
Siemens 6AV7613-0AA10-0AF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7613-0AA10-0AF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for machine-level and process-level control visualization.
The SIMATIC Panel PC 670 6AV7613-0AA10-0AF0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, providing compatibility with standard SCADA and HMI software including Siemens WinCC. The unit supports communication via Ethernet (RJ45) and serial interfaces, and is designed for panel mounting with a protection rating of IP65 on the front face.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a robust, integrated PC-based HMI solution is required. Its fanless or low-maintenance design makes it suitable for environments with dust or vibration, such as automotive production lines, food and beverage processing, and chemical plants. The panel PC format allows direct integration into control cabinets or machine panels, reducing installation footprint and cabling complexity.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Communication Interface | Ethernet (RJ45), RS-232, RS-422/485 |
| Operating System | Windows XP Embedded / Windows 2000 |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 1000
- Application error in the HMI runtime software, typically caused by a software exception or crash in the WinCC or ProTool runtime environment.
Restart the HMI runtime application. Check the Windows event log for details. Reinstall or repair the runtime software if the error persists. - Event ID: 7036
- A system service has stopped unexpectedly, which may affect HMI communication or display functionality.
Check Windows Services to identify which service stopped. Restart the affected service and configure it to restart automatically if needed. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or controller, resulting in no data exchange on the configured interface.
Verify Ethernet or serial cable connections. Check IP address configuration and network settings. Confirm PLC is powered and running. Restart the communication driver in WinCC. - Watchdog Timeout
- The system watchdog has detected that the operating system or application has become unresponsive and has triggered a reset.
Check for excessive CPU load or memory usage. Ensure no background processes are consuming resources. Update or reinstall the runtime software. Check hardware for faults such as failing storage media. - Drive Read/Write Error
- The CompactFlash card or hard disk drive is reporting read or write errors, which may cause data loss or system instability.
Back up project data immediately. Replace the CompactFlash card or HDD with a compatible unit. Restore the operating system image and HMI project from backup. - Temperature Warning
- The internal temperature sensor has detected that the Panel PC is operating above the recommended thermal threshold.
Check that ventilation slots are not blocked. Verify ambient temperature is within the 0 °C to +45 °C operating range. Clean any dust from ventilation areas and ensure adequate airflow around the unit. - Power Supply Fault
- The 24 V DC supply voltage has dropped below the minimum operating threshold, causing unstable operation or shutdown.
Measure the supply voltage at the power input connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance. Check wiring and connectors for loose contacts or corrosion.
Frequently Asked Questions
What operating system does the 6AV7613-0AA10-0AF0 run?
The SIMATIC Panel PC 670 6AV7613-0AA10-0AF0 is designed to run Windows XP Embedded or Windows 2000, providing compatibility with Siemens WinCC and ProTool HMI software.
What is the display size and resolution of this Panel PC?
This unit features a 12-inch TFT color LCD display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen input.
What is the supply voltage for the 6AV7613-0AA10-0AF0?
The Panel PC operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in automation environments.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45) for network and PLC communication, as well as RS-232 and RS-422/485 serial interfaces for legacy device connectivity.
What is the front panel protection rating of this device?
The front panel of the 6AV7613-0AA10-0AF0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for panel-flush mounting in industrial enclosures.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the power input connector. Verify the display backlight is functioning by shining a light at the screen to check for a faint image. Inspect internal fuses if accessible.
If supply voltage is correct but display is blank, the backlight inverter or CCFL backlight lamp may have failed. Replace the backlight assembly or the display unit. If no voltage is present, check the external power supply and wiring.
Touch screen does not respond or is inaccurate
Attempt to operate the unit using a connected USB keyboard or mouse to determine if the issue is isolated to the touch screen. Check Device Manager in Windows for touch controller errors.
Recalibrate the touch screen using the Windows calibration utility found in the Control Panel. If calibration does not resolve the issue, clean the touch surface and check the touch controller ribbon cable connection. Replace the touch screen assembly if the controller is faulty.
Panel PC fails to boot or continuously restarts
Observe the boot sequence for error messages. Check the CompactFlash card or HDD for errors using a bootable diagnostic tool. Listen for unusual sounds from the storage device.
Replace the CompactFlash card or hard disk drive with a compatible unit. Restore the operating system image and HMI project from a verified backup. Ensure the BIOS boot order is correctly configured to boot from the primary storage device.
Loss of communication with PLC
Verify the Ethernet or serial cable is securely connected at both ends. Ping the PLC IP address from the Panel PC command prompt to test network connectivity. Check the WinCC or ProTool communication driver status.
Correct any IP address conflicts or subnet mismatches. Replace damaged cables. Restart the communication driver or the entire HMI runtime application. If using a serial connection, verify baud rate, parity, and stop bit settings match the PLC configuration.
System runs slowly or HMI application freezes
Open Windows Task Manager to check CPU and memory utilization. Identify any background processes consuming excessive resources. Check available storage space on the system drive.
Disable unnecessary startup programs and background services. Free up storage space by removing unused files. If the CompactFlash card or HDD is nearly full or degraded, replace it and restore a clean system image. Consider increasing virtual memory settings if RAM is insufficient.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page



