Siemens 6AV7612-0AE20-0BJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AE20-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates computing hardware and a display into a single ruggedized enclosure suitable for direct panel installation.
The SIMATIC Panel PC 670 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation. It is built around an industrial-grade processor platform running Microsoft Windows, with onboard RAM and storage options suited for SCADA and HMI software such as Siemens WinCC. The unit provides communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces, enabling integration with PLCs and other automation components. The robust steel housing and fanless or low-noise cooling design contribute to reliable operation in industrial settings.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a powerful visualization platform is required. It is suitable for industries such as automotive, chemical processing, food and beverage, and energy, where operators need a reliable and capable HMI workstation integrated directly into the control panel. Its compatibility with standard PC software and Siemens automation software makes it a versatile platform for complex visualization and data acquisition tasks.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 px (XGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| IP Rating (Front) | IP65 |
| Mounting | Panel mounting |
| Communication Interface | Ethernet (RJ45), USB, RS-232 |
| Operating System | Microsoft Windows XP / Windows 2000 |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check the storage medium (CompactFlash or hard disk) for integrity. Reinstall or restore the operating system image if corrupted. - Event ID: 101
- Hardware configuration mismatch detected between installed hardware and stored configuration.
Re-run the hardware configuration utility and ensure all installed components are correctly recognized. Check RAM and expansion cards. - Event ID: 200
- Watchdog timeout — the system did not respond within the expected time window.
Investigate running processes for hangs or excessive CPU load. Restart the Panel PC and check for software conflicts or memory leaks. - Event ID: 201
- Fan failure or thermal warning — internal temperature has exceeded the warning threshold.
Check ventilation around the panel cutout. Clean any air filters or vents. Verify fan operation if unit is fan-cooled. Ensure ambient temperature is within specification. - Event ID: 300
- Communication interface error — loss of communication on the Ethernet or serial interface.
Check cable connections and network configuration. Verify IP address settings and ensure the connected PLC or SCADA system is online. - Event ID: 400
- Storage device error — read/write failure on the internal CompactFlash card or hard disk.
Replace the CompactFlash card or hard disk drive. Restore the operating system and application software from a backup image. - Event ID: 500
- Touch screen calibration error — touch input is misaligned or not responding correctly.
Run the touch screen calibration utility from the Windows control panel. If calibration fails, check the touch controller connection internally or replace the touch overlay. - Event ID: 600
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance. Check wiring and connections.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AE20-0BJ0?
The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.
What operating system does this Panel PC support?
The 6AV7612-0AE20-0BJ0 supports Microsoft Windows XP Professional and Windows 2000, which are compatible with Siemens WinCC and other SIMATIC HMI software packages.
What is the display size and resolution of this unit?
The unit features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA format).
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other SIMATIC HMI visualization software, making it directly compatible with Siemens S7 PLC families.
What is the front panel protection rating of the 6AV7612-0AE20-0BJ0?
The front panel of the unit carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the supply is within tolerance and that the power LED or indicator shows the unit is receiving power.
If voltage is correct but display remains blank, attempt a hard reset by cycling power. If the issue persists, the internal power supply board or the display backlight inverter may require replacement.
Touch screen does not respond or responds inaccurately
Attempt to operate the unit using a connected USB keyboard or mouse to determine if the issue is isolated to the touch interface. Check Device Manager in Windows for touch controller errors.
Run the touch screen recalibration utility. If recalibration does not resolve the issue, check the internal ribbon cable connection between the touch overlay and the controller board, or replace the touch screen overlay.
Panel PC fails to boot or gets stuck during Windows startup
Connect an external monitor via the VGA port if available to observe boot messages. Check the CompactFlash card or hard disk for errors using a bootable diagnostic tool.
Restore the operating system from a backup image onto a new CompactFlash card or hard disk. Ensure all hardware components are firmly seated and that no expansion cards are causing conflicts.
Loss of communication with connected PLC or SCADA system
Verify Ethernet cable connections and check the network configuration (IP address, subnet mask, gateway) in Windows Network Settings. Use the ping command to test network connectivity.
Reconfigure the network settings if incorrect. Replace the Ethernet cable if damaged. If the onboard Ethernet port is faulty, install a USB-to-Ethernet adapter as a temporary measure and arrange for repair of the mainboard.
Unit overheating or shutting down unexpectedly
Check the ambient temperature around the panel installation. Inspect ventilation slots and any air filters for blockage. Monitor the CPU temperature using a system monitoring utility within Windows.
Ensure the installation environment is within the 0 to 45 degrees Celsius operating range. Clean ventilation paths and replace any clogged filters. If the unit uses a cooling fan, verify it is operating correctly and replace if faulty.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page