• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7613-0AA12-0BG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7613-0AA12-0BG0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7613-0AA12-0BG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7613-0AA12-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, providing a compact and robust solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7613-0AA12-0BG0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an x86-compatible processor platform and runs Microsoft Windows operating systems, enabling compatibility with standard SCADA and HMI software including Siemens WinCC. The unit provides multiple communication interfaces including Ethernet (RJ45) and serial ports, and is designed with a fanless or low-maintenance cooling concept suited to industrial environments. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process industries, and machine building applications where a full PC-based HMI platform is required. It is suitable for use in automotive production lines, food and beverage processing, chemical plants, and packaging machinery. Its compatibility with standard Windows software and Siemens automation systems makes it a practical choice for integrators requiring flexible visualization and data acquisition capabilities.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    IP Protection Rating (Front) IP65
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), RS-232, RS-422/485
    Operating System Windows XP / Windows 2000
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 1000
    Application error in the HMI runtime software, typically WinCC flexible or WinCC Runtime.
    Restart the HMI runtime application. Check Windows Event Viewer for detailed error logs and verify software installation integrity.
    Event ID: 100
    Connection to PLC or controller lost. Communication link between the Panel PC and the automation controller has been interrupted.
    Check Ethernet or serial cable connections. Verify PLC IP address settings and ensure the controller is powered and running.
    Event ID: 110
    Tag read/write error. A process variable (tag) could not be read from or written to the connected controller.
    Verify the tag address configuration in the HMI project. Check PLC program to confirm the data block or address exists and is accessible.
    Event ID: 40
    System memory low. Available RAM or virtual memory on the Panel PC has dropped below the required threshold.
    Close unnecessary applications running in the background. Consider increasing virtual memory settings in Windows or upgrading RAM if the hardware supports it.
    Event ID: 70
    License for HMI runtime software not found or invalid.
    Check that the WinCC or HMI software license dongle is properly connected. Verify license validity using Siemens Automation License Manager.
    Event ID: 130
    Project transfer error. A project download from the engineering station to the Panel PC failed.
    Check the network connection between the engineering PC and the Panel PC. Ensure the correct IP address is configured and that no firewall is blocking the transfer port.
    Event ID: 10
    Panel PC startup error. The system failed to complete the boot sequence correctly.
    Check the 24 V DC power supply voltage and connections. Verify that the operating system boots correctly and that no hardware faults are present.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 (6AV7613-0AA12-0BG0) run?

    The 6AV7613-0AA12-0BG0 is designed to run Microsoft Windows XP or Windows 2000, enabling compatibility with standard industrial HMI and SCADA software packages including Siemens WinCC.

    What is the display size and resolution of this Panel PC?

    This unit features a 12-inch TFT color LCD display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen interface.

    What is the supply voltage for the 6AV7613-0AA12-0BG0?

    The Panel PC 670 operates on a 24 V DC supply voltage, which is standard for Siemens industrial HMI and Panel PC products.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45) for network and PLC communication, as well as RS-232 and RS-422/485 serial interfaces for legacy device connectivity.

    Is the front panel of this unit protected against dust and water?

    Yes, the front panel of the SIMATIC Panel PC 670 meets IP65 protection rating, providing full protection against dust ingress and protection against low-pressure water jets.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the power LED indicator is illuminated. Listen for fan or hard disk activity to determine if the PC is booting.

    Ensure the 24 V DC supply is within tolerance. If the PC is booting but the display is blank, check the display backlight and video signal settings in BIOS. Replace the backlight inverter or display unit if the backlight has failed.

    Touch screen does not respond or is inaccurate

    Attempt to operate the unit using an external USB mouse or keyboard to determine if the issue is isolated to the touch screen. Check Device Manager in Windows for touch screen controller errors.

    Recalibrate the touch screen using the Windows touch screen calibration utility. If calibration does not resolve the issue, check the touch screen controller connection internally or replace the touch screen assembly.

    Panel PC fails to boot into Windows

    Observe the boot sequence on the display. Check for BIOS POST error messages or Windows startup error screens. Attempt to boot from an external device to determine if the internal storage device has failed.

    If the hard disk or CompactFlash storage has failed, replace it and reinstall the operating system and HMI software. Restore the project from a backup. Ensure BIOS settings are correctly configured for the installed storage device.

    Loss of communication with PLC or controller

    Check the Ethernet cable connection and verify the link LED on the RJ45 port is active. Use the Windows ping command to test network connectivity to the PLC IP address. Verify IP address and subnet mask configuration on both devices.

    Replace the Ethernet cable if faulty. Correct IP address or subnet configuration as needed. Check PLC communication settings and ensure the correct communication driver is configured in the HMI project.

    HMI runtime software crashes or freezes repeatedly

    Check Windows Event Viewer for application or system error logs. Monitor CPU and RAM usage using Task Manager to identify resource exhaustion. Verify that the HMI project is compatible with the installed runtime software version.

    Update or reinstall the WinCC runtime software. Ensure the HMI project was compiled with a compatible engineering software version. If hardware resources are insufficient, reduce the number of background processes or consider upgrading the Panel PC.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart