• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7613-0AA12-0AG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7613-0AA12-0AG0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7613-0AA12-0AG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7613-0AA12-0AG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in industrial automation environments. This unit integrates a flat-panel display with a full PC platform, providing both operator interface and computing functionality in a single device.

    The SIMATIC Panel PC 670 (6AV7613-0AA12-0AG0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is based on an x86-compatible processor architecture running a Windows-based operating system. It is equipped with standard PC interfaces including USB ports, serial COM ports, and an Ethernet interface for network connectivity and integration with SIMATIC WinCC or other SCADA/HMI software packages. The unit is designed for panel mounting and features a robust aluminum front frame with IP65 protection rating on the front face, making it suitable for installation in control cabinet doors.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a full PC-based HMI solution is required. Its compatibility with standard Windows software and Siemens SIMATIC WinCC visualization software makes it suitable for complex visualization tasks, data logging, and process monitoring. Typical industries include automotive manufacturing, food and beverage processing, chemical plants, and general factory automation.

    Technical Specifications

    Display Size 12 inch
    Display Type TFT LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 256,000 colors
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front), IP20 (rear)
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM ports)
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5% to 95% (non-condensing)
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Operating System Windows XP / Windows 2000 (factory configurable)

    Common Error Codes & System Events

    STOP (Red LED)
    The Panel PC has entered a STOP state, typically due to a critical software or hardware fault preventing normal operation.
    Perform a controlled restart. Check Windows Event Viewer for critical errors. Verify that all hardware components are properly seated and that the operating system is intact.
    Watchdog Timeout
    The system watchdog timer has expired, indicating the operating system or application has become unresponsive.
    Restart the Panel PC. Investigate application software for infinite loops or resource deadlocks. Ensure adequate CPU and memory resources are available for the running HMI application.
    Fan Failure Warning
    The internal cooling fan has failed or is operating below the required speed threshold.
    Power down the unit and inspect or replace the internal cooling fan. Continued operation without adequate cooling may cause thermal shutdown or hardware damage.
    Hard Disk Error
    The system has detected a read/write error or failure on the internal hard disk drive.
    Run a disk diagnostic utility (e.g., chkdsk). Back up data immediately if possible. Replace the hard disk drive and reinstall the operating system and HMI software.
    Battery Low Warning
    The CMOS/RTC backup battery voltage is below the minimum threshold, risking loss of BIOS settings and system time.
    Replace the internal CMOS lithium battery (typically CR2032). After replacement, reconfigure BIOS settings and verify system date and time.
    Ethernet Link Down
    The Ethernet interface has lost its network connection, interrupting communication with PLCs or SCADA servers.
    Check the Ethernet cable and switch/hub connection. Verify network configuration (IP address, subnet mask) in Windows network settings. Test with a known-good cable.
    Temperature Warning
    The internal temperature sensor has detected an elevated temperature approaching the maximum operating limit.
    Check that ventilation slots are not blocked. Verify the cooling fan is operational. Ensure ambient temperature is within the specified 0 °C to 45 °C operating range.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7613-0AA12-0AG0?

    The SIMATIC Panel PC 670 (6AV7613-0AA12-0AG0) operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices.

    What HMI software is compatible with this Panel PC?

    The unit is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other standard Windows-based SCADA and HMI software packages, as it runs a Windows operating system on an x86 platform.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7613-0AA12-0AG0 carries an IP65 protection rating, making it resistant to dust ingress and water jets, suitable for installation in control cabinet doors.

    What display size and resolution does this Panel PC have?

    The unit features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports up to 256,000 colors.

    Can this Panel PC be used as a replacement for older SIMATIC Panel PC 670 variants?

    In many cases yes, provided the hardware configuration (processor, memory, storage) and software licenses are compatible. Always verify the exact hardware revision and operating system version before substitution in an existing installation.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC supply is present at the power connector. Measure voltage at the input terminals. Inspect the internal fuse and verify the backlight inverter is functioning.

    Restore correct 24 V DC supply if absent. Replace a blown internal fuse with the correct rating. If the backlight inverter or display panel is faulty, replace the defective component or the display assembly.

    Panel PC boots to BIOS and does not load the operating system

    The hard disk drive may have failed or the boot order in BIOS may be incorrect. Connect a monitor via the external VGA port to observe POST messages and BIOS output.

    Enter BIOS setup and verify the correct boot device is selected. Run a disk diagnostic. If the hard disk has failed, replace it and reinstall the operating system and HMI application software.

    Touchscreen does not respond or is inaccurate

    The touchscreen controller driver may be corrupted, or the touch overlay may be physically damaged. Check Device Manager in Windows for driver errors related to the touch controller.

    Recalibrate the touchscreen using the Windows calibration utility or the Siemens touchscreen calibration tool. Reinstall the touchscreen driver if errors are present. If the touch overlay is physically damaged, replace the touch panel assembly.

    Unit loses date and time settings after power off

    The internal CMOS backup battery is depleted and can no longer maintain BIOS settings when main power is removed.

    Replace the internal CMOS lithium battery (typically a CR2032 coin cell). After replacement, re-enter BIOS settings and set the correct date and time. Synchronize with an NTP server if network time synchronization is configured.

    Ethernet communication to PLC or SCADA server is intermittent or lost

    Check the physical Ethernet connection, cable integrity, and switch port status. Verify the IP address configuration in Windows network settings has not changed. Check for IP address conflicts on the network.

    Replace the Ethernet cable if damaged. Assign a static IP address to avoid DHCP-related issues. If the onboard Ethernet adapter is faulty, install a compatible USB-to-Ethernet adapter or replace the motherboard.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart