Siemens 6AV7612-0AE30-0AJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AE30-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC platform, offering the flexibility of a standard computing environment within a rugged industrial enclosure.
The SIMATIC Panel PC 670 (6AV7612-0AE30-0AJ0) features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation. It is equipped with an Intel Celeron or Pentium M processor depending on the configuration, and supports standard PC interfaces including USB, Ethernet (RJ45), and serial COM ports. The unit runs on Microsoft Windows operating systems and is compatible with Siemens WinCC and SIMATIC software environments, enabling seamless integration into Siemens automation architectures. The front panel is designed to IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, automotive production, and machine tool industries where a full PC-based HMI solution is required. Its compatibility with standard industrial software and Siemens SIMATIC systems makes it suitable for SCADA, data logging, recipe management, and complex visualization applications. The robust construction and industrial-grade components ensure reliable operation in environments with vibration, temperature variation, and electromagnetic interference.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Type | TFT LCD |
| Touch Technology | Resistive touch screen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP/Protection Rating | IP65 (front panel) |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM) |
| Operating System | Windows XP / Windows 2000 |
| Series/Product Family | SIMATIC Panel PC 670 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- System startup failure – the Panel PC fails to complete the boot sequence, often due to a corrupted operating system or failed storage device.
Check the CompactFlash card or hard disk for errors. Reinstall the operating system if necessary and verify all hardware connections. - Event ID: 1000
- Application error – a software application running on the Panel PC has crashed or become unresponsive.
Restart the application. Check the Windows Event Viewer for detailed error logs and update or reinstall the affected software. - Event ID: 7000
- Service failed to start – a required Windows service did not start during boot, which may affect HMI functionality.
Open Windows Services manager, locate the failed service, and attempt a manual start. Check for dependency services and repair or reinstall if needed. - WinCC Runtime Error
- WinCC Runtime has encountered a configuration or communication error and cannot establish a connection to the PLC or data source.
Verify the communication settings in WinCC, check the network connection to the PLC, and ensure the correct driver is installed and configured. - Hardware Watchdog Timeout
- The hardware watchdog timer has triggered a system reset due to the operating system or application becoming unresponsive.
Investigate software processes causing high CPU load. Check for memory leaks or runaway processes and optimize the application configuration. - Temperature Warning
- The internal temperature of the Panel PC has exceeded the recommended operating threshold, risking hardware damage.
Check that ventilation slots are unobstructed, verify ambient temperature is within specification, and inspect internal fans or cooling elements if present. - Drive Error / Storage Fault
- The CompactFlash card or hard disk drive has reported a read/write error or is not detected by the system.
Replace the CompactFlash card or hard disk. Restore the operating system and application software from a backup image.
Frequently Asked Questions
What is the display size and resolution of the 6AV7612-0AE30-0AJ0?
The SIMATIC Panel PC 670 (6AV7612-0AE30-0AJ0) features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA).
What operating system does the 6AV7612-0AE30-0AJ0 support?
This Panel PC supports Microsoft Windows XP Professional and Windows 2000, and is compatible with Siemens WinCC and SIMATIC HMI software.
What is the supply voltage for the SIMATIC Panel PC 670?
The unit operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in automation environments.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7612-0AE30-0AJ0 is rated to IP65, providing protection against dust and low-pressure water jets.
Is the 6AV7612-0AE30-0AJ0 compatible with Siemens S7 PLCs?
Yes, this Panel PC is compatible with Siemens S7-300 and S7-400 PLCs via Ethernet or PROFIBUS communication, using WinCC or STEP 7 software for integration.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the power LED status and listen for system boot activity such as fan spin-up.
If supply voltage is correct but display remains blank, check the backlight inverter and display cable connections internally. Replace the backlight or display assembly if the inverter is faulty.
Touch screen does not respond or is inaccurate
Verify that the touch screen driver is correctly installed in the operating system. Check for physical damage or contamination on the screen surface.
Recalibrate the touch screen using the Windows control panel or Siemens calibration utility. If calibration fails, replace the touch screen overlay or the touch controller board.
Panel PC fails to boot or continuously restarts
Attempt to boot from an external USB device to isolate whether the issue is with the internal storage (CompactFlash or HDD) or the motherboard.
Replace the CompactFlash card or hard disk drive and restore the operating system from a backup image. If the issue persists, inspect the motherboard for failed capacitors or damaged components.
Loss of communication with PLC or SCADA system
Check the Ethernet cable and network switch connection. Verify the IP address configuration in Windows and confirm the WinCC communication driver settings.
Restore correct IP settings, replace the Ethernet cable if faulty, and restart the WinCC Runtime application. Update the communication driver if an incompatibility is detected.
System runs slowly or application freezes
Check CPU and memory usage in Windows Task Manager. Identify any processes consuming excessive resources and check available storage space on the system drive.
Close unnecessary background applications, increase virtual memory if RAM is insufficient, and defragment or replace the storage device. Consider upgrading the CompactFlash card to a higher-speed model.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page