Siemens 6AV7613-0AA30-0CE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA30-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC platform, providing a compact and rugged solution for process visualization and control.
The SIMATIC Panel PC 670 6AV7613-0AA30-0CE0 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports 65,536 colors. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, providing a standard PC environment for SCADA and HMI software such as WinCC. The unit offers multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is designed for panel mounting with an IP65-rated front face for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building where a robust, integrated PC-based HMI solution is required. It is suitable for applications in automotive production lines, chemical processing plants, and packaging machinery where reliable visualization and operator control are essential. Its compatibility with Siemens SIMATIC software and standard PC peripherals makes it a versatile platform for complex visualization tasks.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Colors | 65,536 colors |
| Display Type | TFT LCD |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Communication Interface | Ethernet (RJ45), USB, RS-232 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup error — Windows failed to start correctly, possibly due to corrupted system files or failed boot device.
Check the hard disk or CompactFlash card for errors. Attempt system recovery or restore from backup image. - Event ID: 200
- Hardware watchdog timeout — The watchdog timer was not reset within the defined interval, indicating a system hang or software freeze.
Restart the Panel PC. Check the application software for infinite loops or deadlocks. Update or reinstall the HMI runtime software. - Event ID: 300
- Fan failure detected — The system cooling fan has stopped or is running below the required speed threshold.
Check and clean the fan. Replace the fan unit if it is defective to prevent thermal shutdown. - Event ID: 400
- Temperature warning — Internal system temperature has exceeded the warning threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean air filters and verify fan operation. - Event ID: 500
- Battery low warning — The CMOS/RTC backup battery voltage is below the minimum threshold.
Replace the internal lithium backup battery (typically CR2032 or equivalent) to prevent loss of BIOS settings and real-time clock data. - Event ID: 600
- Storage medium error — Read/write error detected on the hard disk or CompactFlash storage device.
Run a disk check utility. Replace the storage medium if errors persist and restore the system image from backup. - Event ID: 700
- Communication interface error — Loss of communication on the Ethernet or serial interface.
Check cable connections and network configuration. Verify IP address settings and ensure the connected controller or network device is operational.
Frequently Asked Questions
What is the display size and resolution of the 6AV7613-0AA30-0CE0?
The 6AV7613-0AA30-0CE0 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and 65,536 colors.
What operating voltage does the SIMATIC Panel PC 670 6AV7613-0AA30-0CE0 require?
This Panel PC operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in automation environments.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces, allowing connectivity to PLCs, networks, and peripheral devices.
What is the front panel protection rating of the 6AV7613-0AA30-0CE0?
The front face of the panel is rated IP65, providing protection against dust and low-pressure water jets, making it suitable for industrial environments.
Is the SIMATIC Panel PC 670 compatible with Siemens WinCC software?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other SIMATIC HMI software packages, as it operates on a standard Windows-based PC platform.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is active. Measure voltage at the internal power supply output.
Ensure the 24 V DC supply is within tolerance. If the supply is correct but the display remains blank, check the internal power supply board and display backlight inverter for faults. Replace defective components as necessary.
Panel PC fails to boot into the operating system
Listen for POST beep codes and observe any error messages on screen during startup. Check the hard disk or CompactFlash card connection and integrity.
Re-seat the storage medium. Run a disk check or attempt to restore the factory system image. If the storage device is faulty, replace it and reinstall the operating system and HMI software.
Touchscreen does not respond or is inaccurate
Check whether the touchscreen controller is recognized in the operating system device manager. Verify that the touch calibration has not been corrupted.
Recalibrate the touchscreen using the built-in calibration utility in the Windows control panel. If the touchscreen remains unresponsive, check the ribbon cable connection between the touch panel and the controller board, and replace the touch overlay if damaged.
Loss of Ethernet communication with PLC or SCADA system
Check the Ethernet cable and connector for physical damage. Verify the IP address configuration in the operating system network settings. Ping the target device to test connectivity.
Replace the Ethernet cable if damaged. Correct the IP address, subnet mask, and gateway settings. If the onboard Ethernet port is faulty, replace the network interface card or use an alternative USB Ethernet adapter.
System clock resets to incorrect date and time after power off
This typically indicates that the CMOS backup battery is depleted and no longer maintaining the real-time clock when main power is removed.
Replace the internal CMOS/RTC lithium backup battery with the correct type as specified in the Siemens SIMATIC Panel PC 670 hardware manual. After replacement, set the correct date and time in the BIOS settings.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page