Siemens 6AV7613-0AA12-0CH0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA12-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 6AV7613-0AA12-0CH0 is built around an industrial-grade processor and runs a Windows-based operating system, supporting SIMATIC WinCC and other Siemens HMI software packages. It features a 12-inch TFT display with touch screen capability, enabling intuitive operator interaction. The unit provides standard PC interfaces including USB, serial (COM), and Ethernet ports for connectivity to PLCs and higher-level systems. It is designed for fanless or low-noise operation with an industrial-hardened enclosure suitable for panel mounting.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, process industries, and machine automation where a full PC-based HMI platform is required. Its compatibility with Siemens SIMATIC software and standard PC peripherals makes it suitable for complex visualization tasks, data logging, and recipe management. Industries such as automotive, food and beverage, chemical processing, and discrete manufacturing commonly use this platform for supervisory control and operator interface stations.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM) |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| IP/Protection Rating | IP65 (front panel) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST.
Check hard disk or CompactFlash card integrity. Verify boot device is correctly configured in BIOS. Replace storage medium if faulty. - Event ID: 200
- Watchdog timeout — the system did not respond within the defined watchdog interval.
Check CPU load and running processes. Restart the Panel PC. If recurring, investigate software causing high CPU utilization or replace the unit. - Event ID: 300
- Fan failure or thermal warning — internal temperature has exceeded threshold.
Check ventilation around the panel. Clean any air filters or vents. Verify ambient temperature is within specification. Replace fan if faulty. - Event ID: 400
- Power supply undervoltage — supply voltage dropped below the permissible 24 V DC threshold.
Measure supply voltage at the power connector. Ensure the power supply unit provides stable 24 V DC within tolerance. Check wiring and connections. - Event ID: 500
- Hard disk or storage medium error — read/write failure detected on the internal storage device.
Run disk diagnostics. Back up data immediately. Replace the hard disk or CompactFlash card as appropriate. - Event ID: 600
- Communication interface error — loss of communication on Ethernet or serial interface.
Check cable connections and network configuration. Verify IP address settings and PLC communication parameters in WinCC or the HMI application. - Event ID: 700
- Touch screen calibration error — touch input is not responding correctly or is misaligned.
Perform touch screen recalibration via the Windows control panel or SIMATIC HMI settings. If calibration fails, check the touch controller hardware.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 6AV7613-0AA12-0CH0 run?
The SIMATIC Panel PC 670 is designed to run Windows XP Embedded or Windows 2000, depending on the specific configuration ordered. It supports Siemens SIMATIC WinCC and ProTool/Pro software for HMI applications.
What is the supply voltage for this Panel PC?
The 6AV7613-0AA12-0CH0 operates on a 24 V DC supply voltage. Ensure the power supply is stable and within the permissible tolerance range.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 meets IP65 protection, making it resistant to dust and water jets, suitable for panel-mounted installations in industrial environments.
Is this Panel PC compatible with Siemens SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with SIMATIC WinCC and other Siemens HMI visualization software packages, as it is a standard PC-based platform running a Windows operating system.
What communication interfaces are available on this unit?
The 6AV7613-0AA12-0CH0 provides Ethernet (RJ45), USB ports, and RS-232 serial (COM) interfaces for connecting to PLCs, peripherals, and network infrastructure.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the internal fuse and power supply board are functional. Confirm the backlight inverter is operating.
Restore correct 24 V DC supply. Replace the internal fuse if blown. If the backlight has failed, replace the backlight inverter or the display assembly.
Touch screen does not respond or responds inaccurately
Determine whether the issue is a calibration problem or a hardware failure. Test touch response in the Windows environment outside of the HMI application.
Recalibrate the touch screen via the Windows control panel. If calibration does not resolve the issue, inspect the touch controller board and ribbon cable connections. Replace the touch screen assembly if hardware is defective.
Panel PC fails to boot or continuously restarts
Check the storage medium (hard disk or CompactFlash card) for errors. Verify BIOS settings and boot order. Check for corrupted operating system files.
Run disk diagnostics and repair or replace the storage medium. Reinstall the operating system and HMI software if corruption is confirmed. Verify BIOS configuration is correct.
Loss of communication with PLC or network
Check Ethernet cable integrity and connection at both the Panel PC and the switch or PLC. Verify IP address configuration and subnet settings in the operating system and WinCC project.
Replace faulty Ethernet cable. Reconfigure network settings to match the PLC network. Ensure the correct communication driver is installed and active in the WinCC project.
Unit overheating or thermal shutdown
Check ambient temperature around the panel installation. Inspect ventilation openings for blockages. Verify that the internal fan (if fitted) is operating correctly.
Ensure ambient temperature is within the 0 °C to +45 °C operating range. Clear any obstructions from ventilation openings. Replace the internal fan if it has failed.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page