• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7613-0AA22-0AJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7613-0AA22-0AJ0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7613-0AA22-0AJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7613-0AA22-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7613-0AA22-0AJ0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an x86-compatible processor and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides standard PC interfaces including USB, serial (COM), and Ethernet ports, and is built with an aluminum front panel rated to IP65 for protection against dust and water ingress from the front side.

    This Panel PC is widely used in the manufacturing, automotive, chemical, and food and beverage industries for machine-level and plant-level visualization. Its fanless or low-maintenance design options make it suitable for environments where reliability and reduced maintenance intervals are critical. The integration capability with Siemens SIMATIC S7 PLCs and PROFIBUS/PROFINET networks makes it a natural fit for Siemens-based automation architectures.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM)
    Operating System Microsoft Windows XP / Windows CE (variant dependent)
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly or a hardware initialization error occurred during POST.
    Check the storage medium (CompactFlash or hard disk) for integrity. Reseat memory modules and verify all internal connections. Reload or reinstall the operating system if necessary.
    Event ID: 1000
    Application fault — a WinCC or HMI runtime application has crashed or become unresponsive.
    Restart the HMI runtime application. Check the application event log for details. Update or reinstall the WinCC runtime software if the fault persists.
    Event ID: 7000
    Service failed to start — a required Windows service did not start during system boot.
    Check the Windows Event Viewer for the specific service name. Ensure the service is set to automatic startup and that all dependencies are running.
    Communication Error
    Loss of communication between the Panel PC and the connected PLC or PROFIBUS/PROFINET network.
    Verify Ethernet or PROFIBUS cable connections. Check IP address configuration and network settings. Confirm the PLC is online and the correct communication driver is configured in WinCC.
    Watchdog Timeout
    The system watchdog has triggered due to the operating system or application becoming unresponsive.
    Perform a controlled restart of the Panel PC. Investigate CPU load and running processes. If recurring, check for software conflicts or hardware faults on the motherboard.
    Temperature Warning
    Internal temperature of the Panel PC has exceeded the normal operating threshold.
    Check that ventilation slots are not blocked. Verify ambient temperature is within the specified operating range (0 °C to +50 °C). Clean any dust filters or cooling surfaces.
    Display Backlight Fault
    The display backlight has failed or is operating below normal brightness levels.
    Replace the backlight inverter board or the TFT display assembly. Check the backlight power connector for secure contact.
    Storage Medium Error
    The CompactFlash card or hard disk drive is not detected or has reported read/write errors.
    Reseat the CompactFlash card or HDD. Replace the storage medium if errors persist. Restore the operating system and application software from a backup image.

    Frequently Asked Questions

    What operating systems are supported by the SIMATIC Panel PC 670 (6AV7613-0AA22-0AJ0)?

    The SIMATIC Panel PC 670 supports Microsoft Windows XP Professional and Windows XP Embedded, depending on the specific variant ordered. It is compatible with Siemens SIMATIC WinCC and WinCC flexible HMI software.

    What is the supply voltage for this Panel PC?

    The 6AV7613-0AA22-0AJ0 operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 series devices.

    Is the 6AV7613-0AA22-0AJ0 compatible with SIMATIC S7 PLCs?

    Yes, this Panel PC is fully compatible with Siemens SIMATIC S7-300 and S7-400 PLCs via Ethernet (PROFINET) or PROFIBUS communication interfaces when configured with the appropriate WinCC drivers.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7613-0AA22-0AJ0 is rated to IP65, providing complete protection against dust ingress and protection against low-pressure water jets.

    Can the display or touchscreen be replaced as a spare part?

    Yes, the TFT display assembly and resistive touchscreen digitizer are available as spare parts and can be replaced by a qualified technician. It is recommended to source replacement parts from Siemens or an authorized repair center.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power input connector. Verify the backlight inverter is receiving power and listen for the startup beep indicating the PC has posted successfully.

    If the PC is booting but the display is blank, replace the backlight inverter or TFT display assembly. If there is no power at all, check the external power supply and internal fuse.

    Touchscreen does not respond or registers incorrect touch positions

    Check if the touchscreen is calibrated correctly within the operating system. Inspect the touchscreen ribbon cable connection to the controller board for damage or looseness.

    Recalibrate the touchscreen using the Windows calibration utility. If calibration does not resolve the issue, replace the resistive touchscreen digitizer overlay.

    Panel PC fails to boot and shows a black screen with no POST activity

    Reseat the CompactFlash card or hard disk drive and RAM modules. Attempt to boot from an external USB device to determine if the storage medium has failed.

    Replace the CompactFlash card or HDD and reinstall the operating system and WinCC runtime from a backup image. If the unit still does not POST, the motherboard may require replacement or professional repair.

    Loss of communication with the PLC during operation

    Check the Ethernet or PROFIBUS cable connections at both the Panel PC and the PLC. Verify the IP address settings and subnet configuration in WinCC and the network adapter settings.

    Replace faulty cables or connectors. Reconfigure the network settings to ensure the Panel PC and PLC are on the same subnet. Restart the WinCC runtime and re-establish the communication channel.

    Unit overheats and shuts down unexpectedly

    Inspect the rear ventilation area for dust accumulation or blockage. Measure the ambient temperature at the installation location to confirm it is within the 0 °C to +50 °C operating range.

    Clean all ventilation surfaces and ensure adequate clearance around the unit for airflow. If the ambient temperature is too high, install additional cabinet cooling. Check that the internal fan (if fitted) is operating correctly.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart