Siemens 6AV7612-0AE30-0BF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AE30-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface and visualization tasks in automation environments. The unit integrates a display, computing hardware, and industrial-grade I/O into a single compact enclosure suitable for direct panel installation.
The SIMATIC Panel PC 670 6AV7612-0AE30-0BF0 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation. It is powered by an Intel Celeron processor and runs Microsoft Windows operating systems, providing a full PC-based platform for SCADA, visualization, and data acquisition software such as Siemens WinCC. The unit offers standard PC interfaces including USB ports, serial COM ports, Ethernet (RJ45), and a PCI expansion slot for additional communication cards. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine building applications where a full PC-based HMI platform is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and discrete manufacturing. Its ruggedized design and compatibility with Siemens SIMATIC software make it a practical choice for integration into existing Siemens automation architectures.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Processor | Intel Celeron |
| Operating System | Microsoft Windows XP / Windows 2000 |
| Input/Operating Voltage | 24 V DC |
| Front Panel Protection Rating | IP65 |
| Communication Interface | Ethernet RJ45, USB, RS-232 (COM ports) |
| Expansion | 1 x PCI slot |
| Mounting | Panel mounting |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the Panel PC failed to complete the boot sequence correctly, often due to a corrupted OS installation or failed hardware component.
Check hard disk integrity, verify OS installation, and inspect RAM modules. Re-image the hard disk or compact flash card if necessary. - Event ID: 200
- Watchdog timeout — the system watchdog has detected that the application or OS has stopped responding within the defined time window.
Restart the Panel PC. Check for software hangs or infinite loops in the running application. Update or reinstall the HMI software if the issue persists. - Event ID: 300
- Fan failure warning — the system has detected that the CPU cooling fan is not operating within the expected speed range.
Inspect and clean the cooling fan. Replace the fan if it is not spinning or is running below rated speed to prevent thermal shutdown. - Event ID: 400
- Temperature warning — internal temperature has exceeded the defined threshold, risking thermal shutdown.
Check ambient temperature and ensure adequate ventilation around the panel. Clean air filters and verify that the cooling fan is operational. - Event ID: 500
- Hard disk or storage media error — the system has detected read/write errors on the primary storage device.
Run a disk diagnostic utility. Back up data immediately and replace the hard disk or compact flash card if errors are confirmed. - Event ID: 600
- Network communication error — the Ethernet interface has lost connection or failed to initialize.
Check Ethernet cable connections and network switch settings. Verify IP address configuration in the operating system network settings. - Event ID: 700
- Touch screen calibration error — the touch input is misaligned or unresponsive after a system restart.
Run the touch screen calibration utility from the Windows Control Panel or the Siemens Panel PC configuration tool. Clean the touch surface and recalibrate.
Frequently Asked Questions
What display size and resolution does the 6AV7612-0AE30-0BF0 have?
The unit features a 15-inch TFT color LCD with a resolution of 1024 x 768 pixels (XGA) and a resistive touch screen.
What operating system does the SIMATIC Panel PC 670 6AV7612-0AE30-0BF0 run?
This Panel PC is compatible with Microsoft Windows XP and Windows 2000, providing a full PC-based platform for industrial HMI and SCADA software.
What is the supply voltage for this Panel PC?
The 6AV7612-0AE30-0BF0 operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC products.
Is the 6AV7612-0AE30-0BF0 compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other SIMATIC HMI software packages, making it directly compatible with Siemens automation systems.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AE30-0BF0 meets IP65 protection, providing full protection against dust and resistance to water jets from any direction.
Troubleshooting
Panel PC does not boot or display remains blank after power on
Check that 24 V DC supply voltage is present at the power connector. Inspect the internal hard disk or compact flash card for signs of failure. Listen for POST beep codes during startup.
Verify and restore the 24 V DC supply. Re-image or replace the storage device with a correctly configured OS image. If the display remains blank, test with an external monitor via the VGA port to isolate a display fault.
Touch screen is unresponsive or input is misaligned
Determine whether the touch controller is recognized in the Windows Device Manager. Check if the touch surface is dirty or physically damaged.
Clean the touch screen surface with a soft cloth. Run the touch screen calibration utility from the Windows Control Panel. If the controller is not recognized, reinstall the touch screen driver or replace the touch screen assembly.
System overheating or unexpected shutdown due to high temperature
Check the ambient temperature around the panel and measure airflow. Inspect the CPU cooling fan for correct operation and check air filters for blockage.
Ensure the installation environment is within the 0 °C to +45 °C operating range. Clean or replace clogged air filters and replace a faulty cooling fan. Verify that ventilation clearances around the enclosure are maintained.
Ethernet communication is not working
Check the Ethernet cable and verify the link LED on the RJ45 port is active. Confirm IP address settings in the Windows network configuration. Test connectivity with a ping command.
Replace the Ethernet cable if faulty. Reconfigure the IP address and subnet mask to match the network. If the NIC is not detected in Device Manager, reinstall the network adapter driver or replace the Ethernet card.
Application software freezes or crashes repeatedly
Check Windows Event Viewer for application or system error logs. Monitor CPU and RAM usage to identify resource exhaustion. Verify that the storage device is functioning correctly with no disk errors.
Close unnecessary background applications to free system resources. Run a disk check utility to repair file system errors. Reinstall the HMI application software if corruption is suspected, and ensure the OS and drivers are up to date.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page