Siemens 6AV7613-0AA30-0CH0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA30-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates computing hardware and a display into a single ruggedized enclosure suitable for direct panel mounting.
The SIMATIC Panel PC 670 with part number 6AV7613-0AA30-0CH0 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and a resistive touchscreen interface. It is based on an x86-compatible processor architecture and supports standard PC operating systems such as Windows XP Professional or Windows XP Embedded. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is built to withstand the vibration, temperature, and EMC requirements of industrial environments.
The SIMATIC Panel PC 670 is widely used in the automotive, food and beverage, pharmaceutical, and general manufacturing industries for machine-level visualization, SCADA front-end applications, and process monitoring. Its fanless or low-maintenance design options and compatibility with Siemens WinCC and other SCADA software make it suitable for continuous operation in production environments. The panel-mount form factor allows direct integration into control cabinets and operator stations.
Technical Specifications
| Series | SIMATIC Panel PC 670 |
|---|---|
| Display Size | 15 inch |
| Display Type | TFT LCD |
| Display Resolution | 1024 x 768 px (XGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| IP Rating (Front) | IP65 |
| Mounting | Panel mounting |
| Communication Interfaces | Ethernet (RJ45), USB, RS-232 |
| Operating System Support | Windows XP Professional / Windows XP Embedded |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Overtemperature warning — internal temperature has exceeded the defined threshold.
Check ambient temperature and ventilation around the panel. Clean air filters if present. Verify cooling fan operation. - Event ID: 300
- Watchdog timeout — the system watchdog has triggered due to application or OS hang.
Restart the panel PC. Investigate the application software for infinite loops or resource deadlocks. Update or reinstall the HMI runtime software. - Event ID: 400
- UPS battery low or UPS module fault detected.
Replace the UPS battery module. Verify UPS module seating and connections. Check UPS configuration in BIOS. - Event ID: 500
- Ethernet communication fault — network interface not detected or link failure.
Check Ethernet cable and switch port. Verify IP configuration in the operating system. Replace Ethernet cable or check network adapter driver. - Event ID: 600
- Touchscreen calibration error or touch input not responding.
Recalibrate the touchscreen using the Siemens calibration utility in the control panel. If unresponsive, check touchscreen controller connection internally or replace the touchscreen overlay. - Event ID: 700
- Hard disk or CompactFlash storage device not found or read error.
Reseat the storage device. Check BIOS detection of the drive. Replace the CompactFlash card or hard disk if the device is not recognized or reports errors.
Frequently Asked Questions
What is the supply voltage for the 6AV7613-0AA30-0CH0?
The SIMATIC Panel PC 670 6AV7613-0AA30-0CH0 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
What display size and resolution does this panel PC have?
This unit features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and a resistive touchscreen.
Which operating systems are compatible with this Panel PC?
The 6AV7613-0AA30-0CH0 supports Windows XP Professional and Windows XP Embedded. It is compatible with Siemens WinCC and other standard SCADA/HMI software packages.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 is rated IP65, providing protection against dust ingress and low-pressure water jets.
Can this Panel PC be used with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens WinCC visualization software, making it a common platform for SCADA and process visualization applications.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power input connector. Verify that the power LED indicator is illuminated. Measure voltage at the internal power supply output rails.
Ensure the 24 V DC supply is within tolerance. If the backlight is faulty, replace the CCFL backlight or the display assembly. If the power supply board is defective, replace the internal PSU module.
Touchscreen does not respond to input
Verify that the touchscreen is enabled in the operating system device manager. Check for touchscreen controller driver errors. Attempt recalibration using the Siemens touchscreen calibration utility.
Recalibrate the touchscreen. If the issue persists, check the internal ribbon cable connection between the touchscreen overlay and the controller board. Replace the touchscreen overlay if the controller detects no input signal.
Panel PC fails to boot or continuously restarts
Check the CompactFlash card or hard disk for errors using a bootable diagnostic tool. Inspect BIOS POST messages for hardware fault indications. Check for overtemperature conditions that may trigger automatic shutdown.
Replace the CompactFlash card or hard disk with a new unit and restore the operating system image. Reset BIOS to default settings if configuration corruption is suspected. Ensure adequate ventilation to prevent thermal shutdowns.
Ethernet communication not working
Verify the Ethernet cable and switch port are functional. Check the network adapter status in Windows Device Manager. Ping the device from another node on the network to confirm connectivity.
Replace the Ethernet cable. Reinstall or update the network adapter driver. If the onboard Ethernet port is physically damaged, use a USB-to-Ethernet adapter as a temporary measure or replace the mainboard.
System clock resets to incorrect date and time after power cycle
This typically indicates a depleted CMOS battery on the mainboard. Confirm by checking the BIOS clock after a full power-off cycle.
Replace the CMOS coin cell battery (typically CR2032) on the mainboard. After replacement, set the correct date and time in the BIOS and save settings.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page