Siemens 6AV7612-0AE22-0AG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AE22-0AG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, providing a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AE22-0AG0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation for intuitive operator interaction. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, providing compatibility with standard SCADA and HMI software packages including Siemens WinCC. The unit offers multiple communication interfaces including Ethernet (RJ45) and serial ports, and is built to meet industrial environmental requirements with a front panel protection rating of IP65.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building applications where a reliable, PC-based visualization platform is required. It is suitable for installation in control cabinets and operator panels in industries such as automotive, food and beverage, chemical processing, and water treatment. Its fanless or low-maintenance design options and industrial-grade components make it appropriate for continuous operation in environments with elevated temperatures, vibration, and dust.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Communication Interface | Ethernet (RJ45), RS-232, RS-422/485 |
| Operating System | Windows XP Professional / Windows 2000 |
| Processor | Intel Celeron |
| Mounting | Panel mounting |
| Certifications | CE, UL |
Common Error Codes and System Events
- Event ID: 1000
- Application error in the operating system or HMI runtime software has caused an unexpected termination.
Check Windows Event Viewer for details. Reinstall or repair the HMI runtime software (e.g. WinCC flexible). Ensure all software patches are applied. - Event ID: 7000
- A system service failed to start during Windows boot sequence.
Check Windows Event Viewer under System logs. Verify that all required services are enabled and set to automatic start. Reinstall drivers if necessary. - BIOS POST Error
- Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
Reseat RAM modules and CompactFlash or hard disk connections. Verify hardware compatibility. Replace faulty components as needed. - WinCC Runtime Error
- WinCC or WinCC flexible runtime fails to start or crashes during operation, often due to corrupted project files or licensing issues.
Verify the WinCC license is valid and installed. Restore the project from a backup. Reinstall WinCC runtime if the issue persists. - Network Connection Lost
- Ethernet communication to the PLC or network has been interrupted, causing loss of process data on the display.
Check Ethernet cable and switch connections. Verify IP address configuration. Check PLC communication settings and ensure the PLC is in RUN mode. - Touchscreen Calibration Error
- Touch input is misaligned or unresponsive, indicating a calibration drift or touchscreen controller fault.
Run the touchscreen calibration utility from the Windows Control Panel or SIMATIC startup menu. If unresponsive, check the touchscreen controller connection internally or replace the touchscreen assembly. - Storage Device Failure
- CompactFlash card or hard disk drive is not detected or has read/write errors, preventing the OS or project from loading.
Replace the CompactFlash card or hard disk drive. Restore the operating system image and HMI project from a backup. Ensure the replacement storage device meets Siemens specifications.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AE22-0AG0?
The SIMATIC Panel PC 670 (6AV7612-0AE22-0AG0) operates on a 24 V DC supply voltage, which is standard for industrial panel PCs in this series.
What operating system does this Panel PC run?
This unit is compatible with Windows XP Professional and Windows 2000, and supports Siemens WinCC and WinCC flexible HMI software for visualization applications.
What is the front panel protection rating of this device?
The front panel of the 6AV7612-0AE22-0AG0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for installation in control panels exposed to industrial environments.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45) for network and PLC communication, as well as RS-232 and RS-422/485 serial interfaces for connecting to legacy devices and controllers.
Is this Panel PC compatible with Siemens S7 PLCs?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens S7-300 and S7-400 PLCs via Ethernet or PROFIBUS communication, when configured with appropriate WinCC or WinCC flexible projects.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power input connector to confirm correct voltage level. Check for blown internal fuses or a faulty power supply module.
Replace any blown fuses with the correct rating. If the internal power supply module is faulty, replace it. Ensure the 24 V DC supply can deliver sufficient current for the unit.
Display is blank but the PC appears to be running (HDD activity, network active)
Check the display backlight by shining a light at the screen to see if an image is faintly visible. The backlight inverter or CCFL backlight lamp may have failed.
Replace the CCFL backlight lamp or the backlight inverter board. If the TFT panel itself is damaged, replace the complete display assembly with a compatible unit.
Touchscreen does not respond or registers incorrect touch positions
Attempt to recalibrate the touchscreen using the Windows Control Panel calibration tool. Check the internal ribbon cable connection between the touchscreen overlay and the controller board.
Perform a full touchscreen recalibration. If the issue persists, reseat or replace the touchscreen ribbon cable. Replace the touchscreen overlay or controller if hardware damage is confirmed.
System fails to boot and displays BIOS error or stops at POST screen
Check whether the CompactFlash card or hard disk is detected in the BIOS. Reseat the storage device and RAM modules. Listen for POST beep codes that indicate specific hardware faults.
Reseat all internal connectors and memory modules. Replace the CompactFlash card or hard disk if not detected. Restore the OS image from a Siemens recovery image or backup.
Loss of communication with the PLC during operation
Check the Ethernet or serial cable connections. Verify the IP address and subnet mask settings on the Panel PC match the network configuration. Check the PLC for communication faults.
Replace or reseat the communication cable. Reconfigure the network settings if they have been lost (e.g. after a CMOS battery failure). Ensure the PLC program and communication blocks are correctly configured.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page