Siemens 6AV7612-0AF30-0CE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AF30-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling complex SCADA, process visualization, and control applications.
The SIMATIC Panel PC 670 6AV7612-0AF30-0CE0 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and a touch-sensitive screen for operator interaction. It is equipped with an Intel processor, supports Windows-based operating systems, and provides multiple communication interfaces including Ethernet (RJ45) and serial ports (RS-232). The unit is designed for panel mounting with a robust aluminum front frame rated to IP65 on the front side, ensuring protection against dust and water ingress in industrial environments. Expansion options include PCI slots and USB ports for peripheral connectivity.
The SIMATIC Panel PC 670 is widely used in the automotive, food and beverage, chemical, and manufacturing industries where a full PC platform is required at the machine level. Its compatibility with Siemens SIMATIC WinCC and other SCADA software makes it suitable for process visualization, data logging, and recipe management. The fanless or low-noise cooling design options make it appropriate for environments where maintenance access is limited and long-term reliability is critical.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 px (XGA) |
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 90 W |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Watchdog timeout triggered — the application or OS did not respond within the defined watchdog interval.
Restart the Panel PC. Check the running application for software hangs. Reconfigure watchdog timeout settings if necessary. - Event ID: 300
- Fan failure or thermal overtemperature condition detected.
Check cooling fan operation and clean air vents. Verify ambient temperature is within specification (0 to +45 °C). Replace fan module if defective. - Event ID: 400
- UPS (uninterruptible power supply) module fault or battery low condition.
Check UPS module connection and battery charge level. Replace UPS battery if capacity is below threshold. - Event ID: 500
- Ethernet communication link failure — no network connection detected.
Check Ethernet cable and switch/hub connection. Verify IP address configuration in the operating system. Replace Ethernet cable or network adapter if fault persists. - Event ID: 600
- Touchscreen calibration error or touch input not responding correctly.
Recalibrate the touchscreen using the Siemens calibration utility in the control panel. If calibration fails, check touchscreen controller connection or replace the touch overlay. - Event ID: 700
- Application software (e.g. WinCC) runtime error or unexpected termination.
Check WinCC or SCADA application logs for error details. Reinstall or repair the runtime software. Verify hardware compatibility and available system resources.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AF30-0CE0?
The SIMATIC Panel PC 670 6AV7612-0AF30-0CE0 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
What display size and resolution does this Panel PC have?
This unit features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA), suitable for detailed process visualization and SCADA graphics.
Is the 6AV7612-0AF30-0CE0 compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens SIMATIC WinCC and other Windows-based HMI and SCADA software packages.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AF30-0CE0 is rated to IP65, providing full protection against dust and low-pressure water jets.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), RS-232 serial ports, and USB interfaces, enabling connectivity to PLCs, networks, and peripheral devices.
Troubleshooting
Display remains blank after power on
Measure 24 V DC supply voltage at the power input connector. Check the internal fuse and verify the power supply unit output. Confirm the display backlight is not failed.
Replace the internal fuse if blown. If supply voltage is correct but display remains off, replace the backlight inverter or the TFT display panel assembly.
Touchscreen does not respond or registers incorrect touch positions
Check if the touchscreen calibration has been lost, which can occur after an OS reinstall or BIOS reset. Verify the touchscreen controller driver is installed correctly.
Run the Siemens touchscreen calibration utility from the Windows control panel. If calibration does not resolve the issue, inspect the touch overlay ribbon cable connection and replace the touch overlay if damaged.
Panel PC fails to boot or shows BIOS error on startup
Check the CompactFlash card or hard disk drive for errors using a diagnostic tool. Verify BIOS settings have not been reset to incompatible defaults.
Reseat the storage media and attempt to boot again. If the storage device is corrupted, restore the operating system image using the Siemens recovery media. Replace the storage device if hardware failure is confirmed.
Ethernet communication is not established with the PLC or network
Check the Ethernet cable connection and verify the link LED on the RJ45 port is active. Confirm the IP address and subnet mask settings in the Windows network configuration.
Replace the Ethernet cable if damaged. Reconfigure the network settings to match the plant network. If the network adapter is faulty, replace the Ethernet interface card or the main board.
Panel PC overheats and shuts down unexpectedly
Check ambient temperature around the panel installation. Inspect cooling vents and fans for dust blockage. Verify the fan is operating correctly.
Clean all cooling vents and fan assemblies with compressed air. Ensure the panel enclosure provides adequate ventilation and that ambient temperature does not exceed 45 °C. Replace the cooling fan if it is not spinning.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page