• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7613-0AA22-0AG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7613-0AA22-0AG0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7613-0AA22-0AG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7613-0AA22-0AG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, offering a compact and rugged all-in-one solution for process visualization and control.

    The SIMATIC Panel PC 670 6AV7613-0AA22-0AG0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 256 colors, integrated with a resistive touchscreen for operator input. The unit is based on an x86-compatible processor architecture and supports standard PC interfaces including USB, serial (RS-232), and Ethernet (RJ45) for connectivity to PLCs and SCADA systems. It is designed to run Windows-based operating systems and supports Siemens WinCC and ProTool/Pro HMI software, with onboard flash memory and optional hard disk storage. The device operates on a 24 V DC supply and is built to IEC 61131-2 standards for industrial environments.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building industries where a full PC-based HMI platform is required. It is suitable for applications such as SCADA visualization, recipe management, data logging, and integration with Siemens SIMATIC S7 PLC families. Its panel-mount design and industrial-grade construction make it appropriate for installation in control cabinets and operator panels in sectors including automotive, food and beverage, and chemical processing.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP Rating (Front) IP65
    Mounting Panel mounting
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM port)
    Operating System Windows XP / Windows CE compatible
    HMI Software Compatibility Siemens WinCC, ProTool/Pro
    Series SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST sequence.
    Check hard disk or flash memory integrity. Verify OS installation. Replace storage media if corrupted.
    Event ID: 200
    Touchscreen calibration lost or touch input not responding correctly.
    Recalibrate the touchscreen via the Windows control panel or BIOS utility. If persistent, check touchscreen controller connection or replace the touch overlay.
    Event ID: 300
    Ethernet communication failure — no link detected on the network interface.
    Check Ethernet cable and switch port. Verify IP configuration in Windows network settings. Test with a known-good cable.
    Event ID: 400
    Internal temperature warning — CPU or system temperature exceeds threshold.
    Check ventilation around the panel. Clean any dust from vents or cooling surfaces. Verify ambient temperature is within specification (0–50 °C).
    Event ID: 500
    HMI runtime application (WinCC/ProTool) failed to start or terminated unexpectedly.
    Check WinCC or ProTool/Pro installation integrity. Review Windows event log for application errors. Reinstall HMI runtime software if necessary.
    Event ID: 600
    24 V DC supply undervoltage detected — supply voltage below operating threshold.
    Measure supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within tolerance. Replace power supply if out of range.
    Event ID: 700
    USB device not recognized or USB port fault.
    Disconnect and reconnect the USB device. Try an alternative USB port. Check Windows Device Manager for driver conflicts or hardware errors.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7613-0AA22-0AG0?

    The unit operates on a 24 V DC supply voltage, which is the standard industrial supply for SIMATIC Panel PC 670 devices.

    What HMI software is compatible with this Panel PC?

    The 6AV7613-0AA22-0AG0 is compatible with Siemens WinCC and ProTool/Pro HMI software packages, enabling integration with SIMATIC S7 PLC systems.

    What is the display size and resolution of this unit?

    The panel features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and resistive touch input.

    What is the front panel protection rating?

    The front panel of the 6AV7613-0AA22-0AG0 carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.

    Can this Panel PC communicate with Siemens S7 PLCs?

    Yes, the unit supports Ethernet and serial communication interfaces, allowing direct connectivity to Siemens SIMATIC S7-300 and S7-400 PLCs using standard Siemens communication drivers.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector. Verify that the supply is within tolerance and that the power LED indicator is active. Inspect the internal fuse if accessible.

    Restore correct 24 V DC supply. If supply is confirmed good, the internal power supply board or backlight inverter may be faulty and require replacement.

    Touchscreen does not respond or registers incorrect touch positions

    Attempt touchscreen recalibration through the Windows control panel. Check for physical damage to the touch overlay or contamination on the screen surface.

    Recalibrate the touchscreen using the calibration utility. If calibration fails repeatedly, replace the resistive touch overlay or the touchscreen controller board.

    WinCC or ProTool/Pro runtime fails to start after Windows boot

    Review the Windows event log for application or system errors. Check available disk space on the storage media and verify the integrity of the HMI software installation.

    Free up disk space if required, then repair or reinstall the WinCC or ProTool/Pro runtime software. If the storage media is corrupted, replace it and restore from a backup image.

    No Ethernet communication with PLC or network

    Check the Ethernet cable connection and verify the link LED on the RJ45 port is active. Confirm IP address configuration in Windows network settings matches the network subnet.

    Replace the Ethernet cable if no link LED is present. Reconfigure the IP address settings. If the network adapter is not detected in Device Manager, the onboard NIC may require driver reinstallation or hardware replacement.

    Unit reboots unexpectedly or freezes during operation

    Monitor the operating temperature of the unit and check that ambient temperature is within the 0–50 °C specification. Review Windows event logs for critical system errors or hardware faults.

    Improve ventilation around the panel installation. If overheating is not the cause, check RAM seating and storage media health. A persistent issue may indicate a failing mainboard requiring replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart