• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AE22-0BG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AE22-0BG0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AE22-0BG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AE22-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface applications, combining a built-in display with a full PC architecture running a Windows-based operating system. The unit is intended for use as an operator station in industrial environments where both visualization and computing power are required.

    The SIMATIC Panel PC 670 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), providing clear visualization of process data and HMI graphics. It is equipped with an Intel Celeron processor and supports standard PC interfaces including USB, Ethernet (RJ45), and serial COM ports for connectivity to PLCs and peripheral devices. The unit is designed for panel mounting with a robust aluminum front frame rated to IP65 on the front side, ensuring protection against dust and water ingress in industrial settings. It supports Siemens WinCC flexible and SIMATIC WinCC runtime software for HMI and SCADA applications.

    The SIMATIC Panel PC 670 is widely deployed in manufacturing automation, process control, and machine tool industries where a full PC platform is required alongside operator interface functionality. Its compatibility with Siemens SIMATIC software ecosystems makes it suitable for integration into S7-300 and S7-400 PLC environments. Typical applications include supervisory control stations, production line monitoring, and complex visualization tasks that exceed the capabilities of standard operator panels.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT Color LCD
    Display Colors 256,000 colors
    Front Protection Rating IP65
    Rear Protection Rating IP20
    Operating Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), USB, Serial (COM)
    Mounting Panel mounting
    Operating System Windows XP Embedded
    Certifications CE, UL

    Common Error Codes and System Events

    Event ID: 1000
    Application error in WinCC Runtime — the runtime process has terminated unexpectedly.
    Check Windows Event Viewer for details. Reinstall or repair the WinCC Runtime software. Verify hardware resources are sufficient.
    Event ID: 26
    Application popup — a system application has encountered an error and requires user interaction to continue.
    Acknowledge the popup dialog. If recurring, check for software conflicts or corrupted runtime files and reinstall the affected application.
    BSOD: 0x0000007B
    Inaccessible boot device — the operating system cannot access the boot storage device during startup.
    Check the CompactFlash card or hard disk connection. Replace the storage medium if faulty. Restore the OS image using the Siemens recovery tool.
    BSOD: 0x00000050
    Page fault in non-paged area — a memory access violation has occurred, often related to faulty RAM or driver issues.
    Reseat or replace RAM modules. Update or roll back recently installed drivers. Run a memory diagnostic utility.
    WinCC RT: Connection Error
    WinCC Runtime cannot establish a connection to the configured PLC or communication driver.
    Verify Ethernet or MPI/PROFIBUS cable connections. Check PLC address configuration in WinCC project. Ensure the correct communication driver is installed and active.
    WinCC RT: License Error
    A valid WinCC Runtime license is not found or has expired, preventing full runtime operation.
    Check the license dongle or software license using Siemens Automation License Manager. Transfer or reactivate the appropriate WinCC Runtime license.
    POST Error: Memory Test Failure
    The BIOS power-on self-test has detected a memory fault during system startup.
    Reseat RAM modules. If the error persists, replace the faulty RAM module with a compatible replacement specified for the Panel PC 670.
    Watchdog Timeout
    The system watchdog timer has triggered a reset because the operating system or application became unresponsive.
    Investigate CPU load and running processes. Optimize or reduce the load on the WinCC Runtime application. Check for software loops or memory leaks in the HMI project.

    Frequently Asked Questions

    What operating system does the 6AV7612-0AE22-0BG0 run?

    The SIMATIC Panel PC 670 6AV7612-0AE22-0BG0 runs Windows XP Embedded as its operating system, which is pre-installed and optimized for industrial HMI use.

    What HMI software is compatible with this Panel PC?

    The unit is compatible with Siemens SIMATIC WinCC flexible and SIMATIC WinCC Runtime software. It can also run other Windows-compatible SCADA and visualization applications.

    What is the display size and resolution of this unit?

    The panel features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).

    What is the front panel protection rating?

    The front panel of the 6AV7612-0AE22-0BG0 is rated to IP65, providing full protection against dust and resistance to water jets.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), USB ports, and serial COM ports, enabling connectivity to PLCs, barcode scanners, printers, and other industrial peripherals.

    Troubleshooting

    Panel PC does not boot and display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the CompactFlash card or hard disk is properly seated. Listen for POST beep codes that may indicate a hardware fault.

    Ensure the 24 V DC supply is within tolerance. Reseat the storage medium. If the OS is corrupted, restore the factory image using the Siemens recovery utility on a bootable USB or CD.

    WinCC Runtime fails to start or crashes repeatedly

    Check the Windows Event Viewer for application error logs. Verify that a valid WinCC Runtime license is present using the Automation License Manager. Check available disk space and RAM.

    Reinstall or repair the WinCC Runtime installation. Reactivate the software license if missing. Free up disk space and ensure no conflicting background applications are consuming excessive resources.

    Touchscreen does not respond or is inaccurate

    Check for physical damage or contamination on the touchscreen surface. Verify the touchscreen driver is installed correctly in Device Manager. Attempt a touchscreen recalibration via the Windows control panel.

    Clean the touchscreen surface with a soft, dry cloth. Recalibrate the touch input using the calibration utility. If unresponsive after recalibration, the touchscreen overlay may require replacement.

    No communication between Panel PC and PLC

    Verify the Ethernet or serial cable connection between the Panel PC and the PLC. Check the IP address configuration on both devices. Confirm the correct communication driver is active in WinCC.

    Replace or reseat the communication cable. Align the IP address and subnet settings on both the Panel PC and PLC. Reinstall the appropriate Siemens communication driver if it is missing or corrupted.

    System runs slowly or HMI graphics are sluggish

    Check CPU and RAM utilization in Windows Task Manager. Identify any background processes consuming excessive resources. Verify that the CompactFlash card or hard disk is not failing by checking for read/write errors.

    Disable unnecessary background services and startup programs. Optimize the WinCC project by reducing the number of simultaneous animations or data points. Replace the storage medium if disk errors are detected.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart