Siemens 6AV7613-0AA13-0CJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA13-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7613-0AA13-0CJ0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors, providing clear visualization of process data. It is equipped with a resistive touchscreen for operator input and runs on a Windows-based operating system, supporting SIMATIC WinCC and other HMI software packages. The unit provides standard PC interfaces including USB, serial (RS-232), and Ethernet ports, enabling integration with Siemens SIMATIC controllers and third-party systems. The fanless design and solid-state storage options enhance reliability in industrial environments.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building where a robust, panel-mounted PC-based HMI is required. It is suitable for applications in automotive production, food and beverage processing, chemical plants, and packaging machinery. Its industrial-grade construction and compatibility with Siemens SIMATIC software make it a practical choice for supervisory control and data acquisition (SCADA) and advanced visualization tasks.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 64,000 colors |
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP Protection Rating | IP65 (front panel) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and re-seat storage media. Replace storage device if faulty. - Event ID: 200
- Watchdog timeout triggered, indicating the application software stopped responding.
Restart the Panel PC. Check the HMI application for software errors or infinite loops. Update or reinstall the HMI software if the issue persists. - Event ID: 300
- Communication loss to PLC or controller detected on the Ethernet or serial interface.
Check network cable connections and switch/hub status. Verify IP address configuration and PLC communication settings in WinCC or the HMI project. - Event ID: 400
- Touchscreen calibration error or touch input not responding correctly.
Perform touchscreen recalibration via the Windows control panel or SIMATIC HMI settings. Clean the touch surface and check for physical damage to the overlay. - Event ID: 500
- Internal temperature warning — panel PC operating temperature has exceeded the recommended threshold.
Check ambient temperature and ensure adequate ventilation around the panel cutout. Clean any dust from ventilation areas and verify the installation environment meets specifications. - Event ID: 600
- Power supply voltage out of range — input voltage below or above the 24 V DC nominal value.
Measure the 24 V DC supply at the power connector. Ensure the power supply unit is rated for the Panel PC load and that wiring connections are secure. - Event ID: 700
- Storage media error detected — read/write failure on hard disk or CompactFlash card.
Back up data immediately if possible. Run a disk check utility. Replace the storage media with a compatible unit and restore the operating system and HMI project.
Frequently Asked Questions
What is the supply voltage for the 6AV7613-0AA13-0CJ0?
The SIMATIC Panel PC 670 (6AV7613-0AA13-0CJ0) operates on a 24 V DC power supply.
What display size and resolution does this Panel PC have?
The unit features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 64,000 colors.
Is the 6AV7613-0AA13-0CJ0 compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run SIMATIC WinCC and other Siemens HMI software packages on its Windows-based operating system.
What is the front panel protection rating of this unit?
The front panel of the 6AV7613-0AA13-0CJ0 carries an IP65 protection rating, making it suitable for panel-mounted installations in industrial environments where dust and water ingress protection is required.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), RS-232 serial, and USB interfaces for connectivity to PLCs, networks, and peripheral devices.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the power LED indicator is active. Inspect internal fuses if accessible.
Ensure the 24 V DC supply is within tolerance. Replace any blown internal fuses. If the backlight has failed, the display unit or inverter board may require replacement.
Touchscreen does not respond or registers incorrect touch positions
Determine whether the issue is a calibration problem or a hardware fault by attempting recalibration. Check for physical damage or contamination on the touch overlay.
Recalibrate the touchscreen through the Windows control panel or SIMATIC HMI configuration tool. If calibration fails repeatedly, the resistive touch overlay may be damaged and should be replaced.
Panel PC fails to boot or continuously restarts
Check for POST error messages on the display during startup. Inspect the storage media (hard disk or CompactFlash) for errors using diagnostic tools if the system partially boots.
Re-seat the storage media and verify BIOS settings. If the storage device is faulty, replace it with a compatible unit and reinstall the operating system and HMI application software.
Loss of communication with the connected PLC or SCADA system
Verify Ethernet cable connections and check network switch status. Confirm the IP address configuration on both the Panel PC and the PLC. Check for firewall or software communication settings in WinCC.
Replace the Ethernet cable if damaged. Correct IP address or subnet configuration errors. Restart the communication driver in WinCC or reconfigure the PLC connection in the HMI project.
Panel PC overheating warning or unexpected shutdown due to high temperature
Check the ambient temperature around the panel installation. Inspect ventilation openings for dust blockage. Verify that the panel cutout dimensions allow adequate airflow as specified in the installation guidelines.
Reduce ambient temperature or improve cabinet ventilation. Clean dust from all ventilation areas. Ensure the installation environment does not exceed the 0 °C to +50 °C operating temperature range specified for this unit.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page