Siemens 6AV7612-0AF22-0CF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AF22-0CF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling it to run standard Windows-based SCADA and HMI software alongside process control applications.
The SIMATIC Panel PC 670 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology. It is powered by an Intel Celeron processor and supports standard PC interfaces including USB, serial (RS-232), and Ethernet (RJ45) for integration into industrial networks. The unit is designed for front-panel mounting with an IP65 protection rating on the front face, making it resistant to dust and water ingress in the operator area. It operates on a 24 V DC supply and is built to withstand the vibration and temperature conditions typical of industrial cabinets.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building where a full PC-based HMI solution is required. It is suitable for applications such as SCADA visualization, recipe management, data logging, and integration with Siemens SIMATIC S7 PLC families via PROFIBUS or Industrial Ethernet. Industries including automotive, food and beverage, chemical processing, and packaging commonly deploy this panel PC for operator workstation and supervisory control functions.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Mounting | Panel mounting (front flush) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Windows XP Professional / Windows 2000 |
Common Error Codes & System Events
- Event ID: 1000
- Application error – a software application on the Panel PC has crashed or terminated unexpectedly.
Check the Windows Event Viewer for details on the faulting application. Restart the application or reinstall the HMI software if the error persists. - Event ID: 7026
- A boot-start or system-start driver failed to load during Windows startup.
Check Device Manager for driver conflicts. Reinstall or update the relevant hardware driver. Verify hardware connections and reseat expansion cards if present. - Event ID: 6008
- The system was shut down unexpectedly – indicates an unclean shutdown or power loss.
Check the 24 V DC power supply for stability and voltage drops. Inspect UPS or power conditioning equipment. Review application logs for software-induced shutdowns. - BIOS POST Error
- The Panel PC fails to complete Power-On Self-Test, indicating a hardware fault such as failed RAM, CPU, or storage device.
Check and reseat memory modules. Verify that the CompactFlash card or hard disk is properly connected and not corrupted. Replace faulty hardware components as needed. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or field device via PROFIBUS or Industrial Ethernet.
Verify network cable connections and switch/hub status. Check IP address configuration and PROFIBUS station addresses. Confirm that the PLC is in RUN mode and the communication driver is correctly configured. - Watchdog Timeout
- The system watchdog has triggered, indicating the operating system or application has become unresponsive.
Investigate CPU load and running processes for resource exhaustion. Check for software loops or deadlocks in the HMI application. Restart the system and consider optimizing the application or upgrading memory. - Temperature Warning
- Internal temperature of the Panel PC has exceeded the recommended operating threshold.
Check that cabinet ventilation is adequate and ambient temperature is within specification. Clean air filters and cooling vents. Verify that the fan (if fitted) is operational.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AF22-0CF0?
The SIMATIC Panel PC 670 6AV7612-0AF22-0CF0 operates on a 24 V DC power supply. Ensure the supply is stable and within the specified tolerance range.
What is the display size and resolution of this Panel PC?
This unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen for operator input.
What communication interfaces are available on this Panel PC?
The 6AV7612-0AF22-0CF0 is equipped with Ethernet (RJ45), RS-232 serial, and USB interfaces, enabling connectivity to PLCs, networks, and peripheral devices.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, providing full dust protection and protection against water jets from any direction.
Is this Panel PC compatible with Siemens WinCC or SIMATIC HMI software?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC, WinCC flexible, and other SIMATIC HMI software packages under Windows XP Professional or Windows 2000.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector. Verify that the backlight is not simply dimmed via software settings. Inspect the internal fuse and power supply board.
Restore the correct 24 V DC supply. If the backlight has failed, replace the CCFL backlight or the display assembly. Replace the internal power supply module if no voltage is present at the mainboard.
Touchscreen does not respond or is inaccurate
Check if the touch controller is recognized in Windows Device Manager. Determine whether the issue is a calibration problem or a hardware failure by testing with a mouse.
Recalibrate the touchscreen using the Windows touchscreen calibration utility. If calibration does not resolve the issue, check the touch controller cable connection or replace the touchscreen overlay.
Panel PC fails to boot or hangs at BIOS screen
Check whether the CompactFlash card or hard disk is detected in BIOS. Listen for POST beep codes that indicate RAM or CPU faults. Reseat memory modules and storage devices.
Replace a corrupted or failed CompactFlash card or hard disk with a correctly imaged replacement. Reseat or replace RAM modules. If the mainboard is faulty, replace the Panel PC mainboard assembly.
Loss of communication with PLC over Industrial Ethernet
Verify the Ethernet cable and switch port are active. Check the IP address configuration in Windows Network Settings and in the HMI software communication driver. Ping the PLC from the Panel PC to test basic connectivity.
Correct any IP address conflicts or misconfiguration. Replace the Ethernet cable if damaged. Ensure the communication driver (e.g., SIMATIC NET) is correctly installed and configured with the right PLC connection parameters.
System runs slowly or HMI application freezes
Check CPU and RAM utilization in Windows Task Manager. Identify any background processes consuming excessive resources. Check the storage device for errors using disk diagnostic tools.
Close unnecessary background applications and disable non-essential startup programs. Defragment or replace the hard disk if storage performance has degraded. Consider increasing RAM if the system is consistently at capacity.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page