Siemens 6AV7612-0AF32-0BG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AF32-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a high-performance computing platform with an integrated flat-panel display, providing a compact all-in-one solution for process visualization and control.
The SIMATIC Panel PC 670 6AV7612-0AF32-0BG0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and touch screen capability for operator interaction. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP or Windows CE, supporting SIMATIC WinCC flexible and other Siemens HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), enabling integration with SIMATIC S7 PLCs and other automation systems via PROFIBUS or Industrial Ethernet. The front panel meets IP65 protection rating, making it suitable for installation in control cabinet doors exposed to dust and water spray.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process industries, and machine building applications where a robust, panel-mounted PC with visualization software is required. It is commonly found in automotive production lines, food and beverage processing plants, chemical facilities, and packaging machinery. Its fanless or low-noise design options and industrial-grade components make it suitable for continuous 24-hour operation in harsh industrial environments.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front panel) |
| Communication Interface | Ethernet (RJ45), USB, RS-232, RS-422/RS-485 |
| Bus System Compatibility | PROFIBUS, Industrial Ethernet |
| Operating System | Windows XP Professional / Windows XP Embedded |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup error or boot failure detected on the Panel PC.
Check the hard disk or CompactFlash card for integrity. Verify the OS installation and re-image the storage medium if necessary. - Event ID: 200
- Communication loss to the PLC or SCADA system via configured interface.
Check Ethernet or PROFIBUS cable connections, verify IP address configuration, and confirm PLC is online and reachable. - Event ID: 300
- WinCC flexible runtime application has terminated unexpectedly.
Check the WinCC flexible project for configuration errors, review Windows event logs, and restart the runtime application. Reinstall if the issue persists. - Event ID: 400
- Touchscreen calibration error or touch input not responding correctly.
Recalibrate the touchscreen via the Windows control panel or SIMATIC Touchscreen Calibration tool. Check the touch controller connection internally. - Event ID: 500
- Internal temperature warning — Panel PC operating temperature exceeded threshold.
Check ambient temperature and ventilation around the panel. Clean any air vents or filters. Verify that the cooling fan (if fitted) is operational. - Event ID: 600
- Storage medium error — hard disk or CompactFlash card read/write failure.
Run a disk check utility. Back up project data immediately and replace the storage medium if errors persist. - Event ID: 700
- Power supply voltage out of range — 24 V DC supply is below or above acceptable limits.
Measure the 24 V DC supply at the panel connector. Ensure the power supply unit is within tolerance (typically 18–30 V DC) and check wiring connections.
Frequently Asked Questions
What display size and resolution does the 6AV7612-0AF32-0BG0 have?
This Panel PC features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen for operator input.
What operating system does the SIMATIC Panel PC 670 6AV7612-0AF32-0BG0 run?
This unit runs Microsoft Windows XP Professional or Windows XP Embedded, and is compatible with SIMATIC WinCC flexible for HMI visualization projects.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and serial interfaces (RS-232 and RS-422/RS-485), supporting connectivity to SIMATIC S7 PLCs via Industrial Ethernet or PROFIBUS.
What is the IP protection rating of the 6AV7612-0AF32-0BG0?
The front panel of this unit is rated IP65, providing protection against dust ingress and water jets, making it suitable for mounting in control cabinet doors in industrial environments.
What is the supply voltage required for this Panel PC?
The SIMATIC Panel PC 670 6AV7612-0AF32-0BG0 operates on a 24 V DC supply voltage, which is standard for SIMATIC panel-mounted devices.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the panel connector using a multimeter. Verify that the power LED indicator is illuminated. Check internal fuse if accessible.
Ensure the 24 V DC supply is within the 18–30 V DC tolerance range. Replace the internal fuse if blown. If the backlight is faulty, the backlight inverter or display assembly may need replacement.
Touchscreen does not respond or registers incorrect touch positions
Attempt to interact with the touchscreen and observe if any response is registered. Access the Windows control panel to check touch controller status.
Recalibrate the touchscreen using the SIMATIC Touchscreen Calibration utility or Windows Pointer Device settings. If calibration fails, check the internal ribbon cable connection between the touch panel and the controller board.
Panel PC fails to boot or continuously restarts
Observe the boot sequence on the display. Check Windows event logs if the OS partially loads. Test the CompactFlash card or hard disk in another system to verify integrity.
Re-image the storage medium with a valid OS and WinCC flexible installation. Replace the CompactFlash card or hard disk if it is found to be faulty.
Loss of communication with SIMATIC S7 PLC
Verify the Ethernet or PROFIBUS cable is securely connected. Ping the PLC IP address from the Panel PC command prompt. Check the WinCC flexible communication driver configuration.
Correct any IP address or subnet mask mismatches. Replace the communication cable if damaged. Reconfigure the communication driver in WinCC flexible if settings have been lost.
Panel PC overheating or thermal shutdown
Check the ambient temperature around the panel installation. Inspect ventilation slots for blockage. If the unit has a cooling fan, verify it is spinning.
Improve cabinet ventilation or add active cooling. Clean dust from ventilation openings. If the internal fan has failed, replace it. Ensure the Panel PC is not installed in an environment exceeding 45 °C ambient temperature.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page