV7613-0AE10-0CG0 features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA).

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), multiple USB ports, and RS-232 serial interfaces, enabling connectivity to Siemens S7 PLCs and other automation devices.

    What is the front panel protection rating of this device?

    The front panel of the SIMATIC Panel PC 670 is rated to IP65, providing protection against dust ingress and water jets, making it suitable for industrial panel installation.

    Can this Panel PC be used with SIMATIC WinCC?

    Yes, the SIMATIC Panel PC 670 is fully compatible with SIMATIC WinCC and WinCC flexible, and is a standard platform for Siemens PC-based HMI and SCADA visualization applications.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC supply voltage is present at the power connector. Verify the power LED status. Attempt to connect an external monitor via the VGA port to determine if the issue is with the display or the PC itself.

    If the external monitor shows output, the internal display or backlight inverter may have failed and requires replacement. If no output is present on either display, check the internal power supply and fuses. Replace the backlight or inverter board as needed.

    Touch screen does not respond or is inaccurate

    Check if the touch controller driver is correctly installed in Windows Device Manager. Attempt to recalibrate the touch screen using the Siemens touch calibration utility in the Control Panel.

    Recalibrate the touch screen via the calibration tool. If the touch screen remains unresponsive, check the internal ribbon cable connection between the touch panel and the controller board. Replace the touch screen overlay if the hardware is damaged.

    Panel PC fails to boot Windows and shows a blue screen or stops at POST

    Attempt to boot from a known-good bootable USB or CD to determine if the issue is with the hard disk or the OS installation. Check the hard disk health using diagnostic tools.

    If the hard disk is faulty, replace it with a compatible unit and reinstall Windows using the Siemens restore media. If the issue is a corrupted OS, use the Windows recovery console to repair system files.

    Loss of communication with S7 PLC

    Verify the Ethernet cable connection and check the network configuration (IP address, subnet mask) on both the Panel PC and the PLC. Use the Windows ping command to test network reachability.

    Correct any IP address conflicts or misconfiguration. Replace the Ethernet cable if damaged. Ensure the correct communication driver (e.g., S7-1200/1500 or S7-300/400 Ethernet driver) is installed and configured in the HMI project.

    HMI runtime application crashes repeatedly

    Check the Windows Event Viewer for application error logs related to the WinCC runtime process. Verify that the installed runtime version is compatible with the HMI project version.

    Update or reinstall the WinCC runtime software to the correct version. Restore the HMI project from a verified backup. If crashes persist, check available disk space and RAM, and consider performing a full system restore using the Siemens recovery image.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart