
Siemens 6AV7612-0AE20-0BG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AE20-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a high-performance computing platform with a robust flat-panel display in a single integrated housing suitable for control cabinet front-panel installation.
The SIMATIC Panel PC 670 6AV7612-0AE20-0BG0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides standard PC interfaces including USB, serial (COM), and Ethernet ports, enabling integration with SIMATIC S7 PLCs and other automation components via PROFIBUS or Industrial Ethernet. The fanless or low-noise design and industrial-grade components ensure reliable continuous operation in harsh environments.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full PC-based HMI platform is required. Its compact panel-mount form factor makes it suitable for integration into control panels in automotive, food and beverage, chemical, and general manufacturing industries. The ability to run standard Windows-based SCADA and HMI software makes it a flexible platform for complex visualization and data acquisition tasks.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| IP Rating (Front) | IP65 |
| Mounting | Panel mounting |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Microsoft Windows XP / Windows 2000 |
Common Error Codes and System Events
- Event ID: 1000
- Application error — a software application running on the Panel PC has encountered an unexpected fault and terminated.
Check the Windows Event Viewer for detailed error logs. Reinstall or update the affected HMI application (e.g. WinCC). Verify software compatibility with the installed OS version. - Event ID: 7000
- Service control manager error — a required Windows service failed to start during boot.
Check the Windows Event Viewer System log for the specific service name. Ensure all required SIMATIC software services are set to automatic startup. Reinstall the relevant software package if the service is corrupt. - BIOS POST Error
- Hardware fault detected during Power-On Self-Test, indicating a memory, CPU, or hardware component failure.
Reseat RAM modules and check all internal connections. If the error persists, identify the specific POST beep code or on-screen message and replace the faulty hardware component. - WinCC Runtime Error
- SIMATIC WinCC runtime has failed to start or has crashed, preventing HMI visualization from operating.
Restart the WinCC runtime application. Check WinCC diagnostic logs for root cause. Verify the project configuration and ensure the license dongle or software license is valid and present. - Network Connection Lost
- The Panel PC has lost communication with the PLC or network, causing the HMI to display connection fault indicators.
Check Ethernet cable connections and switch/hub status. Verify IP address configuration matches the network settings. Check PROFIBUS cable and connector integrity if using PROFIBUS communication. - Watchdog Timeout
- The system watchdog has triggered a reset due to the operating system or application becoming unresponsive.
Investigate CPU load and running processes for resource exhaustion. Check for software loops or memory leaks in the HMI application. Consider increasing watchdog timeout settings or optimizing the application. - Hard Disk Failure Warning
- The internal hard disk or CompactFlash storage device is reporting errors or has failed, risking data loss.
Back up all project data immediately. Run a disk check utility (chkdsk) to assess disk health. Replace the internal hard disk or CompactFlash card and restore the system image and project files.
Frequently Asked Questions
What display size and resolution does the 6AV7612-0AE20-0BG0 have?
This Panel PC features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA). It supports resistive touch screen input.
What operating system does the SIMATIC Panel PC 670 6AV7612-0AE20-0BG0 run?
The unit is designed to run Microsoft Windows XP or Windows 2000. It supports SIMATIC WinCC and other Siemens HMI and SCADA software packages.
What communication interfaces are available on this Panel PC?
The 6AV7612-0AE20-0BG0 provides Ethernet (RJ45), USB ports, and RS-232 serial (COM) interfaces. It can communicate with SIMATIC S7 PLCs via Industrial Ethernet or PROFIBUS using appropriate communication cards.
What is the supply voltage for this Panel PC?
The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in control cabinet installations.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AE20-0BG0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets when correctly installed in a panel cutout.
Troubleshooting
Display remains blank after power is applied
Check that 24 V DC is present at the power supply connector. Verify the power LED status. Measure voltage at the internal power supply output to determine if the issue is with the external supply or the internal power board.
Ensure the 24 V DC supply is within tolerance and correctly connected. If the internal power supply has failed, replace the power supply module. If the display backlight has failed, replace the backlight inverter or the display assembly.
Touch screen does not respond or responds inaccurately
Determine whether the issue is a hardware fault or a calibration problem by checking if the cursor moves on screen when the display is touched. Access the touch screen calibration utility via the Windows control panel.
Recalibrate the touch screen using the SIMATIC touch screen calibration tool or the Windows Pointer Device calibration utility. If the touch screen hardware is damaged or unresponsive after recalibration, replace the touch screen overlay or the complete display assembly.
Panel PC fails to boot and displays a BIOS error or stops at POST screen
Listen for BIOS beep codes and note any on-screen POST error messages. Reseat RAM modules and check that all internal connectors are secure. Check the hard disk or CompactFlash card for physical damage.
Reseat or replace RAM modules. If the hard disk or CompactFlash storage has failed, replace it and restore the system using a backup image. If the motherboard is faulty, replace the computing module or the complete unit.
WinCC HMI application loses communication with the PLC
Check the Ethernet or PROFIBUS connection between the Panel PC and the PLC. Verify IP address settings and subnet configuration in Windows Network Settings. Check WinCC channel diagnostics for specific communication error messages.
Replace or reseat the Ethernet cable and verify switch/hub operation. Correct any IP address or subnet mask mismatches. If using PROFIBUS, inspect the cable, connectors, and termination resistors. Restart the WinCC runtime and re-establish the connection.
System runs slowly or HMI application freezes periodically
Open Windows Task Manager to check CPU and RAM utilization. Identify any background processes consuming excessive resources. Check the hard disk for fragmentation or errors using Windows disk tools.
Close unnecessary background applications and disable non-essential Windows services. Run a disk defragmentation and error check on the hard disk. If RAM is insufficient, upgrade the memory if the hardware supports it. Consider replacing the hard disk with a CompactFlash or SSD solution for improved reliability and performance.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page



