Siemens 6AV7612-0AF30-0AF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AF30-0AF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a high-performance computing platform with an integrated flat-panel display, providing a compact all-in-one solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AF30-0AF0) features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and touch screen capability, enabling intuitive operator interaction. It is equipped with an Intel processor platform, supports Windows-based operating systems, and provides multiple communication interfaces including Ethernet (RJ45) and serial ports (COM). The unit offers PCI expansion slots for additional interface cards, USB ports for peripheral connectivity, and is built with an industrial-grade fanless or fan-cooled design depending on configuration, ensuring reliable operation in harsh industrial environments.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, chemical processing, and energy industries where a robust, PC-based HMI solution is required. It is suitable for integration with Siemens SIMATIC WinCC, WinCC flexible, and other SCADA or visualization software packages. Its panel-mount form factor and IP65-rated front panel make it appropriate for direct installation into control cabinets and operator stations on the factory floor.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Communication Interfaces | Ethernet (RJ45), 2x COM (RS-232), USB |
| Expansion | PCI slot |
| Mounting | Panel mount |
| Certifications | CE, UL |
| Series | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify OS installation. Replace storage medium if faulty. - Event ID: 200
- Fan failure or thermal warning — internal temperature has exceeded safe operating threshold.
Check and clean cooling fans and ventilation openings. Verify ambient temperature is within specification (0–45 °C). Replace fan unit if defective. - Event ID: 300
- Touchscreen calibration error — touch input not responding correctly or is misaligned.
Recalibrate the touchscreen via the Windows control panel or SIMATIC touchscreen calibration utility. If persistent, check touchscreen controller connections. - Event ID: 400
- Ethernet communication failure — network interface not detected or link not established.
Check Ethernet cable and switch connection. Verify network adapter settings in Device Manager. Replace Ethernet card or check onboard NIC if fault persists. - Event ID: 500
- Hard disk or storage device not found during boot sequence.
Check physical connection of HDD or CompactFlash card. Replace storage device if undetected. Restore OS image from backup. - Event ID: 600
- Power supply voltage out of range — 24 V DC supply is outside acceptable tolerance.
Measure supply voltage at the input connector. Ensure supply is within 20.4–28.8 V DC. Check wiring and power supply unit output. - Event ID: 700
- WinCC Runtime or HMI application has terminated unexpectedly.
Check Windows Event Viewer for application error details. Reinstall or repair WinCC Runtime. Verify project configuration and available system memory.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AF30-0AF0?
The SIMATIC Panel PC 670 (6AV7612-0AF30-0AF0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
What operating system does this Panel PC support?
The SIMATIC Panel PC 670 supports Windows XP Professional or Windows XP Embedded, depending on the ordered configuration. It is compatible with Siemens SIMATIC WinCC and WinCC flexible visualization software.
What is the IP protection rating of the 6AV7612-0AF30-0AF0?
The front panel of the 6AV7612-0AF30-0AF0 is rated IP65, providing protection against dust and water jets. The rear of the unit is rated IP20.
Can this Panel PC be used with Siemens WinCC SCADA software?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC, WinCC flexible, and other PC-based HMI and SCADA applications, making it a standard platform for Siemens visualization solutions.
Does the 6AV7612-0AF30-0AF0 have expansion slots?
Yes, the SIMATIC Panel PC 670 includes at least one PCI expansion slot, allowing additional interface cards such as PROFIBUS or serial communication cards to be installed.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the input connector using a multimeter. Verify the power LED status. Inspect internal fuses and the backlight inverter board.
Ensure the supply voltage is within 20.4–28.8 V DC. Replace the backlight inverter or CCFL backlight lamp if the display is not illuminating. Check and replace internal fuses if blown.
Touchscreen does not respond or responds inaccurately
Attempt to operate the unit using a connected USB mouse to determine if the issue is isolated to the touchscreen. Check Device Manager for touchscreen controller errors.
Recalibrate the touchscreen using the Windows calibration tool or Siemens SIMATIC calibration utility. If calibration fails, check the touchscreen ribbon cable connection. Replace the touchscreen overlay if physically damaged.
Panel PC fails to boot and shows a black screen or BIOS error
Listen for POST beep codes and note any error messages displayed during startup. Check if the hard disk or CompactFlash storage device is detected in BIOS.
Reseat the storage device and memory modules. If the HDD or CompactFlash card is not detected, replace it and restore the OS image. Reset BIOS settings to default if configuration has been corrupted.
Ethernet communication is not functioning
Check the Ethernet port LED indicators for link activity. Verify cable connections and switch port status. Open Device Manager to check for network adapter errors or driver issues.
Replace the Ethernet cable and test with a known-good network port. Reinstall network adapter drivers if shown as faulty in Device Manager. If the onboard NIC is defective, install a PCI Ethernet card as a replacement.
WinCC Runtime application crashes or freezes during operation
Review the Windows Event Viewer application and system logs for error codes or exception messages. Check available RAM and CPU usage during the fault condition.
Ensure sufficient free disk space and RAM are available. Reinstall or repair the WinCC Runtime installation. Verify the HMI project configuration for errors. If hardware resources are insufficient, consider upgrading RAM or optimizing the project.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page